• 제목/요약/키워드: Irradiation test

검색결과 680건 처리시간 0.035초

현사시나무로 제조(製造)된 열압축목재(熱壓縮木材)와 목재(木材)-고분자(高分子) 복합체(複合體) 재질(材質)의 비교연구(比較硏究) (Comparative Study on Mechanical Properties and Dimensional Stability of Staypak and Wood-Polymer Composites from Populus alba × P. Glandulosa wood)

  • 박상범;안원영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권2호
    • /
    • pp.14-34
    • /
    • 1985
  • 본(本) 연구(硏究)에서는 국내산(國內産) 미이용(未利用) 활엽수재(闊葉樹材)인 현사시나무의 재질개량(材質改良)을 위한 방안(方案)으로 비닐계 단량체(單量體)인 methylmethacrylate (MMA) 용액(溶液)을 목재내(木材內)로 주입(注入)한 후(後) 가압(加壓) 가열(加熱) 촉매중합법(觸媒重合法)에 의하여 제조(製造)한 목재(木材)-고분자(高分子) 복합체(複合體)(WPC ; wood-polymer composites)와 열압축목재(熱壓縮木材) (Staypak ; heat-stabilized compressed wood)의 물리적(物理的), 기계적(機械的) 성질(性質)과 치수 안정성(安定性)을 조사(調査)하였다. WPC 제조시(製造時) 단량체(單量體)의 주입량(注入量)을 비교(比較)하기 위하여 침지법(浸漬法)과 진공감압법(眞空減壓法)을 실시(實施)하였다. 본(本) 연구(硏究)에서 얻어진 결과(結果)는 다음과 같다. 1. 목재내(木材內) 단량체(單量體)의 주입량(注入量)은 진공감압법(眞空減壓法)이 침지법(浸漬法)에 비(比)해 약(約) 2배(培)의 효과(效果)가 있었다. 2. 목재내(木材內)로 주입(注入)된 단량체(單量體)는 WPC 제조시(製造時) 약(約) 절반가량 중합(重合)되었다. 3. 제조(製造)된 WPC의 치수 안정효과(安定效果)의 측정결과(測定結果), 반경방향(半徑方向)에서의 항수축율(抗收縮率) 12.5~13.6%, 접선방향(接線方向)에서의 항수축율(抗收縮率)은 12.5~13.6%, 접선방향(接線方向)이 17.18~40.14%였다. 흡수감소율(吸收減少率)은 8.19~15.5%로 진공감압법(眞空減壓法)이 침지법(浸漬法)에 의(依)한 WPC보다 효과(效果)가 좋았다. 4. 휨강도(强度) 시험시(試險時) 하중(荷重)을 가(加)하는 방향(方向)을 달리하였을 때 반경방향(半徑方向)으로 하중(荷重)을 가(加)한 경우(境遇)가 접선방향(接線方向)에 비(比)해 높은 강도치(强度値)를 나타내었다. 5. Staypak 및 WPC는 소재(素材)에 비(比)해 횡압축강도(橫壓縮强度)가 70~90% 향상(向上)되었으며, 종압축강도(從壓縮强度)는 10~30% 증가(增加)되었다. 6. Staypak의 비중(比重)은 0.66, 침지법(浸漬法)에 의(依)한 WPC는 0.61, 진공감압법(眞空減壓法)에 의(依)한 WPC의 비중(比重)은 0.62, 소재(素材)는 0.44였다.

  • PDF

LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향 (EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT)

  • 정양석;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.623-631
    • /
    • 2007
  • 본 연구는 LED와 플라즈마 광원의 복합레진의 중합시 완속기시 중합방식(soft-start curing)이 수축응력에 미치는 효과를 비교, 평가하고자 하였다. 할로겐 광원으로 40초간 조사하여 복합레진을 중합한 경우와 LED와 플라즈마 광원의 단일광도 중합방식과 완속기시 중합방식으로 할로겐 40초 동안의 광에너지와 총량이 동일하도록 조사시간을 설정하였고 수축응력은 스트레인 게이지(Strain gauge)를 사용하여 측정하였다. 발생되는 수축응력을 비교, 분석 및 평가한 결과 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합 후 200초까지 수축응력이 급격하게 증가하였으나 이후 마지막 측정시간인 800초까지 완만한 증가를 보였다(P<0.05). 2. LED와 플라즈마 광원의 완속기시 중합방법이 단일광도 중합방법에 비해 수축응력이 낮게 나타났다(P<0.05). 3. 할로겐 광원과 LED와 플라즈마 광원의 완속기시 중합의 수축응력 비교에는 유의차가 없었다(P>0.05). 완속기시 중합 방식을 사용할 경우 단일광도 중합 방식보다 수축응력을 감소시킬 수 있어 임상적으로 고광도 광원인 LED와 플라즈마 광원의 경우 완속기시 중합 방식의 사용이 유리하다고 보여진다. 그러나 완속기시 중합시 불충분한 중합을 방지하기 위해서는 완속기시를 보완하는 추가적인 중합시간이 요구될 것으로 사료된다.

  • PDF

가금육의 이용과 가공기술 (Use of Chicken Meat and Processing Technologies)

  • 안동욱
    • 한국가금학회:학술대회논문집
    • /
    • 한국가금학회 2003년도 국제 심포지움
    • /
    • pp.67-88
    • /
    • 2003
  • 과거 20∼30 년 동안에 계육이나 칠면조육과 같은 가금육의 소비가 급성장하였는데 이렇게 되기까지는 매우 저렴한 가금육 가격, 많은 제품의 연구와 개발, 소비자들의 기호에 맞는 가금육의 특성, 소비자의 요구에 부응, 가금산업의 계열화와 통합, 가공에 관련된 장비들과 기술, 그리고 공격적인 마케팅 등과 같은 여러 요인들이 작용하였다. 그간에 연구 개발되어 활용된 가공기술로는 가금육의 성형/재구성, 텀블링, 염지, 훈연, 마사지, 염지액 주입, 향신료첨가, 유화, 빵가루도포, 액상도포, 종절, 절단 그리고 급속냉동과 같은 것들이 있다. 이처럼 발달된 가공기술들은 정육과 부분육 모든 부위에 사용되어졌다. 기계적으로 발골한 발골육 및 가슴과 다리 살코기를 이용한 다양한 제품의 개발로 인하여 가금육의 활용도가 더욱 증가하였다. 닭고기 가슴육은 건강식품의 상징이 되었고 고급식당과 요식업계에서 빠지지 않는 중요한 메뉴가 되었다. 그러나 다리, 날개, 북채와 같은 적육부분을 이용한 제품의 개발과 이용은 상대적으로 높은 지방함량 때문에 제한받아 왔다. 현재 대부분의 닭고기 제품은 구이용이나 인스턴트 제품 형태로 가공되어져서 판매되고 있다. 닭고기의 품질에서 중요한 문제는 비염지조리 가슴살에서 핑크색을 띠는 문제, 지방 산화, 이취, 가슴육에서의 PSE 발생 그리고 안전성과 같은 것들이 있다. 새로운 가공기술을 이용하여 신선육과 조리된 가금육의 품질과 안전성을 보증하기 위해서는 지금까지 행하여져 왔듯이 향후 끊임없는 연구개발이 중요하다고 할 수 있다. 특히, 신선육과 익힌 가금육의 방사선 조사의 응용이 향후 5 년 이내에 점차 증가하게 될 것으로 생각된다. 또한, 시장 점유율에서 인스턴트 식품용 육제품이 차지하는 비율이 점차 증가할 것이다. 또한 부분육을 이용한 완전제품, 적색육제품, 유기농이나 별미식 제품과 같은 형태의 다양한 포장육 제품이 도입 될 것으로 생각되어진다.e in vitro SPF test method will be able to be used as an alternative method for in vivo SPF in case of lotion and cream. replica. A statistically significant improvement of Star Fruit Leaf Extract BG30-treated site was seen in decreased wrinkles. Star Fruit Leaf Extract BG30 results in clinically visible improvement in wrinkling when used topically for 5 weeks. 또한 관계마케팅, CRM 등의 이론적 배경이 되고 있는 신뢰와 결속의 중요성이 재확인하는 결과도 의의라고 할 수 있다. 그리고 신뢰는 양사 간의 상호관계에서 조성될 수 있는 특성을 가진 반면, 결속은 계약관계 초기단계에서 성문화하고 규정화 할 수 있는 변수의 성격이 강하다고 할 수가 있다. 본 연구는 복잡한 기업간 관계를 지나치게 협력적 측면에서만 규명했기 때문에 많은 측면을 간과할 가능성이 있다. 또한 방법론적으로 일방향의 시각만을 고려했고, 횡단적 조사를 통하고 국내의 한 서비스제공업체와 관련이 있는 컨텐츠 공급파트너만의 시각을 검증했기 때문에 해석에서 유의할 필요가 있다. 또한 타당성확보 노력을 기하였지만 측정도구 면에서 엄격한 개발과정을 준수하지는 못했다. 향후에는 모바일 컨텐츠 파트너의 기업의 특성을 조사하여 관계성 변수와의 상호관련연구를 진행할 필요가 있다. 관계기간, 의존성, 거래처의 단/복수여부, 서비스 범주 등의 제반 변수를 고려하여 이러한 변수가 양사와의 관계성 변수에 어떤 영향이 있는가를 검증할 필요가 있다. 또한 신뢰, 결속 등 다차원의 개념에 대한 심도 깊은 연구와 최근 제기되고 있는 이론의 확대도 필요하다

  • PDF

방사선 치료를 시행 받은 폐암 환자에서 방사선 폐렴의 발생에 관한 예측 인자 (Factors Predicting the Development of Radiation Pneumonitis in the Patients Receiving Radiation Therapy for Lung Cancer)

  • 안진영;이연선;권선중;박희선;정성수;김진환;김주옥;조문준;김선영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제56권1호
    • /
    • pp.40-50
    • /
    • 2004
  • 연구배경 : 폐암은 우리 나라에서 점차 증가하고 있으며 발생빈도에 있어서는 위암에 이어서 두 번째이고 암에 의한 사망 원인의 첫 번째 원인이 되고 있다. 수술요법이 가장 좋은 치료이나 대부분의 환자들이 진단 당시 수술을 받지 못할 정도로 진행이 되어서 방사선 치료나 항암 치료를 동반한 방사선치료를 받게 된다. 방사선 치료 중 방사선 폐렴의 발생이 제일 중요한 부작용이다. 폐암으로 진단을 받고 흉부 방사선 치료를 시행 받은 환자에서 방사선 폐렴의 발생률 및 치료. 발생 및 중증도를 예측 할 수 있는 인자, 생존에 미치는 영향에 대해서 후향적 조사를 하였다. 방 법 : 충남대학교병원 호흡기 내과에서 폐암으로 진단을 받고 2000년 12월부터 2002년 12월까지 치료 방사선과에서 흉부 방사선 치료를 시행 받은 환자 90명을 대상으로 조사하였다. 결 과 : 90명의 환자 중 44명(48.9%)이 방사선 폐렴으로 진단을 받았으며 33명(36.6%)은 경증, 11명(12.3%)은 중증의 방사선 폐렴이 발생하였다. 중증의 방사선 폐렴 환자는 모두 부신 피질호르몬제를 사용하였으며 호흡 부전으로 내원한 한 환자를 제외한 나머지 10명의 환자들의 처음 평균 투여량은 prednisolone 34 mg(30~40)이었고, 평균 투여일수는 68일(8~97)이었다. 중증 방사선 폐렴이 발생된 경우에 있어서 경증에 비해 중앙 생존일이 의미 있게 낮았다.(p=0.046) 방사선 폐렴 발생과 관련된 인자는 방사선 투여량이 60 Gy 이상인 경우에 통계적으로 의미가 있었다.(p=0.001) 그 외에 활동도, 폐활량, 나이, 흡연, 조직형, 항암 치료와의 병용여부, 1일 방사선 조사 횟수, 방사선 투여 방식은 방사선 폐렴 발생과 통계적으로 의미가 없었다. 또한 중증의 방사선 폐렴 발생을 예측 할 수 있는 인자로 이용 될 수 있는 혈중 요산과 알부민의 농도와 방사선 폐렴의 중증도와는 통계적으로 의미가 없었다. 결 론 : 본 연구에서 60 Gy이상의 총 방사선 조사량이 방사선 폐렴의 발생과 관련이 있었고 조사량과 중증도와도 연관이 있음을 알 수 있었다. 또한 중증의 방사선 폐렴 발생 시 예후가 경증의 환자에 비해 상대적으로 좋지 못했다.

중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정 (Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel)

  • 오영택;강해진;김미화;전미선;강승희;서창옥;추성실;성진실;김귀언
    • Radiation Oncology Journal
    • /
    • 제20권3호
    • /
    • pp.264-273
    • /
    • 2002
  • 목적 : 최근 중합체 겔과 자기공명영상을 이용한 새로운 선량측정법이 알려졌으며, 이 방법은 기존의 선량측정법과는 달리 3차원적인 선량분포를 측정할 수 있다는 장점이 있다. 이 중합체 겔과 자기공명영상을 이용한 3차원적인 선량측정법의 유용성을 평가하고자 본 연구를 실행하였다. 대상 및 방법 : 산소를 제거하면서 겔 판톰을 만들고, 정해진 방사선량을 조사하였다. 자기공명영상촬영을 하여 조사된 방사선의 3차원 영상 및 횡이완시간(T2 relaxation time)을 구하고, 횡이완시간과 방사선량과의 함수관계를 구하였다. 구 모양의 겔 판톰을 제작하여 모의 방사선치료계획에 따라 방사선을 조사하고, 같은 방법으로 화소 당 횡이완시간을 구하고 그에 따른 3차원 선량분포도를 구한 다음 치료계획용 컴퓨터를 이용한 선량분포도와 비교하였다. 또한 같은 모의 방사선치료계획으로 Gaf-chromic 필름과 TLD를 이용하여 선량을 측정하고, 중합체 겔을 이용한 선량측정법과 기존 선량측정법과의 장단점을 비교 분석하였다. 결과 : 중합체 겔의 횡이완시간 및 그 역수와 방사선량은 2 Gy에서 15 Gy의 구간에서 선형의 함수관계를 이루고 있으며, 중합체 겔과 자기공명영상을 이용하여 3차원적인 선량분포를 구할 수 있었다. 매 측정 시마다 그 등선량곡선이 일정하여 측정 결과는 매우 안정적이었다. 이 중합체 겔 선량측정법은 치료계획 상의 선량분포와 거의 일치하였고, 절대선량과 깊이선량율에서 겔 선량측정법은 Gaf-chromic 필름 선량계 및 TLD 선량계와 치료계획상의 선량분포를 기준으로 할 때 그 정확도에서 비슷하거나 우월하였다. 결론 : 중합체 겔과 자기공명영상을 이용한 선량측정법은 아직 초기로 많은 개선점이 있으나 Gaf-chromic 선량측정법과 비슷하거나 우월한 정확성을 가지고 있을 뿐만 아니라 3차원적인 선량분포를 보여줄 수 있는 큰 장점을 가지고 있어, 3차원적인 선량분포를 이용하는 방사선치료에서 유용한 선량측정법으로 판단되며, 향후 임상적인 연구가 필요할 것으로 판단되었다.

한국형 총식이조사 및 UV/태양광 조사 버섯에서의 비타민 D 분석 (Vitamin D analysis in the Korean total diet study and UV/sun light irradiated mushrooms)

  • 서민정;노인화;이지연;권성옥;김초일;이계호
    • 한국식품저장유통학회지
    • /
    • 제30권1호
    • /
    • pp.109-121
    • /
    • 2023
  • 본 연구에서 식품 중 비타민 D 주요 급원으로 선정한 버섯류(3종), 어패류(10종), 알류(1종), 육류(7종), 두류(1종), 유류(4종), 가공식품(3종), 유지류(1종)로, 총 30종에 대표 조리법을 포함한 148건에 대해 LC-MS/MS를 이용하여 분석하였다. 우리 국민 평균 총식이섭취량의 90% 이상을 포괄하는 대상 식품을 선별 후 식생활에서 활용되는 조리법 선정을 통해 조제된 실제 섭취 상황에 가까운 한국형 총식이조사를 기반한 '대표 식품×대표 조리법'으로서 새송이버섯(굽기), 가다랭이(그대로) 등 53종으로 6개의 지역별 시료를 불검출의 경우 1건만 분석하였고, 검출된 경우 6건 전부 분석하여 총 148건에 대해 비타민 D 함량 및 섭취량을 추정하였다. 분석은 유효성검증 및 국제 분석 관리프로그램인 FAPAS를 참여하여 숙련도 테스트 결과, Z-score 2 이하의 만족하는 결과를 얻어 신뢰도를 검증하였다. 본 연구에서 분석한 '대표 식품×대표 조리법'의 비타민 D 결과는 어류에서는 멸치(볶기)에서 124.0 ㎍/kg의 농도로 가장 높게 검출되었고, 두 번째로 고등어(굽기)에서 120.2 ㎍/kg의 농도로 검출이 되었다. 달걀의 경우 달걀(끓이기)은 검출되지 않았고, 달걀(부치기)에서 최고 33.1 ㎍/kg의 농도로 검출이 되었다. 육류에서는 닭고기와 쇠고기는 전부 검출되지 않았고, 돼지고기의 경우 굽기에서 12.2 ㎍/kg으로 검출되었다. 유제품의 경우 요구르트(액상)에서 136.9 ㎍/kg, 가공식품 중 시리얼의 경우, 155.1 ㎍/kg의 농도로 비타민 D가 검출이 되었는데, 이는 비타민 D 강화 제품으로 보인다. 생표고버섯을 햇빛에 12시간 노출 시에 비타민 D 함량이 303.4 ㎍/kg으로 높았으며, 건조형태에 따라 갓이 위로 향할 때보다, 주름부분을 위로 향하였을 때 비타민 D2의 함량이 높음을 확인하였다. 비타민 D 함량 분석 결과를 토대로 섭취량을 추정한 결과, 우리 국민의 1인 1일 평균 비타민 D 섭취량은 0.99 ㎍/day이었으며, 비타민 D 섭취량에 기여한 중요 3가지 식품은 요구르트, 액상(31.3%), 달걀(28.1%), 시리얼(11.4%) 순이었다. 보건복지부와 한국영양학회에서 제공하는 한국인 영양소 섭취기준(2020년) 중 비타민 D의 1일 충분 섭취량(영양소의 필요량을 추정하기 위한 과학적 근거가 부족할 경우, 대상 인구집단의 건강을 유지하는 데 충분한 양을 설정한 수치)은 영유아 5 ㎍/day, 남녀 6세부터 75세 이상 5-15 ㎍/day로 본 연구에서 추정한 1인 1일 평균섭취량과 비교하였을 때, 우리 국민의 비타민 D 섭취가 부족하다는 것을 확인할 수 있었다. 비타민 D 부족을 개선하기 위해 생활양식이나 식습관을 통해 비타민 D를 증가시킬 수 있는 식품을 섭취하고, 부족한 부분은 보충제를 통한 비타민 D 섭취가 필요할 것으로 보인다. 버섯의 경우 햇빛 또는 자외선에 노출시키면 비타민 D 섭취량을 높일 수 있다. 식습관을 통해 비타민 D 부족을 개선할 수 있는 다양한 연구가 필요하다고 생각된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가 (Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response)

  • 김헌정;조영갑;김철수;김우철;이석호;노준규
    • Radiation Oncology Journal
    • /
    • 제17권2호
    • /
    • pp.113-119
    • /
    • 1999
  • 목적 :국소적으로 진행된 자궁경부암 환자에서 저용량의 Cisplatin을 방사선민감제로 사용하여 방사선치료와 동시 치료하였을 때의 급성독성 평가와 초기 반응을 평가하기 위하여 연구를 시행하였다. 대상 및 방법 : 본 연구는 1996년 12월부터 1999년 1월까지 FIGO Stage IIB-IIIB의 진행된 자궁경부암 환자 38명을 대상으로 하였다. 16명은 자궁경부암의 크기가 4cm이상인 환자들로 방사선 치료와 저용량의 cisplatin을 매일 동시에 치료 하였으며, 나머지 환자에선 방사선 치료 단독으로 치료하였다. 방사선치료는 골반강에 외부 방사선치료로 4500 cGy(3060cGy시행이후 midline block 추가), 자궁옅조직으로 침범이 있는 경우에는 자궁옅조직으로 방사선치료 부위를 줄여 900-1000cGy 추가치료를 시행하였고, 내부치료는 Ir$^{192}$고선량 근접 치료기(micro-Selectron HDR)로 6극회의 강 내조사(point "A"에 3000 to 3500cGy, 500cGy/fx, 2회/week)를 시행하였다. 방사선치료와 저용량의 cisplatin을 동시에 사용한 군에서는 방사선치료 첫날부터 방사선치료 20일째 되는 날까지 저용량의 cisplatin 10mg을 방사선치료 30분 전에 투여하였다. 급성독성의 평가는 expanded common toxicity criteria of the NCI Clinical Trial을 이용하였다. 초기반응의 평가는 방사선치료 종료이후 최소 4주이상의 추적조사가 가능한 사람들을 대상으로 시행되었다. 결과 : 급성독성 평가는 전체 38명에서 평가 가능하였으며, 방사선치료와 저용량의 cisplatin을 병용한 군에서 16명 중 6명(37.5$\%$)에서, 방사선 단독으로 치료한 군에서는 22명중 1명(6.2$\%$)에서 3등급 이상의 백혈구감소를 보였으며, 통계학적으로 의미있는 차이를 보였다 (P=0.030). 3등급 이상의 급성 위장간 독성은 저용량의 cisplatin을 병용한 군에서만 4명이 있었으나, 2-3일의 치료 중단이후 증상이 완화되어서 치료를 계속할 수 있었으며, 치료중 5kg이상의 체중감소는 방사선치료와 저용량의 cisplatin을 병용한 군에서는 16명중 3명(18.7$\%$), 방사선 단독으로 치료한 군에서는 22명중 2명(9.1$\%$)으로 통계학적으로 의미 있는 차이를 보이지 않았다(P=0.63). 초기반응은 추적조사가 4주 이상 가능하였던 34명을 대상으로 하였으며, 저용량의 cisplatin을 병용한 군에서 14명중 11명 (78$\%$), 방사선 단독으로 치료 군에서 20명중 16명(80$\%$)으로 통계학적으로는 의미있는 차이를 보이지 않았다(P=0.126). 결론 :국소 진행된 자궁경부암에 대한 방사선치료와 저용량의 cisplatin 병용요법 치료시 3등급 이상의 백혈구감소가 방사선치료 단독으로 치료시보다 많았으나, 1주 이하의 치료중단 이후 치료를 계속 할 수 있었으며, 4등급 이상의 백혈구감소와 치료에 의한 사망은 없었다. 초기반응에 대한 평가는 저용량의 cisplatin병용 군에서 4cm 이상의 자궁경부암을 가진 환자가 많음에도 불구하고 양 군에서 비슷한 정도의 반응을 보였으므로 진행된 자궁경부암의 치료에서 저용량의 cisplatin을 방사선민감제로 사용하여 치료결과의 향상을 기대할 수 있게 되었다. 따라서 저용량의 clsplatin과 방사선치료를 병용요법하였을 때의 치료효과를 판정하기 위해서는 phase III study가 필요하다.

  • PDF

횡경막상부에 국한된 임상적 병기 1-2기 호지킨병에서 치료 결과와 예후 인자의 분석 (The Analyses of Treatment Results and Prognostic Factors in Supradiaphragmatic CS I-II Hodgkin's Disease)

  • 박원;서창옥;정은지;조재호;정현철;김주항;노재경;한지숙;김귀언
    • Radiation Oncology Journal
    • /
    • 제16권2호
    • /
    • pp.147-157
    • /
    • 1998
  • 목적 : 시험개복술을 시행하지 않은 임상적 병기 1기, 2기 횡경막상부 호지킨병에서 후향적으로 치료 결과를 분석함으로써 시험개복술의 필요성을 재검토하였고 예후 인자를 분석하고, 예후 인자군의 유용성을 평가하고자 하였다. 대상 및 방법 : 1985년에서 1995년까지 연세의료원에서 횡경막 상부에 국한된 임상적 병기 1-2기 호지킨병으로 진단받고 치료를 받았던 51례를 대상으로 하였다. 연령은 4-67세까지 였으며 중앙값은 30세였고 병기별로는 IA, IIA, IIB가 각각 16례, 25례, 10례였다. 방사선치료는 4, 6MV 광자선으로 매일 1.5-1.8Gy씩 19.5Gy에서 55.6Gy(중앙값:45Gy)가 조사되었으며, 항암화학 요법은 방사선치료 전후에 2-12회(중앙값: 6회) 시행되었다. 방사선치료 단독, 항암화학방사선병용요법, 항암화학요법 단독이 각 각 31례, 16례, 4례에 시행되었고 방사선치료는 Involved field 방사선치료가 3례, 맨틀방사선치료가 26례, 부분적림프절방사선치료가 18례에서 시행되었다. 생존을 분석은 Kaplan-Meier method, 유의성 검증은 log-rank test를 이용하였다. 결과 : 5년 전체 생존율은 $87.6\%$, 무병 생존율은 $78.0\%$였다. 완전 관해된 50례 중 림프절만 재발한 경우가 4례, 간이나 폐 또는 비장에서 재발한 경우가 3례, 림프절과 간에 동시에 재발된 경우가 1례 있었다. 재발한 8례중 구제 치료가 항암화학요법 단독, 방사선치료 단독, 항암화학방사선병용요법이 각 각 4례, 1례, 2례에서 시행되어 이중 2례만 구제되었다. 여성이거나 거대 종격동 림프선비대가 있는 경우에 재발이 의미있게 많았고 전체 생존율은 B 증상이 있거나 임상적 .병기가 높을수록 의미있게 낮았다. EORTC 예후 인자군에 따른 5년 무병 생존율은 very favorable군 (VF관), favorable군(F군), unfavorable군(U군)이 각각 100, 100, $55.8\%$, 5년 전체 생존율은 100, 100, $75.1\%$로 통계적으로 의미있는 차이를 보여주었다. VF군과 F은 방사선치료만으로도 $100%$의 생존율을 보였으나 U군에서는 항암화학방사선병용요법시 방사선치료 단독보다 적은 재발율을 보였으나 생존율은 비슷하였다. 방사선치료를 받았던 경우에 맨틀방사선치료보다 부분적림프절방사선치료를 받은 경우에 무병 생존율이 높았다. 결론 : 횡경막상부에 국한된 호지킨병에서 시험개복술을 시행하지 않고도 좋은 치료 결과를 보여 주었다 성별, 거대 종격동 림프선비대가 무병 생존율에 의미있는 영향을 주었고 B 증상, 임상적 병기는 전체 생존율에 영향을 주는 중요한 예후 인자였다. 그리고 EORTC 예후 인자군에 따른 분류가 예후 예측과 치료 방법을 결정하는데 유용함을 확인할 수 있었다.

  • PDF