• Title/Summary/Keyword: Ion trap

검색결과 121건 처리시간 0.022초

Optimum Radius Size between Cylindrical Ion Trap and Quadrupole Ion Trap

  • Chaharborj, Sarkhosh Seddighi;Kiai, Seyyed Mahmod Sadat;Arifin, Norihan Md;Gheisari, Yousof
    • Mass Spectrometry Letters
    • /
    • 제6권3호
    • /
    • pp.59-64
    • /
    • 2015
  • Quadrupole ion trap mass analyzer with a simplified geometry, namely, the cylindrical ion trap (CIT), has been shown to be well-suited using in miniature mass spectrometry and even in mass spectrometer arrays. Computation of stability regions is of particular importance in designing and assembling an ion trap. However, solving CIT equations are rather more difficult and complex than QIT equations, so, analytical and matrix methods have been widely used to calculate the stability regions. In this article we present the results of numerical simulations of the physical properties and the fractional mass resolutions m/Δm of the confined ions in the first stability region was analyzed by the fifth order Runge-Kutta method (RKM5) at the optimum radius size for both ion traps. Because of similarity the both results, having determining the optimum radius, we can make much easier to design CIT. Also, the simulated results has been performed a high precision in the resolution of trapped ions at the optimum radius size.

Ion Trap Mass Spectrometer와 Quadrupole Mass Spectrometer를 이용한 유기인제 및 유기염소제 농약 분석에 관한 연구 (Study on the Residue Analysis of Organophosphorus and Organochlorine Pesticides with Ion Trap and Quadrupole Mass Spectrometer)

  • 이재성;박현미;어연우
    • 대한화학회지
    • /
    • 제39권12호
    • /
    • pp.902-909
    • /
    • 1995
  • Ion trap 질량분석기와 Quadrupole 질량분석기를 이용한 밀가루 중 유기인제(dimethoate, diazi-non, parathion-methyl, fenithion, malathion) 및 인삼 중 BHC 이성질체들의 정성 정량 분석에 대한 유용성을 평가하기 위해 검출한계를 구하고, 검량선을 작성하였다. 이온화 방법으로 EI와 CI를 사용하여 mass fragmentation pattern을 비교하여 정성분석에 적용하였으며, scan과 selected ion monitoring(SIM) mode로 미량분석법으로서의 유용성을 평가하였다. 검출한계는 ion trap에서 scan시 0.008-0.225ng이었으며, quadru-pole에서는 scan시 0.23-3.1ng, SIM 측정시 0.032-0.68ng으로ion trap이 quadrupole의 scan시 보다 2-300배, SIM보다 4-30배까지 검출한계가 낮았다. 검량선의 직선성은 ion trap과 quadrupole모두 0.9이상이었다. 밀가루 추출물은 Bio-Bead S-X3를 사용하여 정제하였고, 인삼은 Florisil column으로 정제하였다. 5종의 유기인제의 회수율은 80% 이상이었으며, BHCs의 회수율은 60-90%이었다.

  • PDF

Single Nanoparticle Ion Trap (SNIT): A Novel Tool for Studying in-situ Dynamics of Single Nanoparticles

  • Seo, Sung-Cheol;Hong, Seung-Kyun;Boo, Doo-Wan
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권5호
    • /
    • pp.552-554
    • /
    • 2003
  • The development of high performance single nanoparticle ion trap (SNIT) apparatus for studying in-situ dynamics of single nanoparticles in controlled environments is described. The performance of SNIT apparatus has been evaluated for 500 nm SiO₂particles. The mass resolution of ~100 ppm and the capability of varying the charge states independently have been demonstrated.

Applications of Stochastic Process in the Quadrupole Ion traps

  • Chaharborj, Sarkhosh Seddighi;Kiai, Seyyed Mahmod Sadat;Arifina, Norihan Md;Gheisari, Yousof
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.91-98
    • /
    • 2015
  • The Brownian motion or Wiener process, as the physical model of the stochastic procedure, is observed as an indexed collection random variables. Stochastic procedure are quite influential on the confinement potential fluctuation in the quadrupole ion trap (QIT). Such effect is investigated for a high fractional mass resolution Δm/m spectrometry. A stochastic procedure like the Wiener or Brownian processes are potentially used in quadrupole ion traps (QIT). Issue examined are the stability diagrams for noise coefficient, η=0.07;0.14;0.28 as well as ion trajectories in real time for noise coefficient, η=0.14. The simulated results have been obtained with a high precision for the resolution of trapped ions. Furthermore, in the lower mass range, the impulse voltage including the stochastic potential can be considered quite suitable for the quadrupole ion trap with a higher mass resolution.

Nanomanipulation and Nanomanufacturing based on Ion Trapping and Scanning Probe Microscopy (SPM)

  • Kim, Dong-Whan;Tae, Won-Si;Yeong, Maeng-Hui;K. L. Ekinci
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.530-537
    • /
    • 2004
  • Development of a versatile nanomanipulation tool is an overarching theme in nanotechnology. Such a tool will likely revolutionize the field given that it will enable fabrication and operation of a wealth of interesting nanodevices. This study seeks funding to create a novel nanomanipulation system with the ultimate goal of using this system for nanomanufacturing at the molecular level. The proposed design differs from existing approaches. It is based on a nanoscale ion trap integrated to a scanning prove microscope (SPM) tip. In this design, molecules to be assembled will be ionized and collected in the nanoscale ion trap all in an ultra high vacuum (UHV) environment. Once filled with the molecular ions, the nanoscale ion trap-SPM tip will be moved on a substrate surface using scanning probe microscopy techniques. The molecular ions will be placed at their precise locations on the surface. By virtue of the SPM, the devices that are being nanomanufactured will be imaged in real time as the molecular assembly process is carried out. In the later stages, automation of arrays of these nanomanipulators will be developed.

  • PDF

Investigation of Ne and He Buffer Gases Cooled Ar+ Ion Clouds in a Paul Ion Trap

  • Kiai, S.M. Sadat;Elahi, M.;Adlparvar, S.;Nemati, N.;Shafaei, S.R.;Karimi, Leila
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.112-115
    • /
    • 2015
  • In this article, we examine the influences of Ne and He buffer gases under confined Ar+ ion cloud in a homemade Paul ion trap in various pressures and confinement times. The trap is of small size (r0 = 1 cm) operating in a radio frequency (rf) voltage only mode, and has limited accuracy of 13 V. The electron impact and ionization process take place inside the trap and a Faraday cup has been used for the detection. Although the experimental results show that the Ar+ ion FWHM with Ne buffer gas is wider than the He buffer gas at the same pressure (1×10-1 mbar) and confinement time is about 1000 μs, nevertheless, a faster cooling was found with He buffer gas with 500 μs. ultimetly, the obtanied results performed an average cloud tempertures reduced from 1777 K to 448.3 K for Ne (1000 μs) and from 1787.9 K to 469.4 K for He (500 μs)

Study of CO2+(CO2)n Cluster in a Paul Ion Trap

  • Karimi, L.;Sadat Kiai, S.M.;babazaheh, A.R.;Elahi, M.;Shafaei, S.R.
    • Mass Spectrometry Letters
    • /
    • 제10권1호
    • /
    • pp.27-31
    • /
    • 2019
  • In this article, the properties of ${CO_2}^+(CO_2)_n$ clusters in a Paul ion trap have been investigated using mass-selective instability mode which conducted by chosen precursor ions, mainly $Ar^+$ and ${CO_2}^+$ produced by a mixture of Ar and $CO_2$. Exposure of ${CO_2}^+$ ions to $CO_2$ molecules, lead to the formation of ${CO_2}^+(CO_2)_n$ clusters. Here, Ar gas react as a buffer gas and lead to form ${CO_2}^+(CO_2)_n$ cluster by collisional effect.

Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

  • Park, Sehwan;Lee, Jihyeon;Cho, Soo Gyeong;Goh, Eun Mee;Lee, Sungman;Koh, Sung-Suk;Kim, Jeongkwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3659-3664
    • /
    • 2013
  • Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either $[M-H]^-$ for TNT and DNT or $[M]^{{\cdot}-}$ for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i.e., $[M+HCOO]^-$. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

Influence of Trap Passivation by Hydrogen on the Electrical Properties of Polysilicon-Based MSM Photodetector

  • Lee, Jae-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권6호
    • /
    • pp.316-319
    • /
    • 2017
  • A new approach to improving the electrical characteristics and optical response of a polysilicon-based metal-semiconductor-metal (MSM) photodetector is proposed. To understand the cause of current restriction in the MSM photodetector, modified trap mechanisms are suggested, which include interfacial electron traps at the metal/polysilicon interface and silicon dangling bonds between silicon crystallite grains. Those traps were passivated using hydrogen ion implantation with subsequent post-annealing. Photodetectors that were ion-implanted under optima conditions exhibited improved photoconductivity and reduced dark current instability, implying that the hydrogen bonds in the polysilicon influence the simultaneous decreases in the density of dangling bonds at grain boundaries and the trapped positive charges at the contact interface.