• Title/Summary/Keyword: Irradiation test

Search Result 680, Processing Time 0.028 seconds

A Study on the Anesthetic Effects of Pulsed Nd:YAG Laser Irradiation to the Oral Mucosa and the Teeth (Nd:YAG 레이저 조사에 의한 치아 및 구강점막의 마취효과)

  • 최재갑
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • The aim of the study was to evaluate the anesthetic Effecs of pulsed Nd:YAG laser irradiation to the oral mucosa and the teeth. Twenty subjects who didn't have a history of significant systemic or current oral disease were included in this study. All the subjects were divided randomly into the experimental group and the control group with 10 for each group. Pain thresholds were measured with Weighted Needle Pinprick Sensory Threshold Test for the mucosal surface of lower lip and with electric pulp test for the upper right central incisor respectively, before and immediately after pulsed Nd:YAG laser irradiation in the condition of 2 watt, 20pps for 2 minute at 10mm distance. The experiment was double-blinded clinical trial. The results were as follows : 1. The mean pain threshold of the mucosal surface of lower lip for Weighted Needle Pinprick Sensory Threshold Test was 2.94(1.00g for the contral group respectively, and there was no statistical difference between two groups. 2. The mean pain threshold of the mucosal surface of lower lip was significantly increased immediately after pulsed Nd:YAG laser irradiation. 3. The mean pain threshold of the upper right central incisor for eledtric pulp test was 34.50(4.97V in the experimental group and 34.00(13.08V in the control group respectively, and there was no statistical difference between two groups. 4. The mean pain threshold of the upper right central incisor was significantly increased immediately after pulsed Nd:YAG laser irradiation.

  • PDF

IRRADIATION TEST OF MOX FUEL IN THE HALDEN REACTOR AND THE ANALYSIS OF MEASURED DATA WITH THE FUEL PERFORMANCE CODE COSMOS

  • WIESENACK WOLFGANG;LEE BYUNG-HO;SOHN DONG-SEONG
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.317-326
    • /
    • 2005
  • The burning-out of excess plutonium from the reprocessing of spent nuclear fuel and from the dismantlement of nuclear weapons is recently emphasized due to the difficulties in securing the final repository for the spent fuel and the necessity to consume the ex-weapons plutonium. An irradiation test in the Halden reactor was launched by the OECD Halden Reactor Project (HRP) to investigate the in-pile behavior of plutonium-embedded fuel as a form of mixed oxide (MOX) and of inert matrix fuel (IMF). The first cycle of irradiation was successfully accomplished with good integrity of test fuel rods and without any undesirable fault of instrumentations. The test results revealed that the MOX fuel is more stable under irradiation environments than IMF. In addition, MOX fuel shows lower thermal resistance due to its better thermal conductivity than IMF. The on-line measured in-pile performance data of attrition milled MOX fuel are used in the analysis of the in-pile performance of the fuel with the fuel performance code, COSMOS. The COSMOS code has been developed for the analysis of MOX fuel as well as $UO_2$ fuel up to high burnup and showed good capability to analyze the in-reactor behavior of MOX fuel even with different instrumentation.

A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test (조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구)

  • 김웅기;김수성;이철용;이도연;이정원
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

A Study on the Laser Welding of Cladding Tube with Temp. Sensor for Fuel Irradiation Test (핵연료 조사시험용 온도센서 피복재의 레이저용접 연구)

  • Kim, Su-Seong;Lee, Cheol-Yong;Kim, Ung-Gi;Lee, Jeong-Won;Go, Jin-Hyeon;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.106-108
    • /
    • 2005
  • The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15 mm. The soundness of welding area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various a pplications in the industry.

  • PDF

Effect of Ultrasound on the Properties of Biodegradable Polymer Blends of Poly(lactic acid) with Poly(butylene adipate-co-terephthalate)

  • Lee, Sang-Mook;Lee, Young-Joo;Lee, Jae-Wook
    • Macromolecular Research
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • This study investigated the effect of ultrasound irradiation on the blend of poly(lactic acid) (PLA) and poly(butylene adipate-co-terephthalate) (PBAT). The blends of PLA/PBAT(50/50) (PBAT50) were prepared in a melt mixer with an ultrasonic device attached. Thermal, rheological, and mechanical properties, morphology, and biodegradability of the sonicated blends were analysed. The viscosity of the sonicated blends was increased by the ultrasound irradiation owing to the strong interaction. The morphology of the sonicated blends was significantly dependent on the duration o the ultrasound irradiation. For PBAT50, the phase size reduction was maximized when the blends were ultrasonically irradiated for 30 sec. At longer duration of ultrasound irradiation, the PBAT phase underwent flocculation. Measurement of the tensile properties showed an increased breakage tensile stress and an enhanced Young's modulus when the blends were properly irradiated. This improvement was ascribed to better adhesion between the PLA matrix and the PBAT domain and to better dispersion of the PBAT phase. However, the tensile properties were maximized after excessive energy irradiation, which was ascribed to an emulsifying effect leading to coalescence of the PBAT phase. Impact strength was increased to reach a peak with the ultrasound irradiation, and was higher than the untreated sample for all sonicated samples due to the difference of failure mechanism between the tensile test and the impact test.

Design of Vessel Assembly for Fuel Irradiation Test in Reactor (원자로 내 핵연료조사시험용 압력용기조립체 설계)

  • Park, Kook-Nam;Lee, Jong-Min;Chi, Dae-Young;Park, Su-Ki;Lee, Chung-Young;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.383-387
    • /
    • 2004
  • The Fuel Test Loop (FTL) consists of In-Pile Test Section (IPS) and Out-of-Pile System (OPS). The test condition in IPS such as pressure, temperature and quality of the main cooling water, can be controlled by the OPS. The FTL has been developed to be able to irradiate three pins to the core irradiation hole (IR1 hole) by considering for its utility and user's irradiation requirement. The IPS vessel assembly (IVA) consists of IPS head, outer pressure vessel, inner pressure vessel, inner assembly and test fuel carrier. The IVA is approximately 5.6 m long and fits within a 74 mm in diameter envelope over the full height of the chimney. Above the top of the chimney, the head of the IPS is enlarged to allow the closure flanges and pipe work connections. IVA was designed to test the CANDU and PWR nuclear fuel pin together. Specially, wished to minimize interference by nuclear fuel change in design and synthesize these items and shape design for IVA.

  • PDF

IRRADIATION EFFECT ON SECRETING FUNCTION, AMYLASE ACTIVITY AND NUCLEIC ACID CONTENTS OF RAT PAROTID GLAND (방사선 조사가 이하선 기능에 미치는 영향에 관한 연구)

  • Cho Yong Jin;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.53-62
    • /
    • 1990
  • This experiment was performed to clarify the effects of /sup 60/Co gamma irradiation on secretory function, amylase activity and contents of nucleic acids of parotid gland in rat. Experimental animals were divided into 6th hours, 3rd, 7th, 14th and 28th days after irradiation and control. The experimental animals are singly irradiated with 20Gy (2,000rad) through protective lead block. Secretory function of parotid gland was evaluted by uptake and clearance of /sup 99m/TcO₄. /sup 99m/TcO₄. 0.2μ ci/gm, was injected into peritonium in uptake groups. Rats were sacrified with cervical dislocation after 30 minutes and gland was excised. In the clearance group. pilocarpine nitrate (8㎎/㎏) was intraperitoneally injected at 30 minutes after /sup 99m/TcO₄ injection and rats were sacrified 30 minutes after pilocarpine injection. Radioactivity of excised parotid gland was measured by using of gamma counter and stimulation-secretion coefficients, uptake radioactivity divided by clearance radioactivity, was calculated. Amylase activity and contents of DNA and RNA were determined by spectrophotometry. The results obtained were as follows: 1. In the uptake test, the radioactivity of /sup 99m/TcO₄ per unit weight increase in experimental group except 6th hours group, compared with control groups and showed a peak at 3rd days after irradiation. 2. In the clearance test, the radioactivity of /sup 99m/cO₄per unit weight rose to a peak at 3rd days after irradiation and gradually recovered thereafter. 3. Stimulation-secretion coefficient of parotid gland decreased at 6th hours, 3rd and 7th days after irradiation, and gradually increased. 4. Amylase activity of parotid gland decreased in 3rd and 7th days group, and especially lowest in 3rd days after irradiation. 5. The contents of DNA showed no definite difference in all the experimental groups, but RNA was seemed to decrease with time after irradiation.

  • PDF

One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors (cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定))

  • Bai, K.;Cho, S.H.;Lee, N.H.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

Electrical and Optical Properties in Transparent Conducting Oxides: Effect of Ultra Violet Irradiation

  • So, Byung-Soo;Hwang, Jin-Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.65-69
    • /
    • 2007
  • A design of experiments was applied in order to investigate the effect of processing variables in UV irradiation on the electrical/optical properties in indium-zinc oxide thin films, The processing variables, equivalently input variables are listed as UV irradiation time, oxygen flow rate, and chamber pressure. The statistical significance of Ultra Violet (UV) treatment was confirmed using a paired-t test. The full factorial $2^3$ design was employed to determine significant main and interaction effects in UV irradiation process. The chamber pressure and the interaction between UV irradiation time and $O_2$ flow rate were found to be statistically significant at the significance level of 0.1. Furthermore, the optimized approach was proposed in achieving the improved conductivity after UV irradiation.

  • PDF

A Study of Fatigue Strength Improvement for Cr-Mo Steel in Long Term service (장기간 사용한 Cr-Mo강의 피로강도향상 방법에 관한 연구)

  • 진영준
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.27-35
    • /
    • 2001
  • For the purpose of healing the degradation part, $CO_2$ laser beam was irradiated with different irradiation condition (porer, diameter, velocity and beam type) to find out optimum irradiation condition. The test series of hardness, residual stress measurement, and fatigue were carried out after the irradiation. Experimental results show that micro-hardness values on the surface of the irradiated specimens m approximately 2.5 times higher than those of un-irradiated ones. Fatigue tests show that the fatigue life was improved by the compressive residual stress after laser beam irradiation. However, some specimens with different conditions show the shorter fatigue life. It means that laser beam irradiation with optimum irradiation condition and optimum absorb energy, Q can improve the fatigue strength.

  • PDF