• Title/Summary/Keyword: Ir-192 isotope

Search Result 6, Processing Time 0.021 seconds

The Activity Check of Brachytherapy Isotope (근접치료동위원소의 Activity Check)

  • Kim, Gun-Oh;Lee, Byung-Koo;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ${\pm}2.1\%$. (which belongs to recommendable value for AAPM ${\pm}5\%$ as difference of error range) It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  • PDF

Ir-192 Brachytherapy Planning of Brain Tumor (Ir-192 방사성소선원에 의한 뇌종양의 치료계획)

  • Choi Tae Jin;Park Jeong Ho;Kim Ok Bae;Suh Soo Ji
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.277-281
    • /
    • 1988
  • Although widely used in external beam treatment planning, computed tomography scans are infrequent in incranial tumors by implanting of Radioactive isotope. This incranial brachytherapy has only become possible by using CT scans and stereotaxic operation methods. The coincidence of single source and tumor axes in brachytherapy is very important to determine the therapeutic dosages. Eventhough using the CT scan, according to spatial location of tumor tying, the section of tumor will be seen enlargement, cause the tumor will be cut off with slight angle to its axes. Correct analysis of tumor size from source is required for rotated axes in analytical geometry.

  • PDF

Performance Evaluation of a Fiber-Optic Cerenkov Radiation Sensor System Using a Simulated Spent Fuel Assembly (사용후핵연료 집합체 모사장치를 이용한 광섬유 체렌코프 방사선 센서 시스템의 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Park, Byung Gi;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.245-250
    • /
    • 2014
  • When the charged particle travels in transparent medium with a velocity greater than that of light in the same medium, the electromagnetic field close to the particle polarizes the medium along its path, and then the electrons in the atoms follow the waveform of the pulse which is called as Cerenkov light or radiation. This type of radiation can be easily observed in a spent fuel storage pit. In optical fibers, the Cerenkov light also can be generated due to their dielectric components. Accordingly, the radiation-induced light signals can be obtained using optical fibers without any scintillating material. In this study, to measure the intensities of Cerenkov radiation induced by gamma-rays, we have fabricated the fiber-optic Cerenkov radiation sensor system using silica optical fibers, plastic optical fibers, multi-anode photomultiplier tubes, simulated spent fuel assembly and a scanning system. To characterize the Cerenkov radiation generated in optical fibers, the intensities of Cerenkov radiation generated in the silica and plastic optical fibers were measured. Also, we measured the longitudinal distribution of gamma rays emitted from the Ir-192 isotope by using the fiber-optic Cerenkov radiation sensor system and simulated spent fuel assembly.

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.

  • PDF