• Title/Summary/Keyword: Irradiation time

Search Result 1,443, Processing Time 0.032 seconds

DNA Synthesis and Radiosensitivity in Synchronized Human Kidney Cells in Vitro (동화시킨 사람의 신장세포에 있어서의 DNA 합성과 방사선감수성)

  • Kang, Yung-Sun;Park, Sang-Dai;Lee, Chung-Keel
    • The Korean Journal of Zoology
    • /
    • v.14 no.4
    • /
    • pp.175-180
    • /
    • 1971
  • The effects of X-irradiation on the mitotic activity, the chromosome aberration and the DNA synthetic pattern in synchronized human kidney cells treated with 5-AU were measured in the present experiment. When 5-AU was added, mitotic activity was markedly suppressed. After removal of the cells from the chemical, its activity proceeded synchronouly and reached peaks at hours 10. In 5-AU+100R groups, it was observed the X-ray caused mitotic delay, the irregularity of the time when mitotic peak appeared and the inhibiton of mitotic activity. In the control group, chromosome aerrations per cell was 0.030, whereas 0.147 in 5-AU treated group. In 5-AU+100R and 5-AU+200R groups, chromosome aberrations per cell were 0.583 and 0.669 respectively and the average chromosome aberrations per cell per R was 0.0035. 5-AU increased the frequency of labeled metaphases together with labeling intensity, and this is thought to be due to the accumulation of cells by 5-AU at S stage. On the contrary, X-ray decreased the labeling intensity and the frequency of labeled metaphases.

  • PDF

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Properties of liquid crystal alignment layers exposued to ion-beam irradiation enemies (이온빔 에너지에 따른 액정배향막의 전기광학적 특성연구)

  • Oh, Byeong-Yun;Lee, Kang-Min;Park, Hong-Gyu;Kim, Byoung-Yong;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.430-430
    • /
    • 2007
  • In general, polyimides (PIs) are used in liquid crystal displays (LCDs) as alignment layer of liquid crystals (LCs). Up to date, the rubbing alignment technique has been widely used to align liquid crystals on the PI surface, which is suitable for mass-production of LCDs because of its simple process and high productivity. However, this method has some disadvantages. Rubbed PI surfaces include the debris left by the cloth and the generation of electrostatic charges during rubbing process. Therefore, rubbing-free techniques for LC alignment are strongly required in LCD technology. In this experiment, PI was uniformly coated on indium-tin-oxide electrode substrates to form LC alignment layers using a spin-coating method and the PI layers were subsequently imidized at 433 K for 1 h. The thickness of the PI layer was set at 50 nm. The LC alignment layer surfaces were exposed to an $Ar^+$ ion-beam under various ion-beam energies. The antiparallel cells and twisted-nematic (TN) cells for the measurement of pretile angle and electro-optical characteristics were fabricated with the cell gap of 60 and $5\;{\mu}m$, respectively. The LC cells were filled with nematic LC (NLC, MJ001929, Merck) and were assembled. The NLC alignment capability on ion-beam-treated PI was observed using photomicroscope and the pretilt angle of the NLC was measured by the crystal-rotation method at room temperature. Voltage-transmittance (V-T) and response time characteristics of the ion-beam irradiated TN cell were measured by a LCD evaluation system.

  • PDF

Modeling of Dual Head Gantry Radiotherapy System with Monte Carlo Simulation (듀얼 헤드 갠트리 방사선치료 시스템 설계를 위한 몬테칼로 시뮬레이션 연구)

  • Park, Seungwoo
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.627-632
    • /
    • 2017
  • In order to design a dual-head gantry radiotherapy system, the single head of LINAC was modeled using GATE as a preliminary study. The LINAC head was designed with VARIAN manufacturer's information. 6 MV photons were generated from the head and the photons w irradiated to a water phantom for beam evaluation. GATE simulation was segmented by two stages, the one was to generate X-ray spectrum and the other one was for irradiation X-ray to the water phantom. The quantitative results were described in Percentage depth dose and beam profile. Two field size conditions were employed as $5{\times}5$ and $10{\times}10cm^2$. After beam quality was verified, dual heads gantry radiotherapy system were simulated and they was compared to the single head of LINAC system in terms of dose deposition with in the phantom. The simulated LINAC head showed acceptable beam quality result for radiotherapy. The efficiency was calculated that deposited dose from dual heads was divided by the dose from single head. At all conditions, dual heads showed higher treatment efficiency. Efficiency was increased about 40 to 60%. Form the result, The dual head gantry system of new LINAC system will contribute to the practical radiotherapy of tumor and to reduce treatment time.

Reliable and High Spatial Resolution Method to Identify the Number of MoS2 Layers Using a Scanning Electron Microscopy

  • Sharbidre, Rakesh Sadanand;Park, Se Min;Lee, Chang Jun;Park, Byong Chon;Hong, Seong-Gu;Bramhe, Sachin;Yun, Gyeong Yeol;Ryu, Jae-Kyung;Kim, Taik Nam
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.705-709
    • /
    • 2017
  • The electronic and optical characteristics of molybdenum disulphide ($MoS_2$) film significantly vary with its thickness, and thus a rapid and accurate estimation of the number of $MoS_2$ layers is critical in practical applications as well as in basic researches. Various existing methods are currently available for the thickness measurement, but each has drawbacks. Transmission electron microscopy allows actual counting of the $MoS_2$ layers, but is very complicated and requires destructive processing of the sample to the point where it will no longer be useable after characterization. Atomic force microscopy, particularly when operated in the tapping mode, is likewise time-consuming and suffers from certain anomalies caused by an improperly chosen set point, that is, free amplitude in air for the cantilever. Raman spectroscopy is a quick characterization method for identifying one to a few layers, but the laser irradiation causes structural degradation of the $MoS_2$. Optical microscopy works only when $MoS_2$ is on a silicon substrate covered with $SiO_2$ of 100~300 nm thickness. The last two optical methods are commonly limited in resolution to the micrometer range due to the diffraction limits of light. We report here a method of measuring the distribution of the number of $MoS_2$ layers using a low voltage field emission electron microscope with acceleration voltages no greater than 1 kV. We found a linear relationship between the FESEM contrast and the number of $MoS_2$ layers. This method can be used to characterize $MoS_2$ samples at nanometer-level spatial resolution, which is below the limits of other methods.

The Result of Combined Modality Treatment for Limited Stage Small Cell Lung Cancer (국소성 소세포 폐암에 대한 복합화학요법 및 방사선 병용치료의 효과)

  • Kim Jae Cheol;Jang Yang Suk;Ryu Samuel;Park In Kyu
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.205-211
    • /
    • 1989
  • From July 1984 to September 1988, 27 patients with limited stage small cell lung cancer were treated with combined modality (combination chemotherapy Plus radiotherapy) at the Department of Therapeutic Radiology in Kyungpook National University Hospital. Of the 27 patients, 19$(70\%)$ achieved a complete response, 6$(22\%)$ a partial response, and 2$(8\%)$ no response. Female, performance status HO, serum enolase level below 30ng/ml, radiation dose over 4500 cGy, and 4 or more cycles of chemotherapy had a favorable effect on the rates of complete response, although there were no statistical differences according to the variables. Median survival time was 10 months and overall 1- and 2-year survival rates were $40,7\%$ and $12.2\%$, respectively. Complete response (p<0.05), performance status HO (p<0.05), 4 or more cycles of chemotherapy (p<0.05), and radiation dose over 4500 cGy had a significantly favorable effect on 2-year survival rate. Prophylactic cranial irradiation or sex had no effect on survival. The results of this study suggest that radiation treatment should be combined with combination chemotherapy in the therapeutic strategy of SCLC of limited stage.

  • PDF

The Effect of Total Dose of Radiation on Normal Colon of Hybrid Mice (치료방사선 조사가 잡종 백색마우스의 대장에 미치는 병리조직학적 영향)

  • Jho, Gil-Ho;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.99-105
    • /
    • 1986
  • Optimal balance between control probability and risk of complication is emphasized even in present time, Although certain incidence of intestinal injury is accepted as an inevitable consequence after abdominopelvic irradiation, these complications still remain as problems. 60 mice were irradiated with 250 kVp orthovoltage x-ray machine and $200rad{\times}5/wk$ regimen. Histpathologic findings of colorectum and the relationship with occult blood test were analyzed and possible tolerable dose which would be safe from permanent complication was also estimated. Followings are the results: Mild mucosal and submucosal edema were observed in 1,000 rad irradiated group. Congestion of small vessels was prominent in 2,000 rad irradiated group and infiltration of inflammatory cells was observed in 3,000 rad irradiated group. Denuded mucosa was observed in 3,000 rad irradiated group. Occult blood test is not a proper indicator for rectal denuding or rectal ulcer, but our results suggest the possibility of using this as a relative scale of intestinal damage. Mitotic figures of crypt cells were observed even in 5,000 rad irradiated group, these suggest that the repair capacity of crypt cells are still functioning.

  • PDF

The Relationship Between Intestinal Iron Absorption and Hepatic Parenchymal Cell Damage (간실질세포(肝實質細胞)의 손상(損傷)이 철흡수(鐵吸收)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Mok-Hyun;Hahn, Shim-Suck
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.2
    • /
    • pp.19-40
    • /
    • 1971
  • Since the iron balance is maintained by regulated intestinal absorption rather than regulated excretion, there have been many reports concerning the factors which may influence the intestinal iron absorption. As the liver is the largest iron storage organ of the body, any hepatocellular damage may result in disturbances in iron metabolism, e,g., frequent co-existence of hemochromatosis and liver cirrhosis, or elevated serum iron level and increased iron absorption rate in patients with infectious hepatitis or cirrhosis. In one effort to demonstrate the influence of hepatocellular damage on intestinal iron absortion, the iron absorption rate was measured in the rabbits whose livers were injured by a single subcutaneous injection of carbon tetrachloride (doses ranging from 0.15 to 0.5cc per kg of body weight) or by a single irradiation of 2,000 to 16,000 rads with $^{60}Co$ on the liver locally. A single oral dose of $1{\mu}Ci\;of\;^{59}Fe$-citrate with 0.5mg of ferrous citrate was fed in the fasting state, 24 hours after hepatic damage had been induced, without any reducing or chelating agents, and stool was collected for one week thereafter. Serum iron levels, together with conventional liver function tests, were measured at 24, 48, 72, 120 and 168 hours after liver damage had been induced. All animals were sacrificed upon the completing of the one week's test period and tissue specimens were prepared for H-E and Gomori's iron stain. Following are the results. 1. Normal iron absorption rate of the rabbit was $41.72{\pm}3.61%$ when 0.5mg of iron was given in the fasting state, as measured by subtracting the amount recovered in stool collected for 7 days from the amount given. The test period of 7 days is adequate, for only 1% of the iron given was excreted thereafter. 2. The intestinal iron absorption rate and serum iron level were significantly increased when the animal was poisoned by a single subcutaneous injection of 0.15cc. per kg. of body weight of carbon tetrachloride or more, or the liver was irradiated with a single dose of 12,000 rads or more. The results of liver function tests which were done simultaneously remained within normal limit except SGOT and SGPT which were somewhat increased. 3. In each case, there has been good correlation between the extent of liver cell damage and degree of increased iron absorption rate or serum iron level. 4. The method of liver damage appeared to make no obvious difference in the pattern of iron deposit in liver. This may be partly due to the fact that tissue specimens were obtained too late, for by this time the elevated serum iron level had returned within normal range and the pathological changes were almost healed. 5. The possible factors and relationship between intestinal iron absorption and hepatic parenchymal cell damage has been discussed.

  • PDF

Intercomparison Study of the Neutron Personnel Dosemeters (중성자 개인선량계 상호비교)

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.49-57
    • /
    • 1998
  • Domestic intercomparison study of the neutron personnel dosemeters was performed for the first time in Korea. Thirteen types of neutron dosemeters from twelve institutions took part in this intercomparison study and the $D_2O$ moderated Cf-252 source of KAERI was used for irradiation. Eight of the fifteen dosemeters submitted by each participant were divided into two groups and each group was irradiated with different doses of the simulated mixed fields of neutron and gamma. The participants assessed their dosemeter reading in terms of the personal dose equivalent, Hp(10), for both neutron and gamma dose. The ratio of the reported dose equivalent to the delivered dose equivalent for comparison between participants ranged from 0.55 to 1.34 for neutron, from 0.54 to 1.32 for gamma and from 0.75 to 1.20 for total dose. This intercomparison results show that all dosemeter processors, especially for neutron category, are able to pass the personnel dosemeter performance test which shall be enforced according to the ordinance of the MOST, No. 96-6.

  • PDF

Selection of Salt Tolerant Rapeseed (Brassica napus L.) Mutant Lines Induced by Irradiation of Proton Ion Beams and Gamma Ray (양성자 및 감마선처리에 의한 유채 내염성 변이계통 선발)

  • Kim, Jun-Su;Eun, Jong-Seon;Han, Seung-Jin
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.211-220
    • /
    • 2011
  • This study was carried out to develop salt tolerant varities of rapeseed (Brassica napus L.) which can be grown in the high salty reclaimed land. The seeds of three varieties 'Naehan', 'Tammi', and 'Halla' were treated by proton ion beams and gamma rays with 0 to 2,000 Gy. For the selection of salt tolerant lines, emergence and survival rate, and growth characteristics of $M_2$ to $M_4$ generations were investigated in the Saemangeum reclaimed fields with the different salt concentrations. The lines with potential salt tolerance were selected in the $M_4$ generation and tested indoor for their growth characteristics. There was no significant changes in the soil pH for $M_4$ generation during growth period. However, soil EC was higher in early spring than sowing period (mid October). In $M_4$ generation test, the seeds of original and selected line showed high rates of emergence and survival, as determined one month after sowing. After wintering, however, the original varieties showed the significant reduction in the survival rate, while the selected lines showed a higher survival rate and good growth, leading to the completion of their life cycle. Consequently we selected 9 lines from $M_4$ generation with better performance in growth and yield. Soil EC was $2.8{\sim}4.3dS{\cdot}m^{-1}$ during $M_4$ generation growth period. The laboratory test of the lines selected from $M_4$ generation was made for their salt tolerance potential. The selected lines showed higher chlorophyll and proline contents than the original varieties. There was also no significant difference in the emergence rate of seed between the original and selected varieties. In 200 mM natural sea salt, the $N{\gamma}600-21-1-641$ line derived from 'Naehan' was the highest in growth rate, leaf chlorophyll and proline contents. $T{\gamma}800-20-2-461$ line derived from 'Tammi' didn't show significant difference in growth rate compared to original variety in 200 mM and withered in 250 mM like other lines as time passed. $H{\gamma}200-7-1-740$ line showed similar growth and chlorophyll content compared to its original variety.