• Title/Summary/Keyword: Iris method

Search Result 286, Processing Time 0.024 seconds

A Study on Iris Image Restoration Based on Focus Value of Iris Image (홍채 영상 초점 값에 기반한 홍채 영상 복원 연구)

  • Kang Byung-Jun;Park Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.2 s.308
    • /
    • pp.30-39
    • /
    • 2006
  • Iris recognition is that identifies a user based on the unique iris texture patterns which has the functionalities of dilating or contracting pupil region. Iris recognition systems extract the iris pattern in iris image captured by iris recognition camera. Therefore performance of iris recognition is affected by the quality of iris image which includes iris pattern. If iris image is blurred, iris pattern is transformed. It causes FRR(False Rejection Error) to be increased. Optical defocusing is the main factor to make blurred iris images. In conventional iris recognition camera, they use two kinds of focusing methods such as lilted and auto-focusing method. In case of fixed focusing method, the users should repeatedly align their eyes in DOF(Depth of Field), while the iris recognition system acquires good focused is image. Therefore it can give much inconvenience to the users. In case of auto-focusing method, the iris recognition camera moves focus lens with auto-focusing algorithm for capturing the best focused image. However, that needs additional H/W equipment such as distance measuring sensor between users and camera lens, and motor to move focus lens. Therefore the size and cost of iris recognition camera are increased and this kind of camera cannot be used for small sized mobile device. To overcome those problems, we propose method to increase DOF by iris image restoration algorithm based on focus value of iris image. When we tested our proposed algorithm with BM-ET100 made by Panasonic, we could increase operation range from 48-53cm to 46-56cm.

Iris recognition robust to noises

  • Kim, Jaemin;Jungwoo Won;Seongwon Cho
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.42-45
    • /
    • 2003
  • This paper describes a new iris recognition method using shift-invariant subbands. First an iris image is preprocessed to compensate the variation of the iris image. Then, the preprocessed iris image is decomposed into multiple subbands using a shift invariant wavelet transform. The best subband among them, which have rich information for various iris pattern and robust to noises, is selected for iris recognition. The quantized pixels of the best subband yield the feature representation. Experimentally, we show that the proposed method produced superb performance in iris recognition.

  • PDF

Iris Localization using the Pupil Center Point based on Deep Learning in RGB Images (RGB 영상에서 딥러닝 기반 동공 중심점을 이용한 홍채 검출)

  • Lee, Tae-Gyun;Yoo, Jang-Hee
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.135-142
    • /
    • 2020
  • In this paper, we describe the iris localization method in RGB images. Most of the iris localization methods are developed for infrared images, thus an iris localization method in RGB images is required for various applications. The proposed method consists of four stages: i) detection of the candidate irises using circular Hough transform (CHT) from an input image, ii) detection of a pupil center based on deep learning, iii) determine the iris using the pupil center, and iv) correction of the iris region. The candidate irises are detected in the order of the number of intersections of the center point candidates after generating the Hough space, and the iris in the candidates is determined based on the detected pupil center. Also, the error due to distortion of the iris shape is corrected by finding a new boundary point based on the detected iris center. In experiments, the proposed method has an improved accuracy about 27.4% compared to the CHT method.

A Novel Eyelashes Removal Method for Improving Iris Data Preservation Rate (홍채영역에서의 홍채정보 보존율 향상을 위한 새로운 속눈썹 제거 방법)

  • Kim, Seong-Hoon;Han, Gi-Tae
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.10
    • /
    • pp.429-440
    • /
    • 2014
  • The iris recognition is a biometrics technology to extract and code an unique iris feature from human eye image. Also, it includes the technology to compare with other's various iris stored in the system. On the other hand, eyelashes in iris image are a external factor to affect to recognition rate of iris. If eyelashes are not removed exactly from iris area, there are two false recognitions that recognize eyelashes to iris features or iris features to eyelashes. Eventually, these false recognitions bring out a lot of loss in iris informations. In this paper, in order to solve that problems, we removed eyelashes by gabor filter that using for analysis of frequency feature and improve preservation rate of iris informations. By novel method to extract various features on iris area using angle, frequency, and gaussian parameter on gabor filter that is one of the filters for analysing frequency feature for an image, we could remove accurately eyelashes with various lengths and shapes. As the result, proposed method represents that improve about 4% than previous methods using GMM or histogram analysis in iris preservation rate.

A Iris Recognition Using Zernike Moment and Wavelet (Zernike 모멘트와 Wavelet을 이용한 홍채인식)

  • Choi, Chang-Soo;Park, Jong-Cheon;Jun, Byoung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4568-4575
    • /
    • 2010
  • Iris recognition is a biometric technology that uses iris pattern information, which has features of stability, security etc. Because of this reason, it is especially appropriate under certain circumstances of requiring a high security. Recently, using the iris information has a variety uses in the fields of access control and information security. In extracting the iris feature, it is desirable to extract the feature which is invariant to size, lights, rotation. We have easy solutions to the problem of iris size and lights by previous processing but there is still problem of iris feature extract invariant to rotation. In this paper, To improve an awareness ratio and decline in speed for a revision of rotation, it is proposed that the iris recognition method using Zernike Moment and Daubechies Wavelet. At first step, the proposed method groups rotated iris into similar things by statistical feature of Zernike Moment invariant to a rotation, which shortens processing time of iris recognition and looks equal to an established method in the performance of recognition too. therefore, proposed method could confirm the possibility of effective application for large scale iris recognition system.

A New Circle Detection Algorithm for Pupil and Iris Segmentation from the Occluded RGB images

  • Hong Kyung-Ho
    • International Journal of Contents
    • /
    • v.2 no.3
    • /
    • pp.22-26
    • /
    • 2006
  • In this paper we introduce a new circle detection algorithm for occluded on/off pupil and iris boundary extraction. The proposed algorithm employs 7-step processing to detect a center and radius of occluded on/off eye images using the property of the chords. The algorithm deals with two types of occluded pupil and iris boundary information; one is composed of circle-shaped, incomplete objects, which is called occluded on iris images and the other type consists of arc objects in which circular information has partially disappeared, called occluded off iris images. This method shows that the center and radius of iris boundary can be detected from as little as one-third of the occluded on/off iris information image. It is also shown that the proposed algorithm computed the center and radius of the incomplete iris boundary information which has partially occluded and disappeared. Experimental results on RGB images and IR images show that the proposed method has encouraging performance of boundary detection for pupil and iris segmentation. The experimental results show satisfactorily the detection of circle from incomplete circle shape information which is occluded as well as the detection of pupil/iris boundary circle of the occluded on/off image.

  • PDF

Implementation of Embedded System for a Fast Iris Identification Based on USN (고속의 홍채인식을 위한 USN기반의 임베디드 시스템 구현)

  • Kim, Shin-Hong;Kim, Shik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.4
    • /
    • pp.190-194
    • /
    • 2009
  • Iris recognition is a biometric technology which can identify a person using the iris pattern. Recently, using iris information is used in many fields such as access control and information security. But Perform complex operations to extract features of the iris. Because high-end hardware for real-time iris recognition is required. This paper is appropriate for the embedded environment using local gradient histogram embedded system with iris feature extraction methods based on USN(Ubiquitous Sensor Network). Experimental results show that the performance of proposed method is comparable to existing methods using Gabor transform noticeably improves recognition performance and it is noted that the processing time of the local gradient histogram transform is much faster than that of the existing method and rotation was also a strong attribute.

  • PDF

Iris Recognition Using Ridgelets

  • Birgale, Lenina;Kokare, Manesh
    • Journal of Information Processing Systems
    • /
    • v.8 no.3
    • /
    • pp.445-458
    • /
    • 2012
  • Image feature extraction is one of the basic works for biometric analysis. This paper presents the novel concept of application of ridgelets for iris recognition systems. Ridgelet transforms are the combination of Radon transforms and Wavelet transforms. They are suitable for extracting the abundantly present textural data that is in an iris. The technique proposed here uses the ridgelets to form an iris signature and to represent the iris. This paper contributes towards creating an improved iris recognition system. There is a reduction in the feature vector size, which is 1X4 in size. The False Acceptance Rate (FAR) and False Rejection Rate (FRR) were also reduced and the accuracy increased. The proposed method also avoids the iris normalization process that is traditionally used in iris recognition systems. Experimental results indicate that the proposed method achieves an accuracy of 99.82%, 0.1309% FAR, and 0.0434% FRR.

Iris Lacuna Extraction using Watershed (Watershed를 이용한 홍채 열공 추출)

  • 박현선;한일호;김회율
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.53-56
    • /
    • 2002
  • In this paper, we propose the method of iris lacuna extraction using watershed transform. Lacuna is salient feature of iris. It has three dimensional structure formed by leak of pigmentation and loss of fiber tissues. Lacuna can be used for iris recognition system, and generally used in health diagnosis and character analysis with its shape and position. The main idea of the proposed method is applying the watershed transform to radial gray scale profile of iris image. The result shows that the lacuna can be extracted automatically from eye image.

  • PDF

A Study on the Restoration of a Low-Resoltuion Iris Image into a High-Resolution One Based on Multiple Multi-Layered Perceptrons (다중 다층 퍼셉트론을 이용한 저해상도 홍채 영상의 고해상도 복원 연구)

  • Shin, Kwang-Yong;Kang, Byung-Jun;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.438-456
    • /
    • 2010
  • Iris recognition uses a unique iris pattern of user to identify person. In order to enhance the performance of iris recognition, it is reported that the diameter of iris region should be greater than 200 pixels in the captured iris image. So, the previous iris system used zoom lens camera, which can increase the size and cost of system. To overcome these problems, we propose a new method of enhancing the accuracy of iris recognition on low-resolution iris images which are captured without a zoom lens. This research is novel in the following two ways compared to previous works. First, this research is the first one to analyze the performance degradation of iris recognition according to the decrease of the image resolution by excluding other factors such as image blurring and the occlusion of eyelid and eyelash. Second, in order to restore a high-resolution iris image from single low-resolution one, we propose a new method based on multiple multi-layered perceptrons (MLPs) which are trained according to the edge direction of iris patterns. From that, the accuracy of iris recognition with the restored images was much enhanced. Experimental results showed that when the iris images down-sampled by 6% compared to the original image were restored into the high resolution ones by using the proposed method, the EER of iris recognition was reduced as much as 0.133% (1.485% - 1.352%) in comparison with that by using bi-linear interpolation