• Title/Summary/Keyword: Irradiation time

Search Result 1,443, Processing Time 0.031 seconds

Improvement of Quality Stability of Red Ginseng by Gamma Irradiation (홍삼의 품질안정성 향상을 위한 감마선의 이용)

  • 권중호;변명우;장석도;이광승
    • Food Science and Preservation
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • Commercial red ginseng, which was manufactured for the past 6 years, showed a microbial level of 2.0${\times}$10\ulcorner to 7.2${\times}$10\ulcorner CFU/g of total aerobic bacteria and molds. The moisture content of commercial products was ranged from 13.54 to 17.26%, which were higher than that of the product standard, 14%. Irradiation of red ginseng at 2.5 kGy resulted in the reduction of microorganisms contaminated to below the detectable level. Irradiation prevented mold growth on red ginseng during storage at RH 90% and 25$^{\circ}C$; molds were found at the 72nd day after storage in 2.5 kGy-irradiated sample, while 41st day in the nonirradiated control. At this point of time, irradiated samples showed an increased level of moisture content required for mold growth, 22.2% in 2.5 kGy group and 21.5% in control group. Based on the above results, microbiological qualities of red ginseng could be effectively improved by the optimum dose of irradiation, which was expected to secure the quality stability of red ginseng during distribution under the high-moistured conditions.

  • PDF

A Study on the Detection of Abnormal Tissues in Biological Tissue Using Temperature Distribution According to Light Irradiation (광 조사에 따른 온도분포를 이용한 생체조직 내 비정상조직 탐지에 대한 연구)

  • Ko, Dong Guk;Im, Ihk-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.303-309
    • /
    • 2017
  • In this study, the characteristics of the temperature generated by light irradiation, on the surface of a biological tissue with an abnormal tissue part (paraffin) and at the surroundings of the abnormal tissue were studied by numerical and experimental methods. The temperature in the tissue was solved using the computational heat transfer and was compared with the temperature measured with thermocouples. The effects of the light wavelength and the irradiation time on the temperature distribution were analyzed. As a result, the temperature distribution from the irradiation of light in the biological tissue was different when there was an abnormal tissue part. The temperature in the biological tissue with the abnormal tissue part was higher than in a normal tissue.

Synchronized Expression of Two Bombyx mori Caspase Family Genes, ice-2 and ice-5 in Cells Induced by Ultraviolet Irradiation

  • Wang, Wenbing;Sun, Ying;Song, Lina;Wu, Yan;Wu, Huiling
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.17 no.1
    • /
    • pp.121-124
    • /
    • 2008
  • The caspase family proteins play an important role in programmed cell death (apoptosis). To date, the expression profiles of the caspase family genes in Bombyx mori (Bm) are poorly known. In this study, we examined the expression profiles of two novel Bm caspase family genes (ice-2 and ice-5), the potential change of the mitochondrial membrane and the morphology in Bm cells after stimulation of ultraviolet (UV) irradiation. The results showed the potential change of the mitochondrial membrane occurred at 5 hours after UV irradiation treatment. Analysis of fluorescent quantitative RT-PCR demonstrated that both the ice-2 and ice-5 might be involved in UV induced apoptosis in Bm cells. Notably, after UV irradiating, expression pattern of ice-2 and ice-5 were remarkably different. The ice-2 gene was highly expressed at two time points, 0.5 and 5 hours after UV stimulating, while the expression level of ice-5 only peaked at 5 hours after UV stimulating. It indicated that apoptosis induced by UV irradiation was involved in the mitochondrial pathway and the two isoforms of Bm ice may act but play different role during the apoptosis of Bm cells.

Study on irradiation effect by $Co^{60}$ to the carbon resistor (탄소저항체에 대한 $Co^{60}$조사효과에 관한 연구)

  • 지철근;조성욱
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.7-10
    • /
    • 1973
  • The characteristics of all the instruments and materials used in atomic industry is changed due to radiation damages by the effects of radiation activities. In this study, when the Carbon Resistor, main element of electrical circuits, is irradiated by Gamma-Ray, variations in its electrical properties have been investigated. The following results are obtained: 1) The resistance value in Carbon Resistor is exponentially increased as the quantity of irradiation by Gamma-Ray is increased, but in case of more than 10$^{6}$ R/hr. of quantity of irradiation it has saturated-state value. 2) The rate of change inrestistance value has been independent on the intensity of Gamma-Ray source when Carbon Resistor is irradiated in the same quantity of irradiation. 3) The resistance value in irradiated Carbon Resistor has not been varied with elapse of time. 4) The more the distance from the Carbon Resistor to the Gamma-Ray source the more greatly the resistance value is decreased and that it has been shown that the more quantity of irradiation by Gamma-Ray, the greater the rate of decrease in resistance value. Through the above results it has been concluded that the measurement values obtained by the high-precision instruments in the radiation field have to be corrected with proper consideration to radiation damages.

  • PDF

The Analysis of Spectrum on the Barkhausen Noise of Hysteresis Loops on Neutron Irradiated Material

  • Sim, Cheul-Muu;Chang, Kee-Ok;Park, Kook-Nam;Cho, Man-Soon;Park, Chang-Oong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1E
    • /
    • pp.7-12
    • /
    • 1999
  • In relation to a non-destructive evaluation of irradiation damages, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to a neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of RPV was irradiated to a neutron fluence of 2.3 ×10/sup 19/ n/㎠ (E ≥1 MeV) at 288℃. The saturation magnetization of neutron irradiated metal did not change. The neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by a neutron irradiation. The spectrum of Barkhausen noise is analysed with an applied frequency of 4 Hz and 8 Hz, sampling time of 50 μ sec and 20 μ sec. The harmonic frequency shows 4 Hz, 8 Hz, 12 Hz and 16 Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared on the irradiated specimen. In addition to the amplitude, the harmonic frequency of Barkhausen noise is taken into accounts as a promising tool for monitoring the irradiation induced degradation of the reactor materials such as a SA508 of PWR-RPV steel and a Zr₄ of HANARO-CNH.

  • PDF

Study on Changes of Sperm Count and Testis Tissue in Black Mouse after Neutron Irradiation (중성자 조사후 Black mouse의 고환 조직 및 정자수 변화에 관한 연구)

  • Chun, Ki-Jung;Seo, Won-Sook;Son, Hwa-Young
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.1
    • /
    • pp.31-35
    • /
    • 2006
  • For the purpose of the biological effect in black mouse by neutron irradiation, mice were irradiated with 16 or 32 Gy neutron (flux: 1.036739E+09) by tying flat pose at BNCT facility on HANARO Reactor. And 90 days later of irradiation, physical changes of testis and testis tissue were examined. There were no weight changes but a little bit volume changes and sperm counts in the testes. Atrophy of seminiferous tubules irradiated with 32 Gy neutron is increased in number and severity and those in stage VI showed depletion of spermatogonia and pachytene spermatocytes compared to the non-irradiated control group. Testis damage of black mouse was not recovered after long time by 32 Gy neutron irradiation.

Efficient Cleavage of Alkyl Aryl Ethers Using an Ionic Liquid under Microwave Irradiation

  • Park, Se Kyung;Battsengel, Oyunsaikhan;Chae, Junghyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.174-178
    • /
    • 2013
  • A highly reliable dealkylation protocol of alkyl aryl ethers, whose alkyl groups are longer than methyl group, has been developed. We report that various ethyl, n-propyl, and benzyl aryl ethers are successfully cleaved using an ionic liquid, 1-n-butyl-3-methylimidazolium bromide, [bmim][Br], under microwave irradiation. Despite many characteristics such as lower cost and less toxicity of the alkylating agents, and greater hydrophobicity of the products, longer alkyl ethers have been significantly less exploited than methyl ethers, probably due to more difficulty in the deprotection step. Since it has the same advantages as the demethylation method developed by this group including mild conditions, short reaction time, and small use of the ionic liquids, the dealkylation protocol can greatly encourage the broader use of longer alkyl groups in the protection of phenolic groups. As with our previous study of demethylation using [bmim][Br], the microwave irradiation is crucial for the deprotection of longer alkyl aryl ethers. Unlike the conventional heating, which causes either low conversion or decomposition, the microwave irradiation seems to more effectively provide energy to cleave the ether bonds and therefore suppresses the undesired reactions.

Effect of gamma irradiation on the critical heat flux of nano-coated surfaces

  • Rahimian, A.;Kazeminejad, H.;Khalafi, H.;Akhavan, A.;Mirvakili, M.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2353-2360
    • /
    • 2020
  • An anodic electrophoretic deposition (EPD) technique is used to create a uniform TiO2 thin film coating on boiling thin steel plates (1.1 mm by 90 mm). All of the effective parameters except time of the EPD method are kept constant. To investigate the effect of gamma irradiation on the critical heat flux (CHF), the test specimens were irradiated in a gamma cell to different doses ranging from 100 to 300 kGy, and then SEM and BET analysis were performed. For each coated specimen, the contact angle and capillary length were measured. The specimens were then tested in a boiling pool for CHF and boiling heat transfer coefficient. It was observed that irradiation significantly decreases the maximum pore diameter while it increases the porosity, pore surface area and pore volume. These surface modifications due to gamma irradiation increased the CHF of the nano-coated surfaces compared to that of the unirradiated surfaces. The heat transfer coefficient (HTC) of the nano-coated surfaces irradiated at 300 kGy increased from 83 to 160 kW/(㎡ K) at 885 kW/㎡ wall heat flux by 100%. The CHF of the irradiated (300 kGy) and unirradiated surfaces are 2035 kW/㎡ and 1583 kW/㎡, respectively, an increase of nearly 31%.

The Experimental Study on Biochemical Changes of Rat Liver Following Single Irradiation of High Energy X-ray (고(高)에너지 방사선(放射線)을 1회조사(一回照射)한 흰쥐 간(肝)의 생화학적(生化學的) 변화(變化))

  • Lee, Joon-Il;Park, Myeong-Hwan;Park, Chong-Sam
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.87-94
    • /
    • 1993
  • In order to investigate radiation effects on the liver, functional changes of liver were analyzed after irradiation. Doses of 10 Gy, 15 Gy and 20 Gy were exposed partially to the liver of male rats(Sprague-Dawley) with X-ray(4MV linear accelerator) at room temperature. On 1, 2, 4 and 8 weeks after irradiation, liver tissues and sera of the animals were compared with those of unirradiated animal by liver function tests. Enzyme activities in sera such as alanine aminotransferase, aspartate aminotransferase, malondialdehyde. The content of malondialdehyde in the activities of many enzymes including alanine aminotransferase, aspartate aminotransferase in sera were increased slightly with increasing exposure dose in all experiments and the activities of these enzymes increased markedly in 20 Gy irradiated groups. From these above results, functional changes of the liver were induced in all irradiated groups. Damaged liver was recovered along with time collapse after irradiation to the doses of 10 Gy and 15 Gy while no recovery was deteced within 8 weeks after irradiation to 20 Gy. These results suggest that careful attention must be paid to liver not to be included in exposure field in radiation therapy.

  • PDF

CHARACTERISTICS OF A NEW PNEUMATIC TRANSFER SYSTEM FOR A NEUTRON ACTIVATION ANALYSIS AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Baek, Sung-Yeol;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.813-820
    • /
    • 2009
  • A rapid pneumatic transfer system (PTS) for an instrumental neutron activation analysis (INAA) is developed as an automatic irradiation facility involving the measurement of a short half-life nuclide and a delayed neutron counting system. Three new PTS designs with improved functions were constructed at the HANARO research reactor in 2006. The new system is composed of a manual system and an automatic system for both an INAA and a delayed neutron activation analysis (DNAA). The design and basic conception of a modified PTS are described, and the functions of system operation and control, radiation protection and emissions of radioactive gas are improved. In addition, a form of capsule transportation of these systems is tested. The experimental results pertaining to the irradiation characteristics with variation of the neutron flux and the temperature of the irradiation position with the irradiation time are presented, as is an analysis of the reference material for analytical quality control and uncertainty assessments.