• Title/Summary/Keyword: Iris 법

Search Result 45, Processing Time 0.025 seconds

The effect of cavity wall property on the shear bond strength test using iris method (Iris 법을 이용한 전단접착강도 측정에서 와동벽의 영향)

  • Kim, Dong-Hwan;Bae, Ji-Hyun;Cho, Byeong-Hoon;Lee, In-Bog;Baek, Seung-Ho;Ryu, Hyun-Mi;Son, Ho-Hyun;Um, Chung-Moon;Kwon, Hyuck-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.170-176
    • /
    • 2004
  • Objectives : In the unique metal iris method. the developing interfacial gap at the cavity floor resulting from the cavity wall property during polymerizing composite resin might affect the nominal shear bond strength values. The aim of this study is to evaluate that the iris method reduces the cohesive failure in the substrates and the cavity wall property effects on the shear bond strength tests using iris method. Materials and Methods : The occlusal dentin of 64 extracted human molars were randomly divided into 4 groups to simulate two different levels of cavity wall property (metal and dentin iris) and two different materials ($ONE-STEP^{\circledR}$ and $ALL-BOND^{\circledR}$ 2) for each wall property. After positioning the iris on the dentin surface. composite resin was packed and light-cured. After 24 hours the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Fracture analysis was performed using a microscope and SEM. The data was analyzed statistically by a two-way ANOV A and t-test. Results : The shear bond strength with metal iris was significant higher than those with dentin iris (p=0.034). Using $ONE-STEP^{\circledR}$, the shear bond strength with metal iris was significant higher than those with dentin iris (p=0.005), but not in $ALL-BOND^{\circledR}$ 2 (p=0.774). The incidence of cohesive failure was very lower than other shear bond strength tests that did not use iris method. Conclusions:The iris method may significantly reduce the cohesive failures in the substrates. According to the bonding agent systems. the shear bond strength was affected by the cavity wall property.

A Study on the Restoration of a Low-Resoltuion Iris Image into a High-Resolution One Based on Multiple Multi-Layered Perceptrons (다중 다층 퍼셉트론을 이용한 저해상도 홍채 영상의 고해상도 복원 연구)

  • Shin, Kwang-Yong;Kang, Byung-Jun;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.438-456
    • /
    • 2010
  • Iris recognition uses a unique iris pattern of user to identify person. In order to enhance the performance of iris recognition, it is reported that the diameter of iris region should be greater than 200 pixels in the captured iris image. So, the previous iris system used zoom lens camera, which can increase the size and cost of system. To overcome these problems, we propose a new method of enhancing the accuracy of iris recognition on low-resolution iris images which are captured without a zoom lens. This research is novel in the following two ways compared to previous works. First, this research is the first one to analyze the performance degradation of iris recognition according to the decrease of the image resolution by excluding other factors such as image blurring and the occlusion of eyelid and eyelash. Second, in order to restore a high-resolution iris image from single low-resolution one, we propose a new method based on multiple multi-layered perceptrons (MLPs) which are trained according to the edge direction of iris patterns. From that, the accuracy of iris recognition with the restored images was much enhanced. Experimental results showed that when the iris images down-sampled by 6% compared to the original image were restored into the high resolution ones by using the proposed method, the EER of iris recognition was reduced as much as 0.133% (1.485% - 1.352%) in comparison with that by using bi-linear interpolation

Analysis of waveguide iris using FEM-BIM its application to waveguide filter design (유한 요소 경계 적분법을 이용한 구형 도파관 내 임의의 형상 iris 해석 및 도파관 여파기 설계에의 응용)

  • 박종근;남상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1244-1250
    • /
    • 1997
  • An arbitrary shaped iris in rectangular waveguideis investigated using FEM-CDMA with triangularprism elements in this paper. The volume of irisis subdivided into a relatively small number of triangular prism elements and FEM is used to formulate the field distribution. On the other hand, the fields in the waveguide region are represented by BIM derived from the waveguide Green's function and boundary conditions. The proposed method is verified through the design and experiment for the circular iris filter using WR-90 waveguide.

  • PDF

A 20 GHz low-loss dual - mode channel filter using mode matching method (모드정합법을 이용한 20GHz 저손실 이중모드 채널여파기)

  • 정근욱;이재현;유경완;강성춘
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.53-59
    • /
    • 1997
  • In this paper, we present a 20 GHz low-loss dual-mode channel filter designed by using mode matching method. The performance of dual-mode channel filter mainly depends on iris characteristics. Therefore the exact design of iris is the key point to get good frequncy response of the filter. MOde matching technique is widely used ot design several kinds of waveguide filters because it is simple in theory and can easily calculate the scattering matrices at the discontinuities with simple structure like iris coupled filters. Additionally the effect for finite thickness of the iris in the dual-mode cavity iflter is analyzed by te full-wave method, providing the exact filter implementation without trial and error.

  • PDF

A Study on the Efficient IFEM for Analyzing an Arbitrary-shaped Iris in Rectangular Waveguide (구형 도파관내 임의 형상 Iris 해석을 위한 효율적인 반복 유한 요소법에 관한 연구)

  • 박종국;김병성;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1175-1181
    • /
    • 2001
  • An efficient hybrid method is proposed to analyze discontinuities in a rectangular waveguide. Only with a small number of meshes around a discontinuity, the typical finite element method is shown to give an exact solution through several iterative updates of the boundary conditions. To show the validity of the proposed method, a simple circular aperture in a rectangular waveguide is analyzed and its result is compared with FEBIM.

  • PDF

An Iris-coupled Partial H-plane Filter (아이리스 결합형 Partial H-plane 필터)

  • Kim Dong-Won;Lee Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.128-133
    • /
    • 2005
  • An iris-coupled partial H-plane filter as a new type of partial H-plane filter is proposed. The proposed filter can be compared with conventional H-plane filter and uses an iris-type evanescent waveguide as a coupling structure. Filter design technique based on numerical simulation is developed to design and compare the proposed filter and H-plane filter. Designed iris-coupled partial H-plane filter has the same frequency response as that of the conventional H-plane filter while its cross section is one quarter. A good agreement between measurements and theoretical prediction is achieved.

A Study of an Collarette Extraction in Iris Image (홍채 영상에서 자율신경환 추출에 관한 연구)

  • 강진영;김장형
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.754-757
    • /
    • 2003
  • In Oriental medicine, the shape of collarette that formed with position in iris of patients often used by health diagnotcian to grasp health condition. In this paper, we present method that effectively extract collarette that exist in Iris image. After proposed method detert iris area using circular edge detector, derides boundary candidate point through radial line search and threshold value establishment. And boundary candidate line is treated to use nearest neighbor calculation at each boundary candidate point, finally extracts collarette through linear interpolation. As a result of experimenting about iris images, We Confirmed that can be used as assistant tool of diagnostic system that can presume state of ventriculus of human body.

  • PDF

Exploration of Economic Valuation Model for the UX Design using the Contingent Valuation Method - Focusing on the Screen Unlock Interfaces (조건부 가치측정법을 이용한 사용자 경험 디자인 가치평가 모델의 탐색 잠금해제 인터페이스를 중심으로)

  • Lee, Jinsung;Cho, Kwang-Su;Choi, Junho
    • Journal of the HCI Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • This study aimed to assess the economic value of the UX design and applied contingent valuation method (CVM) to the three smartphone screen unlock interface types: touch, fingerprint, and iris recognition. The contingent valuation method was chosen from various economic valuation approaches because the interface components such as the screen unlock are important user experience values but non-market goods which are not traded independently. Using the double-bounded dichotomous choice approach of the contingent valuation method, the survey results of the logit model showed that the economic value of touch unlock interface was 529 won, fingerprint was 4,214 won, and iris recognition was 1,316 won. That is, the fingerprint interface had the highest economic value, followed by iris recognition and touch interface. The main contribution of this research is that we examined a method for economic valuation of the UX design and generated systematic and credible results.

Design and Fabrication of Rectangular Iris Waveguide Filter for Microwave Broadcasting Transponder (마이크로파 방송 중계기용 구형창 도파관 필터 설계 및 제작)

  • 문성익;양두영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.4
    • /
    • pp.530-538
    • /
    • 1999
  • In this paper, design of rectangular iris waveguide filter for the microwave broadcasting transponder using WR137 is applied to the modified ${TE^x}_{mn}$ mode theory in order to exactly analyze the characteristic of the waveguide discontinuity. We designed and fabricated the rectangular iris waveguide filter with the bandwidth 47 MHz for the microwave broadcasting transponder applied the conjugate gradient method to the modified ${TE^x}_{mn}$ mode theory. The results show a good characteristics that the $S_{11}$ and $S_{21}$ are -23 ㏈, -0.56 ㏈ and the maximum VSWR is below 1.02 in the passband.

  • PDF

A Fast Iris Region Finding Algorithm for Iris Recognition (홍채 인식을 위한 고속 홍채 영역 추출 방법)

  • 송선아;김백섭;송성호
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.876-884
    • /
    • 2003
  • It is essential to identify both the pupil and iris boundaries for iris recognition. The circular edge detector proposed by Daugman is the most common and powerful method for the iris region extraction. The method is accurate but requires lots of computational time since it is based on the exhaustive search. Some heuristic methods have been proposed to reduce the computational time, but they are not as accurate as that of Daugman. In this paper, we propose a pupil and iris boundary finding algorithm which is faster than and as accurate as that of Daugman. The proposed algorithm searches the boundaries using the Daugman's circular edge detector, but reduces the search region using the problem domain knowledge. In order to find the pupil boundary, the search region is restricted in the maximum and minimum bounding circles in which the pupil resides. The bounding circles are obtained from the binarized pupil image. Two iris boundary points are obtained from the horizontal line passing through the center of the pupil region obtained above. These initial boundary points, together with the pupil point comprise two bounding circles. The iris boundary is searched in this bounding circles. Experiments show that the proposed algorithm is faster than that of Daugman and more accurate than the conventional heuristic methods.