• 제목/요약/키워드: Irradiation test

검색결과 689건 처리시간 0.024초

Design of a New Capsule Controlling Neutron Flux and Fluence and Temperature of lest Specimen

  • Choo, Kee-Nam;Kang, Young-Hwan;Taiji Hoshiya;Motoji Niimi;Takashi Saito
    • Nuclear Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.148-157
    • /
    • 1997
  • A new capsule that has a unique structure in which the test environments including neutron flux and fluence, and irradiation temperature can be controlled precisely during irradiation, was conceptually designed. The capsule structure and instrumentation were successfully designed according to the JMTR's standard procedures of capsule design. Based on the target irradiation, the details of the irradiation such as neutron fluence and irradiation temperature ore calculated and the related capsule safety was evaluated. In addition, the effects of design parameters including the changes in inner-capsule configuration, heater capacity, and Helium gas pressure on the specimen temperature were analyzed with a computer program. Through these thermal and strength evaluations, this capsule was proved to be safe during the irradiation in the JMTR.

  • PDF

핵연료계장을 위한 정밀 드릴링장치 개발 (Development of Precision Drilling Machine for the Instrumentation of Nuclear Fuels)

  • 홍진태;정황영;안성호;정창용
    • 한국정밀공학회지
    • /
    • 제30권2호
    • /
    • pp.223-230
    • /
    • 2013
  • When a new nuclear fuel is developed, an irradiation test needs to be carried out in the research reactor to analyze the performance of the new nuclear fuel. In order to check the performance of a nuclear fuel during the irradiation test in the test loop of a research reactor, sensors need to be attached in and out of the fuel rod and connect them with instrumentation cables to the measuring device located outside of the reactor pool. In particular, to check the temporary temperature change at the center of a nuclear fuel during the irradiation test, a thermocouple should be instrumented at the center of the fuel rod. Therefore, a hole needs to be made at the center of fuel pellet to put in the thermocouple. However, because the hardness and the density of a sintered $UO_2$ pellet are very high, it is difficult to make a small fine hole on a sintered $UO_2$ pellet using a simple drilling machine even though we use a diamond drill bit made by electro deposition. In this study, an automated drilling machine using a CVD diamond drill has been developed to make a fine hole in a fuel pellet without changing tools or breakage of workpiece. A sintered alumina ($Al_2O_3$) block which has a higher hardness than a sintered $UO_2$ pellet is used as a test specimen. Then, it is verified that a precise hole can be drilled off without breakage of the drill bit in a short time.

원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험 (Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor)

  • 최명환;조만순;주기남;박승재;김봉구;강영환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

대각선 패턴에서 저항운동 시 발생한 방산의 효과가 신경의 흥분성에 미치는 영향 (The Effect of Irradiation During Resistance Exercise Using a Diagonal Pattern on the Excitability of Nerves)

  • 이민형;최수홍;하경진;이상열
    • PNF and Movement
    • /
    • 제19권1호
    • /
    • pp.97-104
    • /
    • 2021
  • Purpose: The human body can experience a variety of injuries. As a result, it may be difficult to directly treat the damaged area. In such a case, indirect treatment is required. Indirect treatment is typically PNF treatment. Morphological changes in muscle have been confirmed through several previous studies; however, few studies have analyzed neurological changes. Therefore, the purpose of this study was to determine how irradiation during resistance exercise using a diagonal pattern effects neurological excitability. Methods: Electromyography was performed on 13 healthy adults. A compound muscle action potential (CMAP) was obtained through a median motor nerve conduction velocity test, which was conducted before and after performing the irradiation exercise and general exercise. Results: Compared to baseline measurements, there was no significant difference in the latency of the irradiation exercise and general exercise. The amplitude of the CMAP measured after the irradiation exercise was significantly higher than after general exercise. Conclusion: Neurological excitability was high in irradiation during resistance exercise using a diagonal pattern. When clinically direct treatment is difficult, it is thought that irradiation can be used indirectly as a technique to induce nerve excitability.

X-Ray Diffraction line profile analysis of defects and precipitates in high displacement damage neutron-irradiated austenitic stainless steels

  • Shreevalli M.;Ran Vijay Kumar;Divakar R.;Ashish K.;Padmaprabu C.;Karthik V.;Archna Sagdeo
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.114-122
    • /
    • 2024
  • Irradiation-induced defects and the precipitates in the wrapper material of the Indian Fast Breeder Test Reactor (FBTR), SS 316 are analyzed using the synchrotron source-based Angle Dispersive X-Ray Diffraction (ADXRD) technique with X-rays of energy 17.185 keV (wavelength ~0.72146 Å). The differences and similarities in the high displacement damage samples as a function of dpa (displacement per atom) and dpa rate in the range of 2.9 × 10-7- 9 × 10-7 dpa/s are studied. Ferrite and M23C6 are commonly observed in the present set of high displacement damage 40-74 dpa SS 316 samples irradiated at temperatures in the range of 400-483 ℃. Also, the dislocation density has increased as a function of the irradiation dose. The X-ray diffraction peak profile parameters quantified such as peak shift and asymmetry show that the irradiation-induced defects are sensitive to the dpa rate-irradiation temperature combinations. The increase in yield strength as a function of displacement damage is also correlated to the dislocation density.

방사선 조사 마우스에서 학습기억 장애에 대한 홍삼의 효과 (Effect of Red Ginseng on Radiation-induced Learning and Memory Impairment in Mouse)

  • 이해준;김중선;문창종;김종춘;조성기;장종식;김성호
    • Journal of Ginseng Research
    • /
    • 제33권2호
    • /
    • pp.132-138
    • /
    • 2009
  • Previous studies suggest that even low-dose irradiation can lead to progressive cognitive decline and memory deficits, which implicates, in part, hippocampal dysfunction in both humans and experimental animals. In this study, whether red ginseng (RG) could attenuate memory impairment was investigated through a passive-avoidance and object recognition memory test, as well as the suppression of hippocampal neurogenesis, using the TUNEL assay and immunohistochemical detection with markers of neurogenesis (Ki-67 and doublecortin (DCX)) in adult mice treated with a relatively low-dose exposure to gamma radiation (0.5 or 2.0 Gy). RG was administered intraperitonially at a dosage of 50 mg/kg of body weight, at 36 and 12 h pre-irradiation and at 30 minutes post-irradiation, or orally at a dosage of 250 mg! kg of body weight/day for seven days before autopsy. In the passive-avoidance and object recognition memory test, the mice that were trained for one day after acute irradiation (2 Gy) showed significant memory deficits compared with the sham controls. The number of TUNEL-positive apoptotic nuclei in the dentate gyrus (DG) was increased 12 h after irradiation. In addition, the number of Ki-67- and DCX-positive cells was significantly decreased. RG treatment prior to irradiation attenuated the memory defect and blocked apoptotic death as well as a decrease in the Ki-67- and DCX-positive cells. RG may attenuate memory defect in a relatively low-dose exposure to radiation in adult mice, possibly by inhibiting the detrimental effect of irradiation on hippocampal neurogenesis.

STATUS OF FACILITIES AND EXPERIENCE FOR IRRADIATION OF LWR AND V/HTR FUEL IN THE HFR PETTEN

  • Bakker Klaas;Klaassen Frodo;Schram Ronald;Futterer Michael
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.417-422
    • /
    • 2006
  • The present paper describes the 45 MW High Flux Reactor (HFR) which is located in Petten, The Netherlands. This paper focuses on selected technical aspects of this reactor and on nuclear fuel irradiation experiments. These fuel experiments are mainly experiments on Light Water Reactor (LWR) and Very/High Temperature Reactor (V/HTR) fuels, but also on Fast Reactor (FR) fuels, transmutation fuels and Material Test Reactor (MTR) fuels.

UV-A 조사에 의한 Phenothiazines의 돌연변이원성 비교 연구 (Comparative Study on the Mutagenic Activity of Phenothiazines by UV-A Irradiations)

  • 김봉희;박영아
    • 한국식품위생안전성학회지
    • /
    • 제9권1호
    • /
    • pp.15-21
    • /
    • 1994
  • The mutagenic activity of four phenothiazine derivatives such as chlorpromazine, perphenazine, trifluoperazine and thioridazine in conjunction with UV-A irradiation or not based on the Ames plate incorporation test in the presence and absence of liver microsomal enzyme(S9 fraction). None of these compounds and their photo-excited were detected as mutagen in the Salmonella microsome assay with TA 98 and TA 100.

  • PDF

방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구 (Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients)

  • 박영환
    • 대한방사선협회지
    • /
    • 제27권2호
    • /
    • pp.181-197
    • /
    • 2001
  • Thus, among peripheral blood, the number of WBC decreased drastically for a certain period after total body irradiation with high dose radiation, and the levels of Seg. neutriphil and lymphocyte decreased significantly after irradiation in the lymphocyte

  • PDF

장기간 사용한 Cr-Mo강의 내식성 향상 방법에 관한 연구 (A Study of Corrosion Resistance Improvement for Cr-Mo Steel in Long Term Service)

  • 진영준
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.8-15
    • /
    • 2006
  • It is no wonder that mechanical structures are accompanied by problems related to corrosion after being exposed to long hours of work. Corrosion of mechanical structures has been the most serious problem in the field of industry. The present study employed a laser beam irradiation test to improve the corrosion resistance of degraded Cr-Mo steel, which was used for more than 60,000 hours. To find the optimum irradiation test condition for the corrosion resistance of degraded Cr-Mo steel, hardness and residual stress measurements, micro-structural observation, and the electrochemical potentiokinetic reactivation (EPR) tests were performed with changes in laser beam test conditions including laser beam output, diameter, and velocity. Thus, the present study indicates that the optimum test condition and absorption energy for a laser beam test need to be determined to enhance corrosion resistance of degraded Cr-Mo steel.