• 제목/요약/키워드: Ion sensor

검색결과 339건 처리시간 0.023초

Improvement of reliability of an ISFET pH-meter by employing multiple sensors

  • 장기석;조병욱;김창수;최상복;손병기
    • 센서학회지
    • /
    • 제6권2호
    • /
    • pp.131-136
    • /
    • 1997
  • The ISFET(ion sensitive field effect transistor), a semiconductor ion sensor, has many advantages over conventional ion sensors. Various single-sensor type ISFET pH-meters have been developed. However, they could not be applied in fields because their performances are directly affected by the sensor condition. With only one sensor, the system could be easily damaged from environmental factors, and reliability of it is decreased. Therefore, a 4-channel PH-meter system is proposed to improve the reliability of ISFET pH-meter. It has 4 ISFETS as ion sensor, and a software which contains a new calibration and measurement algorithm appropriate to the system. The reliability of the system was proved by measuring hydrogen ion concentration in the pH standard solutions and buffer solutions.

  • PDF

콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete)

  • 이현석;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.143-152
    • /
    • 2014
  • 본 연구에서는 콘크리트내로 침투하는 염소이온을 모니터링하기 위하여, 스크린프리트 기법으로 염소이온 반응형 부식센서를 개발하고, 센서의 세선 수가 부식반응도 및 민감도에 미치는 영향을 실험을 통하여 정량적으로 분석하였다. 개발된 부식센서를 이용하여 염소이온량에 따라 부식 반응도을 확인하였으며, 센서의 파괴정도에 따른 저항변화에서는 단선형 센서보다 다선형 센서에서 큰 저항 변화를 나타내었다. 또한, 부식센서는 NaCl 수용액의 농도가 높은 만큼 센서의 저항변화가 크고, 콘크리트 내에서 센서 종류에 따른 부식저항은 단선형보다 다선형에서 민감도가 높게 나타났으며, 센서의 매설깊이가 클수록 저항변화 사이클 (cycle)은 증가하였다. 이상의 결과로, 본 연구에서 개발된 부식센서는 염분에 대한 부식반응과 민감도, 저항의 변화를 감지할 수 있었으며, 특히 7세선이 우수한 결과를 나타내어, 염분의 침투정도를 모니터링 하는데 가장 적합하다고 판단된다.

수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발 (Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients)

  • 김기영;이상봉;장영창
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

The Fluorescent 7-Aminodipyrido[3,2-a:2',3'-c] phenazine(7-amino-dppz) Functionalized as an Europium Ion ($Eu^{3+}$) Sensor

  • Choi, Chang-Shik;Lee, Ki-Hwan
    • Rapid Communication in Photoscience
    • /
    • 제1권2호
    • /
    • pp.31-33
    • /
    • 2012
  • The Fluorescent 7-aminodipyrido[3,2-a:2',3'-c]phenazine (7-amino-dppz, 1) is functionalized as an europium ion ($Eu^{3+}$) sensor, which showed the effective emission quenching when europium cation is chelated to the bpy site of 1 compound. The complexation ratio indicated that the 1 compound forms a 1 : 1 complex with $Eu^{3+}$.

Titanium Acetylacetonate as an Excellent Ion-Carrier in Construction of Iodide Sensor

  • Ganjali, Mohammad Reza;Daftari, Azadeh;Mizani, Farhang;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.23-26
    • /
    • 2003
  • Titanium acetylacetonate was used in the construction of a PVC-based membrane electrode. This sensor shows very good selectivity for iodide ion over a wide variety of common inorganic and organic anions. It exhibits Nernstian behavior with a slope of 59.1 mV per decade. The working concentration ranges of the sensor are with a detection limit of $3.0\;{\times}\;10^{-6}\;M$. The response time of the sensor is very fast (<8 s), and can be used for at least twelve weeks in the pH range of 4.0-9.2. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutylphthalate, 3% titanium acetylacetonate and 2% hexadecyltrimethylammonium bromide. The proposed sensor was successfully applied as an indicator electrode for titration of iodide with silver ion.

Alizarin Red S modified electrochemical sensors for the detection of aluminum ion

  • Chang, Seung-Cheol
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.421-427
    • /
    • 2010
  • Alizarin Red S modified screen printed carbon electrodes were developed for the electrochemical detection of aluminum ion. The electrodes developed use screen-printed carbon electrodes(SPCEs) coupled with chemical modification with an organic chelator, Alizarin Red S(ARS), for aluminum ion detection in aqueous solution. For sensor fabrication ARS was directly immobilized on the surface of SPCEs using PVA-SbQ(The poly(vinyl alcohol) bearing stryrylpyridinium groups). Aluminum concentrations were indirectly estimated by amperometric determination of the non-complexed ARS immobilized on the electrodes, after its complexation with aluminum. The sensitivity of the sensor developed was $3.8\;nA{\mu}M^{-1}cm^{-2}$ and the detection limit for aluminum was $25\;{\mu}M$.

전기자동차용 리튬이온전지를 위한 SOC 추정 및 센서 고장검출 (Estimation of State-of-charge and Sensor Fault Detection of a Lithium-ion Battery in Electric Vehicles)

  • 한만유;이기상
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1085-1091
    • /
    • 2014
  • A model based SOC estimation scheme using parameter identification is described and applied to a Lithium-ion battery module that can be installed in electric vehicles. Simulation studies are performed to verify the effect of sensor faults on the SOC estimation results for terminal voltage sensor and load current sensor. The sensor faults should be detected and isolated as soon as possible because the SOC estimation error due to any sensor fault seriously affects the overall performance of the BMS. A new fault detection and isolation(FDI) scheme by which the fault of terminal voltage sensor and load current sensor can be detected and isolated is proposed to improve the reliability of the BMS. The proposed FDI scheme utilizes the parameter estimation of an input-output model and two fuzzy predictors for residual generation; one for terminal voltage and the other for load current. Recently developed dual polarization(DP) model is taken to develope and evaluate the performance of the proposed FDI scheme. Simulation results show the practical feasibility of the proposed FDI scheme.

능동형 박막 광도파로 칼슘 이온 센서의 개발 (Development of Active thin Film Optical Waveguide $C^{2+}$ -ion Sensor)

  • 이수미;강신원
    • 전자공학회논문지SC
    • /
    • 제37권4호
    • /
    • pp.49-54
    • /
    • 2000
  • 고분자 이온 감응막을 광도파로로 이용한 새로운 형태의 센서소자를 제작하여 칼슘이온의 농도 변화에 따른 그 특성을 평가하였다. 광도파로 소자는 실리카 유리기판에 기존의 반도체 사진식각법 (photolitho-graphy)을 이용하여 도파로가 형성되어질 부분을 에칭한 후 감지막을 스핀코팅법으로 코팅하여, 그 자체를 도파로로 이용한 고속 응답의 새로운 형태의 센서소자를 제작하였다. 도파로로 사용된 감지막은 칼슘이온에 대해 특이성을 가지는 변색성 이온감응물질인 ETH5294, 중성이온감응물질인 K23El, anionic site인 NaTm(CF/sub 3/)/sub 2/PB, 가소제인 DOP 및 PVC-PVAC-PVA 폴리머를 THF 용매에 녹여 스핀 코팅법으로 제작하였다. 여러 가지 변수에 따른 센서의 특성을 평가하기 위하여 도파로의 두께(즉, 감지막의 두께), 변색성 이온감응물질의 농도, 각 모드 변화에 따른 센서의 감응특성을 비교 평가하였다. 제작된 센서는 칼슘이온에 대해 1×10­6∼1M의 측정 범위를 가지며, 1×10­⁴∼1×10­¹M 영역에서 선형성을 가지며, 기존의 광학적 측정 방법인 분광분석법에 비해 높은 감도를 나타냄을 확인하였다.

  • PDF

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.