• 제목/요약/키워드: Ion sensor

검색결과 340건 처리시간 0.028초

콘크리트내 비래 염소이온 침투 모니터링을 위한 부식센서의 응답성능 평가에 관한 연구 (The study on Response of the Sensor for monitoring of Chloride Penetration in Concrete)

  • 신상헌;이현석;류화성;김보석;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.172-173
    • /
    • 2014
  • The study is used to verify the applicability of the sensor to monitor penetration of chloride into the concrete, like real coastal environment. After manufacturing the specimen adapt corrosion sensor for chloride penetration monitoring, chloride spray experiment was conducted. And then, It was checked the possibility of monitoring of the penetrated chloride by measuring the resistance of the corrosion sensor that was embedded in each depth of the concrete. Experimental results, it is confirmed that the corrosion resistance of the sensor was increased depending on the concentration of chloride. Therefore, it is estimated that the sensor is available for monitoring of chloride penetration.

  • PDF

나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용 (Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure)

  • 길민식;김민재;윤조희;장진우;이경균;최봉길
    • 공업화학
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2023
  • 본 논문에서는 용액의 이온 농도 측정이 가능한 나피온 폴리머(Nafion polymer) 코팅 기반 2상 금 전극의 임피던스(Impedance) 센서를 개발하였다. 스퍼터링(Sputtering) 공정을 통해서 제작된 금 전극의 표면을 나피온 폴리머를 사용하여 표면 개질 하였다. 상기 제작된 전극은 분극 현상 제어가 가능하여 전기화학적 신호를 안정적으로 측정할 수 있도록 하였다. 분광학과 전자주사현미경 관찰을 통하여 박막의 나피온 폴리머 코팅을 확인하였다. 나피온 코팅이 된 전극은 기존 금 전극에 비해 안정적인 임피던스 신호를 보여 주었으며, 표준 염화나트륨(NaCl) 용액 사용 시 임피던스 센서의 신뢰성 높은 검정 곡선(R2 = 0.983)을 나타내었다. 또한, 임피던스 센서는 상용화 전도도 장치와 인공 눈물의 이온 농도 측정 비교 실험을 진행하였으며, 유사한 결과값을 확인하였다.

개체 독립형 건축물 침입감지기 개발 (Development of Individual Trespassing Detector for Building)

  • 김명호
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.400-403
    • /
    • 2008
  • In this work, an individual trespassing detector using a PIR sensor to detect infrared rays only between the range of $9.4{\sim}10.4{\mu}m$ radiated from the body is proposed. This detector using FIR sensor detects not insect or object but human body, It doesn't restrict the inhabitant's behavior because the filter of pm sensor is designed to have face angle and the detector only detects the window area. The existing wide angle filter, RIR sensor, detects $30^{\circ}$ angle while the face angle filter sensor on this paper detects $11^{\circ}$ angle with 3cm of face angle filter from 2m of detecting distance. In case of interruption of electric power, 250mAh of lithium-ion battery has worked for 10 hours consuming 22mA in normal state. Meanwhile, in case of interruption of electric power, 250mAh of battery has worked for 4 hours consuming 60mA in trespassing detecting state. Projector, receptor, controller and alarm are put on one PCB in order to make it convenient to install without any special installation skill.

Novel Triiodide PVC-Based Membrane Sensor Based on a Charge Transfer Complex of Iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Shirvani Arani, Simindokht;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권11호
    • /
    • pp.1738-1742
    • /
    • 2005
  • In this study a novel triiodide ion-selective electrode based on a charge transfer complex of iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (ICT), as a membrane carrier was prepared. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ and 5.0 ${\times}$ $10^{-7}$ M, with a Nernstian slope of 58. 99 ${\pm}$ 0.3 mV $decade^{-1}$ and detection limit of 3.0 ${\times}$ $10 ^{-7}$ M. The potentiometric response of the proposed sensor is independent of the pH of the solution in the pH range of 3.0-10.0. The electrode possesses the advantages of short conditioning time, fast response time, and especially, very good selectivity over a large number of common organic and inorganic anions. The electrode can be used for at least 6 months without any considerable divergences in the potentials. It was used as an indicator electrode in potentiometric titration of triiodide ion with thiosulfate.

UV 임프린팅 공정을 이용한 금속막 필터제작 (Fabrication of Metallic Nano-Filter Using UV-Imprinting Process)

  • 노철용;이남석;임지석;김석민;강신일
    • 소성∙가공
    • /
    • 제14권5호
    • /
    • pp.473-476
    • /
    • 2005
  • The demand of on-chip total analyzing system with MEMS (micro electro mechanical system) bio/chemical sensor is rapidly increasing. In on-chip total analyzing system, to detect the bio/chemical products with submicron feature size, a filtration system with nano-filter is required. One of the conventional methods to fabricate nano-filter is to use direct patterning or RIE (reactive ion etching). However, those procedures are very costly and are not suitable fur mass production. In this study, we suggested new fabrication method for a nano-filter based on replication process, which is simple and low cost process. After the Si master was fabricated by laser interference lithography and reactive ion etching process, the polymeric mold was replicated by UV-imprint process. Metallic nano-filter was fabricated after removing the polymeric part of metal deposited polymeric mold. Finally, our fabrication method was applied to metallic nano-filter with $1{\mu}m$ pitch size and $0.4{\mu}m$ hole size for bacteria sensor application.

Nanoplasmonic Spectroscopic Imaging and Molecular Probes

  • 최연호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.85-85
    • /
    • 2013
  • Label-free, sensitive and selective detection methods with high spatial resolution are critically required for future applications in chemical sensor, biological sensor, and nanospectroscopic imaging. Here I describe the development of Plasmon Resonance Energy Transfer (PRET)-based molecular imaging in living cells as the first demonstration of intracellular imaging with PRET-based nanospectroscopy. In-vivo PRET imaging relied on the overlap between plasmon resonance frequency of gold nanoplasmonic probe (GNP) and absorption peak frequencies of conjugated molecules, which leads to create 'quantized quenching dips' in Rayleigh scattering spectrum of GNP. The position of these dips exactly matched with the absorption peaks of target molecules. As another innovative application of PRET, I present a highly selective and sensitive detection of metal ions by creating conjugated metal-ligand complexes on a single GNP. In addition to conferring high spatial resolution due to the small size of the metal ion probes (50 nm in diameter), this method is 100 to 1,000 folds more sensitive than organic reporter-based methods. Moreover, this technique achieves high selectivity due to the selective formation of Cu2+complexes and selective resonant quenching of GNP by the conjugated complexes. Since many metal ion ligand complexes generate new absorption peak due to the d-d transition in the metal ligand complex when a specific metal ion is inserted into the complex, we can match with the scattering frequency of nanoplasmonic metal ligand systems and the new absorption peak.

  • PDF

머신러닝 기반 스마트 단말기 Lithium-Ion Cell의 잔량 추정 방법의 실증적 연구 (An Empirical Study on Machine Learning based Smart Device Lithium-Ion Cells Capacity Estimation)

  • 장성진
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.797-802
    • /
    • 2020
  • 지난 몇 년 동안 스마트 폰을 비롯한 다양한 스마트 기기들은 휴대성을 기반으로 사용자의 요구에 의해 지속적으로 성능이 향상 되고 있다. 유비쿼터스 컴퓨팅 (Ubiquitous Computing) 환경과 센서 네트워크 (Sensor network)등의 다양한 망 접속 기술로 인하여 휴대성을 기반으로 하는 단말기들이 다양하게 보급되어 사용되고 있다. 스마트 단말들은 사용 중에 보다 안정적인 동작을 위하여 에너지 모니터링을 세밀하게 할 수 있는 기술이 필요하게 되었다. 소형 경량화 된 스마트 단말기는 다양한 멀티미디어 작업으로 인하여 단말 운용 중에 전원 부족 문제가 발생하게 된다. 이와 같은 상황을 미리 방지하고 안정적인 단말 운용을 위해서 기존에 다양한 추정 하드웨어가 개발 되었다. 그러나 잔량 추정을 하는 방법이나 성능이 비교적 우수하지 못하였다. 본 논문에서는 스마트 단말의 운용 중에 발생 할 수 있는 잔여 잔량 문제를 미리 예측하여 보다 안정적인 운용을 위한 리튬이온 셀의 잔량 추정 방법을 머신러닝에 기초를 두고 연구 하였다. 기존의 하드웨어적인 추정 방법이 아니라 사용 중인 리튬이온 셀의 특성을 머신러닝 기법을 이용한 학습 알고리즘으로 학습 시키고 최적화된 결과를 추정하여 적용 하고자 한다.

Highly Selective Triiodide Polymeric Membrane Electrode Based on Tetra(p-chlorophenyl)porphyrinato Manganese (Ⅲ) Acetate

  • Farhadi, Khalil;Shaikhlouei, Hossain;Maleki, Ramin;Sharghi, Hashem;Shamsipur, Mojtaba
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1635-1639
    • /
    • 2002
  • A new solvent polymeric membrane sensor based on tetra(p-chlorophenyl)porphyrinato manganese (III) acetate is described which demonstrates excellent selectivity toward the triiodide ion. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ M and 7.0 ${\times}$$10^{-6}$M with a Nernstian slope of $-59.6{\pm}1$ mV per decade and a detection limit of 5.0 ${\times}$$10^{-6}$M. The proposed sensor revealed good selectivities for triiodide over a wide variety of other anions and could be used in a pH range 2-9. The electrode can be used for at least two months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of the triiodide and As(III) ions.

$\alpha$-Fe$_2$O$_3$의 가스감지특성에 미치는 황산이온의 영향 (Effects of Sulfate Ion the Gas Sensing Characteristic of the $\alpha$-Fe$_2$O$_3$)

  • 양천희
    • 한국안전학회지
    • /
    • 제4권1호
    • /
    • pp.71-74
    • /
    • 1989
  • The $\alpha$-Fe$_2$O$_3$ gas sensor, prepared by the precipitation of Fe(OH)$_3$ from a solution of iron(III) sulfate and tin (IV) chloride, was composed of fine particles and was superior in sensitivity to other $\alpha$-Fe$_2$O$_3$. The gas sensitivity was found to depend on the amounts of remaining sulfate ion the microstructure and a small amount of iron(II) species generated through the reduction of $\alpha$-Fe$_2$O$_3$. The sensing mechanism of $\alpha$-Fe$_2$O$_3$gas sensor was confirmed to be due to the reduction of $\alpha$-Fe$_2$O$_3$ to the low resistive Fe$_3$-xO$_4$ by combustible gas and to depend on the crystral structure.

  • PDF

수질환경에서 광섬유 센서의 구리 이온 감지 물질로서 8-Hydroxyquinoline 합성유도체의 광학적 반응 특성 연구 (Study on Optical Characteristics of 8-Hydroxyquinoline Synthesized Derivative as Sensing Material of the Fiber-Optic Copper Ion Sensor in Aqueous Environment)

  • 김범규;박병기
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.100-105
    • /
    • 2017
  • 수질환경에서 구리이온을 검출하기 위하여 광섬유 센서의 구리 이온 감지 물질로 8-Hydroxyquinolin-2carboxaldehyde와 4-Aminoantipyrine으로 합성된 8-Hydroxyquinoline 합성유도체에 대해 광학적 반응 특성을 조사하였다. 실험은 광섬유를 이용한 측정시스템을 이용하여 수용액에 용해된 구리 이온의 농도에 대해 합성유도체에 의한 흡광도와 관계를 평가하기 위하여 수행되었다. 8-Hydroxyquinoline 합성유도체는 수질 환경에서 다양한 금속 이온들 중에서 구리 이온에 대해 노란색에서 붉은색으로 변화되는 높은 발색 현상을 나타냈으며 530 nm의 고유 흡광 파장을 보였다. 제작된 합성유도체의 Cu 이온에 대한 선택성을 평가하기 위하여 Hg 이온의 영향을 조사하였다. Cu와 Hg 이온의 다양한 농도 비 (Cu:Hg ratio 0.05부터 20까지)에서 흡광도를 측정한 결과, Cu 이온의 농도 증가에 따라 530nm에서 흡광도가 증가하는 경향을 보였다. 구리 이온의 고유 흡광 파장인 530 nm에서 합성 유도체에 의한 흡광도 세기는 구리 이온의 로그 농도에 선형으로 비례하였다. 따라서 8-Hydroxyquinoline합성유도체는 광섬유 센서의 구리 이온 감지 물질로 우수한 특성을 보임을 실험적으로 확인할 수 있었다.