• Title/Summary/Keyword: Irradiated volume

Search Result 168, Processing Time 0.034 seconds

Comparison of irradiated and non-irradiated acellular dermal matrices in breast reconstruction under radiotherapy

  • Woo, Soo Jin;Ha, Jeong Hyun;Jin, Ung Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.33-43
    • /
    • 2021
  • Background Acellular dermal matrices (ADMs) have become an essential material for implant-based breast reconstruction. No previous studies have evaluated the effects of sterility of ADM under conditions of radiation. This study compared sterile (irradiated) and aseptic (non-irradiated) ADMs to determine which would better endure radiotherapy. Methods Eighteen male Balb/C mice were assigned to the control group with no irradiation (group 1) or one of two other groups with a radiation intensity of 10 Gy (group 2) or 20 Gy (group 3). Both sterile and aseptic ADMs were inserted into the back of each mouse. The residual volume of the ADM (measured using three-dimensional photography), cell incorporation, α-smooth muscle actin expression, and connective tissue growth factor expression were evaluated. The thickness and CD3 expression of the skin were measured 4 and 8 weeks after radiation. Results In groups 2 and 3, irradiated ADMs had a significantly larger residual volume than the non-irradiated ADMs after 8 weeks (P<0.05). No significant differences were found in cell incorporation and the amount of fibrosis between irradiated and non-irradiated ADMs. The skin was significantly thicker in the non-irradiated ADMs than in the irradiated ADMs in group 3 (P<0.05). CD3 staining showed significantly fewer inflammatory cells in the skin of irradiated ADMs than in non-irradiated ADMs in all three groups after 4 and 8 weeks (P<0.05). Conclusions Under radiation exposure, irradiated ADMs were more durable, with less volume decrease and less deposition of collagen fibers and inflammatory reactions in the skin than in non-irradiated ADMs.

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Effect of Nd:YAG laser irradiation on adherence of retrograde filling materials: evaluation by micro-computed tomography

  • Kim, Minyoung;Kim, Hyeon-cheol;Kwak, Sang Won;Yoon, Tai Cheol;Kim, Euiseong
    • The Journal of the Korean dental association
    • /
    • v.54 no.11
    • /
    • pp.865-873
    • /
    • 2016
  • Background/Purpose: The purpose of this study was to evaluate the effect of Nd:YAG irradiation on adherence of retrograde filling materials (mineral trioxide aggregate [MTA] and Super-EBA) by micro-computed tomography (CT) measurement and to observe the dentinal surface after irradiation by scanning electron microscopy (SEM). Materials and methods: Forty retrofilling models using extracted human teeth were divided into four groups according to the material and method used: ProRoot MTA (MTA group), Super-EBA (EBA group), MTA with Nd:YAG laser irradiation (LMTA group), and Super-EBA with Nd:YAG laser irradiation (LEBA group). All specimens were stored in 100% humidity for 24 hours until micro-CT was performed. The gap volume of the tooth/material interface was measured using the CTAn program. In six samples, the laser-irradiated dentin surface was observed using SEM. Results: The mean percent difference in gap volume was not statistically significant between the Nd:YAG laser-irradiated groups and non-irradiated in both materials(P > 0.05). The gap volume in the MTA group was significantly lower than that in the EBA group (P < 0.05). Examination of the non-irradiated specimens by SEM showed patent dentinal tubules. In contrast, alterations in the texture of the dentin surface and obliteration of the dentinal tubules were evident in the Nd:YAG laser-irradiated specimens. Conclusion: In this study, changes in the dentinal surface after Nd:YAG irradiation did not affect adherence between the apical filling material and the dentin wall.

  • PDF

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

Effect of Aloe vera on the Blood Components of Cobalt-60 Gamma Irradiated Rats (Aloe vera가 Cobalt-60 gamma선 조사를 받은 쥐의 혈액성분에 미치는 영향)

  • Choi Min-chul
    • Journal of the korean veterinary medical association
    • /
    • v.26 no.1
    • /
    • pp.38-42
    • /
    • 1990
  • The effect of Aloe vera administration(500mg/kg, P.O.) for 21 days on the total white blood cell, packed cell volume, hemoglobin, total protein, serum glutamic pyruvic transaminase and sorbitol dehydrogenase values in cobalt-60 gamma irradiated rats was s

  • PDF

Effects of neutron irradiation on densities and elastic properties of aggregate-forming minerals in concrete

  • Weiping Zhang;Hui Liu;Yong Zhou;Kaixing Liao;Ying Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2147-2157
    • /
    • 2023
  • The aggregate-forming minerals in concrete undergo volume swelling and microstructure change under neutron irradiation, leading to degradation of physical and mechanical properties of the aggregates and concrete. A comprehensive investigation of volume change and elastic property variation of major aggregate-forming minerals is still lacking, so molecular dynamics simulations have been employed in this paper to improve the understanding of the degradation mechanisms. The results demonstrated that the densities of the selected aggregate-forming minerals of similar atomic structure and chemical composition vary in a similar trend with deposited energy due to the similar amorphization mechanism. The elastic tensors of all silicate minerals are almost isotropic after saturated irradiation, while those of irradiated carbonate minerals remain anisotropic. Moreover, the elastic modulus ratio versus density ratio of irradiated minerals is roughly following the density-modulus scaling relationship. These findings could further provide basis for predicting the volume and elastic properties of irradiated concrete aggregates in nuclear facilities.

The Effect of Obesity Levels on Irradiated Small Bowel volume in Belly Board with Small Bowel Displacement Device for Rectal Cancer Radiotherapy (복부판과 소장변위도구를 사용하는 직장암의 방사선치료 시 비만도가 소장의 조사용적에 미치는 영향)

  • Kim, Se-Young;Kim, Joo-Ho;Park, Hyo-Kuk;Cho, Jeong-Hee
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.39-47
    • /
    • 2013
  • For radiotherapy in rectal cancer patients treated with small bowel displacement device (SBDD) and belly board, We will suggest new indication of using SBDD depending on obesity index by analyzing correlation between obesity and irradiated small bowel volume. In this study, We reviewed 29 rectal cancer patients who received pelvic radiation therapy with belly board and SBDD from January to April in 2012. We only analyzed those patients treated with three-field technique (PA and both LAT) on 45 Gy (1.8 Gy/fx). We measured patients' height, weight, body mass index (BMI), waist-hip ratio (WHR) and divided BMI into two groups.(${\geq}23$:BMI=group1, <23:BMI=group2) We performed a statistical analysis to evaluate correlation between total volume of bladder($TV_{bladder}$), obesity index and high dose volume of small bowel (small bowel volume irradiated at 90% of prescribed dose, $HDV_{sb}$), low dose volume of small bowel (small bowel volume irradiated at 33% of prescribed dose, $LDV_{sb}$). The result shows, gender, WHR and status of pre operative or post operative do not greatly affect $HDV_{sb}$ and $LDV_{sb}$. Statistical result shows, there are significant correlation between $HDV_{sb}$ and BMI (p<0.04), $HDV_{sb}$ and $TV_{bladder}$ (p<0.01), $LDV_{sb}$ and $TV_{bladder}$ (p<0.01). BMI seems to correlate with $HDV_{sb}$ but does not with $LDV_{sb}$ (p>0.05). There are negative correlation between $HDV_{sb}$ and BMI, $TV_{bladder}$ and $HDV_{sb}$, $TV_{bladder}$ and $LDV_{sb}$. Especially, BMI group1 has more effective and negative correlation with $HDV_{sb}$ (p=0.027) than in BMI group2. In the case of BMI group 1, $TV_{bladder}$ has significant negative correlation with $HDV_{sb}$ and $LDV_{sb}$ (p<0.04). In conclusions, we confirmed that Using SBDD with belly board in BMI group1 could more effectively reduce irradiated small bowel volume in radiation therapy for rectal cancer. Therefore, We suggest using belly board with SBDD in order to reduce the small bowel toxicity in rectal radiotherapy, if patients' BMI is above 23.

Volume Resistivity Characteristics of Low Density Polyethylene film irradiated with Electron Beam (전자선 조사된 저밀도 폴리에틸렌 박막의 체적고유저항 특성)

  • Cho, Don-Chan;Cho, Kyung-Soon;Lee, Soo-Won;Kim, Wang-Kon;Hong, Jin-Wooog
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.193-195
    • /
    • 1996
  • Low-density polyethylene(LDPE ; thickness 100[${\mu}m$] as a experimental specimen is irradiated with electron beam by using electron beam accelerator, and as an experimental specimen, the nonirradiated specimen and the specimen irradiated with electron beam is produced according to the classification of dose. From the analysis of DSC, the crystalline melting point of the specimen irradiated with electron beam is lower than that of virgin specimen. It is confirmed thai the volume resistivity is increased from the temperature over $50[^{\circ}C]{\sim}60[^{\circ}C]$ to the crystalline melting point because of the defects of solid structure and the formation of many trap centers by means of electron beam irradiation, but decreased in the temperature over the crystalline melting point because of the melt of crystalline.

  • PDF

Multiscale simulations for estimating mechanical properties of ion irradiated 308 based on microstructural features

  • Dong-Hyeon Kwak ;Jae Min Sim;Yoon-Suk Chang ;Byeong Seo Kong ;Changheui Jang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2823-2834
    • /
    • 2023
  • Austenitic stainless steel welds (ASSWs) of nuclear components undergo aging-related degradations caused by high temperature and neutron radiation. Since irradiation leads to the change of material characteristics, relevant quantification is important for long-term operation, but limitations exist. Although ion irradiation is utilized to emulate neutron irradiation, its penetration depth is too shallow to measure bulk properties. In this study, a systematic approach was suggested to estimate mechanical properties of ion irradiated 308 ASSW. First of all, weld specimens were irradiated by 2 MeV proton to 1 and 10 dpa. Microstructure evolutions due to irradiation in δ-ferrite and austenite phases were characterized and micropillar compression tests were performed. In succession, dislocation density based stress-strain (S-S) relationships and quantification models of irradiation defects were adopted to define phases in finite element analyses. Resultant microscopic S-S curves were compared to verify material parameters. Finally, macroscopic behaviors were calculated by multiscale simulations using real microstructure based representative volume element (RVE). Validity of the approach was verified for the unirradiated specimens such that the estimated S-S curves and 0.2% offset yield strengths (YSs) which was 363.14 MPa were in 10% agreement with test. For irradiated specimens, the estimated YS were 917.41 MPa in 9% agreement.

The Aging Effects on Electrical Properties for the Irradiated EPDM (방사선을 조사한 EPDM에서 전기적 특성의 경년열화 효과)

  • 류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.78-87
    • /
    • 2000
  • The $\gamma$-ray irradiation and aging effects on electrical characteristics of $^{60}Co$ $\gamma$-ray irradiated ethylene-propylene-diene-terpolymer(EPDM) contained with 1 to 3phr phenolic and quinolinic antioxidants as antirads were investigated. The marked effects of type and amounts of the antioxidant on the volume resistivity and AC breakdown strength of the $\gamma$-ray irradiated EPDM are different. A phenolic antioxidant(IR 1010) contribute to improving the electrical insulation properties on the EPDM better than quinolinic antioxidant(Kumanox RD) during irradiation. In aging the irradiated EPDM specimens contained antioxidants at room temperature in air, it was shown a improvement of insulation properties due to radical scavenging and crosslinking of EPDM aged until 360 days.

  • PDF