• Title/Summary/Keyword: Ion selective electrodes

Search Result 102, Processing Time 0.022 seconds

Ion-Selective Electrodes for the Determination of Alverine (Alverine의 정량을 위한 Ion-Selective Electrodes)

  • Lee, Eun-Yup;Kim, Ki-Myo;Kim, Sung-Jin;Hur, Moon-Hye;Ahn, Moon-Kyu
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.79-84
    • /
    • 1995
  • Ion-selective poly(vinyl chloride) membrane electrodes for the determination of the anticholinergic drug alverine in pure substances is described. Ion-pair complex of alverine with anionic counter ion acid red 97 is investigated as electroactive compound for the electrode membrane. On the optimal composition of membrane, its slope was 55.35mV/decade, relative standard deviation was 0.61 and lower limit of linear range was $1.0{\times}10^{-5}M$. The observed potentiometric selectivity coefficient was -2.625 toward methylephedrine and -2.216 toward histidine. We can got the stable potential at pH 7.0~4.0. Response time was 20~30 seconds for solutions${\leq}10^{-4}M$, about 10 seconds for solutions ${\geq}10^{-4}M$ of these compounds.

  • PDF

Polymeric Membrane Cesium-Selective Electrodes Based on Quadruply-bridged Calix[6]arenes

  • Choe, Eun Mi;O, Hye Jin;Go, Seung Hwa;Choe, Yong Guk;Nam, Gye Chun;Jeon, Seung Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1345-1349
    • /
    • 2001
  • New quadruply-bridged calix[6]arenes (I-V) have been studied as cesium selective ionophores in poly(vinyl chloride) (PVC) membrane electrodes. PVC membranes were prepared with dioctyl sebacate (DOS) or 2-nitrophenyl octyl ether (o-NPOE) as the sol vent mediator and potassium tetrakis(p-chlorophenyl)borate as the lipophilic salt additive. These ionophores produced electrodes with near-Nernstian slope. The selectivity coefficients for cesium ion with respect to alkali, alkaline earth and ammonium ions have been determined. The lowest detection limit (logaCs+ = -6.3) and the higher selectivity coefficient (logkpotCs+,Rb+ = -2.1 by SSM, -2.3 by FIM for calix[6]arene I) for Cs+ have been obtained for membranes containing quadruply-bridged calix[6]arenes (I, Ⅱ, Ⅲ), which have no para t-butyl substituents on the bridging benzene ring.

Determination of Basic Drugs with Ion-Selective Membrane Electrodes Using Ion-Exchanger (이온교환체 이온선택성 전극을 이용한 염기성의약품 정량)

  • 이지연;정문모;허문회;김은정;안문규
    • YAKHAK HOEJI
    • /
    • v.43 no.3
    • /
    • pp.289-293
    • /
    • 1999
  • Many poly (vinyl chloride : PVC) membrane electrodes were investigated for the determination of basic drugs, chlorpromazine, amitriptyline, nortriptyline, etc. These electrodes are based on the use of the ion-association complexes of the basic drugs with eriochrome cyanine R, chromoxane cyanine, chrome azurol S and picric acid as ion-exchange sites in a plasticized PVC matrix. All ion-exchangers except picrate complex were not proper for use, because those complexes in plasticized membrane were excluded into aqueous working solution. These drug electrodes show excellent Nernstian responses in the concentration ranges $10^{-2}~10^{-6}$ mol $dm^{-3}$. Their selectivity with respect to each other, as well as their work-able pH range have been investigated. The major advantages of the proposed methods are their simplicity and speed.

  • PDF

Development of Ion-Selective Electrodes for Agriculture

  • Yang-Rae Kim
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.153-153
    • /
    • 2022
  • There is a growing need to develop ion sensors for agriculture. As a result, several technologies have been developed, such as colorimetry, spectrophotometry, and ion-selective electrode (ISE). Among them, ISE has some advantages compared to others. First, it does not require pre-treatment processes and expensive equipment. Second, it is possible for the portable detection system by introducing small-sized electrodes. Finally, real-time and multiple detections of several ions are pursued. It is well-known that N, P, and K nutrients are critical for crop growth. With the development of agriculture techniques, the importance of soil nutrient analysis has attracted much attention for cost-effective and eco-friendly agriculture. Among several issues, minimizing the use of fertilizers is significant through quantitative analysis of soil nutrients. As a result, it is highly important to analyze certain nutrients, such as N (ammonium ion, nitrate ion, nitrite ion), P (dihydrogen phosphate ion, monohydrogen phosphate ion), and K (potassium ion). Therefore, developing sensors for accurate analysis of soil nutrients is highly desired. n this study, several ISEs have been fabricated to detect N, P, and K. Their performance has been intensively studied, such as sensitivity, selectivity coefficient, and concentration range, and compared with commercialized ISEs. In addition, preliminary tests on the in-situ N, P, and K monitoring have been conducted inside the soil.

  • PDF

Polymeric Iodide-ion Selective Electrodes Based on Urea Derivative as an Ionophore

  • Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.12
    • /
    • pp.1985-1988
    • /
    • 2006
  • The polymeric membrane electrodes based on urea derivative as an ionophore were prepared and studied for the iodide-ion selective electrode. This membrane exhibits a linear stable response over a wide concentration range ($1.0\;{\times}\;10^{-5}\sim1.0\;{\times}\;10^{-2}$) with a slope of -57.7 mV/decade, a detection limit of log[$I^-$] = -5.63, and a selectivity coefficient for iodide against perchlorate anion (log$K^{pot}_{I^-,j}$ = -1.42). The selectivity series of the membrane gives the follow as $I^-$ > $SCN^-$, $Sal^-$ > $ClO_4^-$ > $NO_3^-$ > $Br^-$ > $NO_2^-$ > $Cl^-$ > $F^-$. The proposed electrode showed good selectivity and response for iodide anion over a wide variety of other anions in pH 5.0 buffer solutions.

Determination of Nitrate in Chromium Plating Solution with Nitrate-Selective Electrodes

  • 강유라;이원;허황;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.221-226
    • /
    • 1995
  • A method for determining nitrate in post treatment chromium plating solutions with PVC-based nitrate-selective electrodes is described. PVC-based nitrate-selective membranes which contain TDMANO3 ion-exchanger in PVC/NPOE, PVC/DOA or PVC/DBP matrices, and a commercially available Corning electrode (No. 476134) have been compared in respect of their detection limits, response slopes, selectivities at various pHs, and dynamic response to the hydrochromate ion in basic condition. The PVC/DBP/TDMANO3 membrane electrode was chosen as the ISE detector for the determination of nitrate in the presence of hydrochromate interference. The amount of nitrate in real post treatment chromium plating solution could be determined successfully with this electrode in both static and flow-injection measurements when the sample was properly diluted with an alkaline buffer.

Application of a. Strip Ion-Selective Electrode Sensor for Hydroponic Nutrient Solution Analysis - NO3 Analysis - (양액의 영양분 분석을 위한 Strip형 이온선택성전극 센서 의 응용 -NO3 이온 분석 -)

  • 김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.335-342
    • /
    • 2003
  • A simple disposable thick-film potentiometric strip has been developed and evaluated for hydroponics application. The strip consisted of low ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, and magnesium were measured with specially designed 16-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The thick-film sensors exhibit linear relationships over five concentration decades. The concentration of N $O_3$ - ion in standard solution can be determined by direct potentiometric measurements without any conditioning before measurements. However, measurement of $K^{+}$, N $H_4$$^{+}$, and $Mg^{2+}$ ionic concentrations in nutrient solutions seems not feasible.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.