• 제목/요약/키워드: Islanded System

검색결과 57건 처리시간 0.023초

독립형 10kW ESS의 레독스 플로우 배터리 초기 구동 전원 제어 (Initial Operating Power Control of Redox Flow Battery in Offgrid 10kW ESS)

  • 최중묵;송용희;최은석;은종목;이영진;한동화;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.390-391
    • /
    • 2013
  • This paper proposes advanced RFB PCS for islanded environment. To accommodate islanded system, power conditioning needs voltage control authority changing. RFB initial power generating method is proposed for the Islanded PCS. DC-link voltage control authority is changed to PV converter to bidirectional converter by proposed control logic. The control performance has been verified with hardware experiments.

  • PDF

RFB 용 Dual-Buck Inverter 전압제어 품질 향상에 관한 연구 (Analysis of voltage controller of Dual-Buck Inverter using Redox Flow Battery)

  • 최중묵;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.393-394
    • /
    • 2014
  • This paper proposes advanced RFB PCS for islanded environment. To accommodate islanded system, power conditioning needs voltage control authority changing. Dualbuck inverter topology is designed for the high efficiency. In order to reduce voltage error the repetitive controller is used in this paper. The control performance has been verified with computer simulation.

  • PDF

마이크로그리드용 2기의 TMS320F28335 기반 BESS 제어기 구현 및 Hardware-in-the-Loop Simulation 시스템을 이용한 제어 성능 테스트 (Implementation of Two TMS320F28335 based BESS Controllers for Microgrid and Control Performance Test in the Hardware-in-the-Loop Simulation System)

  • 김남대;유형준;김학만
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.559-564
    • /
    • 2014
  • A microgrid as a small scale power system is operated by the grid-connected mode and islanded mode. It is anticipated that the battery energy storage system (BESS) is able to be applied to the microgrid for stable power control, such as tie-line and smoothing control in the grid-connected mode and voltage and frequency control in the islanded mode. In this paper, a digital signal processor (DSP), Two BESS controllers based on TMS320F28335 of a microgrid are implemented and are tested to show control performance in the hardware-in-the loop simulation (HILS) system.

독립운전 마이크로그리드의 능동형 동기 투입 제어에 관한 연구 (Study on the Dynamic Synchronizing Control of An Islanded Microgrid)

  • 조창희;전진홍;김종율;권순만;김성신
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1112-1121
    • /
    • 2011
  • A microgrid is an aggregation of multiple distributed generators (DGs) such as renewable energy sources, conventional generators, and energy storage systems that provide both electric power and thermal energy. Generally, a microgrid operates in parallel with the main grid. However, there are cases in which a microgrid operates in islanded mode, or in a disconnected state. Islanded microgrid can change its operational mode to grid-connected operation by reconnection to the grid, which is referred to as synchronization. Generally, a single machine simply synchronizes with the grid using a synchronizer. However, the synchronization of microgrid that operate with multiple DGs and loads cannot be controlled by a traditional synchronizer, but needs to control multiple generators and energy storage systems in a coordinated way. This is not a simple job, considering that a microgrid consists of various power electronics-based DGs as well as alternator-based generators that produce power together. This paper introduces the results of research examining an active synchronizing control system that consists of the network-based coordinated control of multiple DGs. Consequently, it provides the microgrid with a deterministic and reliable reconnection to the grid. The proposed method is verified by using the test cases with the experimental setup of a microgrid pilot plant.

RTDS를 이용한 신재생에너지 기반 마이크로그리드 시뮬레이션 해석 (Simulation Analysis of a Renewable Energy Based Microgrid using RTDS)

  • 허세림;김경훈;이효근;황철상;박민원;유인근;박정도;이동영;이상진
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2190-2195
    • /
    • 2011
  • Due to enhanced demands on quality, security and reliability of the electric power energy system, a microgrid has become a subject of special interest. In this paper, output characteristics of energy storage system (ESS) with an electric double layer capacitor (EDLC) and battery energy storage system (BESS) of a renewable energy based microgrid were analyzed under grid-connected and islanded operation modes. The microgrid which consists of photovoltaic and wind power turbine generators, diesel generator, ESS with an EDLC, BESS and loads was modeled using real time digital simulator. The results present the effective control patterns of the microgrid system.

마이크로그리드의 운전모드를 고려한 자동발전제어시스템 (Automatic Generation Control System for Operation Mode in Microgrid)

  • 박중성;이학주;채우규;김주용;조진태
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.928-936
    • /
    • 2012
  • The microgrid concept assumes a cluster of loads and microsources operating as a single controllable system that provides a new paradigm for defining the operation of distributed generation. This system can be operated as both grid-connected mode and islanded mode. In other words, the microgrid can be operated to meet their special need; such as economics in steady state and local reliability in islanded mode due to the grid fault. This paper presents the AGC (Automatic Generation Control) method for microgrid with EMS (Energy Management System).

Distributed Secondary Voltage Control of Islanded Microgrids with Event-Triggered Scheme

  • Guo, Qian;Cai, Hui;Wang, Ying;Chen, Weimin
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1650-1657
    • /
    • 2017
  • In this study, the distributed secondary voltage control of islanded microgrids with multi-agent consensus algorithm is investigated. As an alternative to a time-triggered approach, an event-triggered scheme is proposed to reduce the communication load among inverter-based distributed generators (DGs). The proposed aperiodic control scheme reduced unnecessary utilization of limited network bandwidth without degrading control performance. By properly establishing a distributed triggering condition in DG local controller, each inverter is only required to send voltage information when its own event occurs. The compensation of voltage amplitude deviation can be realized, and redundant data exchange related to fixed high sampling rate can be avoided. Therefore, an efficient use of communication infrastructure can be realized, particularly when the system is operating in steady state. The effectiveness of the proposed scheme is verified by simulations on a microgrid test system.

Energy Management of a Grid-connected High Power Energy Recovery Battery Testing System

  • Zhang, Ke;Long, Bo;Yoo, Cheol-Jung;Noh, Hye-Min;Chang, Young-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.839-847
    • /
    • 2016
  • Energy recovery battery testing systems (ERBTS) have been widely used in battery manufactures. All the ERBTS are connected in parallel which forms a special and complicated micro-grid system, which has the shortcomings of low energy recovery efficiency, complex grid-connected control algorithms issues for islanded detection, and complicated power circuit topology issues. To solve those shortcomings, a DC micro-grid system is proposed, the released testing energy has the priority to be reutilized between various testing system within the local grid, Compared to conventional scheme, the proposed system has the merits of a simplified power circuit topology, no needs for synchronous control, and much higher testing efficiency. The testing energy can be cycle-used inside the local micro-grid. The additional energy can be recovered to AC-grid. Numerous experimental comparison results between conventional and proposed scheme are provided to demonstrate the validity and effectiveness of the proposed technique.

Utilization of Energy Storage System based on the Assessment of Area of Severity in Islanded Microgrid

  • Lee, Kyebyung;Yoon, Minhan;Park, Chang-Hyun;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.569-575
    • /
    • 2017
  • This paper proposes a method to utilize an energy storage system (ESS) based on the assessment of an area of severity (AOS) to voltage sag. The AOS is defined as a set of the fault positions that can cause voltage sags at many buses simultaneously. The assessment of AOS helps to determine an optimal location of ESS installation to minimize the expected sag frequency (ESF) at concerned buses. The ESS has the ability not only to play traditionally known roles but also to mitigate voltage sag impact on renewable energy sources (RES) in the islanded microgrid. Accordingly, using the proposed method the ESS has additional features to prevent the operation failure of RESs and improve the stability of the microgrid. In order to verify the presented method, a case study was conducted on the sample microgrid system that is modified from an IEEE 57-bus system.

마이크로그리드 환경에서 부하차단을 위한 다중 에이전트 시스템의 설계 및 구현 (Design and Implementation of Multi-Agent System for Load Shedding in Microgrid)

  • 임유진;김학만
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제1권3호
    • /
    • pp.125-132
    • /
    • 2012
  • 마이크로그리드(microgrid)의 독립적 운용방식(islanded operation mode)에서는 전력 공급량과 전력 수요량 사이의 균형을 맞추기 위하여 부하차단(load shedding) 기법이 사용된다. 기존의 부하차단 기법들은 부하의 요구량이 연속적인 값의 범위를 갖는다고 가정하였다. 그러나 일부 부하는 이산적인 정수 값을 사용하여 자신의 요구량을 나타낸다. 따라서 본 논문에서는 독립형 운용방식 환경에서 부하 요구량의 이산적인 특성을 고려한 부하차단 기법을 다중 에이전트 시스템을 이용하여 설계한다. 또한 시스템 구조, 에이전트 기능, 그리고 에이전트 간 통신 프로토콜을 추가로 정의 및 확장함으로써 시스템을 구현하였으며, 구현된 시스템을 기반으로 다양한 시나리오 환경에서의 실험을 통하여 그 성능을 증명하였다.