• Title/Summary/Keyword: Ion range

Search Result 1,717, Processing Time 0.026 seconds

Fluoride content of bottled water available in South Korea (국내 시판 생수의 불소 이온농도 측정)

  • Kim, Ji-Soo;Nam, Yong-Tae;Kim, Se-Yeon;Jun, Eun-Joo;Kim, Jin-Bom;Jeong, Seung-Hwa
    • Journal of Korean Academy of Oral Health
    • /
    • v.42 no.4
    • /
    • pp.199-203
    • /
    • 2018
  • Objectives: The market for bottled water is increasing steadily in South Korea. Bottled water contains several naturally occuring minerals, such as calcium, magnesium, sodium, and fluoride. Fluoride is proven to be effective in preventing dental caries. In South Korea, the maximum permissible concentration of fluoride is 2 ppm for bottled water and 1.5 ppm for tap water. The aim of this study was to investigate the fluoride content of different commercially available brands of bottled water in South Korea, and compare the measured fluoride concentration to the concentration written on the label of each brand of bottled water. Methods: Twenty-seven of the 59 different brands of bottled water produced in South Korea were investigated in this study. Three bottles of each brand were purchased from supermarkets, marts, and convenience stores in each region of Korea in August 2016. For each bottled water brand, the fluoride content was measured three times using a fluoride-ion selective electrode (Orion ionplus Fluoride Electrode 9609, Orion Research, USA). The calibration curve was generated using 0.2 and 2 ppm standard solutions, and confirmed using a 1 ppm standard solution. Results: The mean fluoride content of the 27 brands of bottled water was $0.374{\pm}0.332mg/L$ (range=0.040 to 1.172 mg/L). The fluoride content was labeled by the manufacturer, on each of the tested brands of bottled water. In eight brands, the labeled fluoride content differed from the experimental data. The minimum to maximum fluoride content measured from 10 brands showed a variation of 0.3 mg/L or more when compared to the labeled fluoride content. Conclusions: This study investigated the fluoride content of various brands of bottled water produced in South Korea and compared the measured fluoride levels with fluoride information on the bottle labels. To ensure that consumers are suitably informed regarding their exposure to fluoride, correct labelling of fluoride content in bottled water is important.

Antioxidant Effect of Anserine Extracted from Salmon (Oncorhynchus keta) (연어(Oncorhynchus keta) 추출 anserine의 항산화 효과)

  • Min, Hye-Ok;Song, Ho-Su
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.396-403
    • /
    • 2019
  • Ion-exchange chromatography and ultrafiltration were used to extract anserine from salmon (Oncorhynchus keta). The salmon anserine showed DPPH radical scavenging activity in the range of 7.30% to 31.05% in a dose-dependent manner. This reducing power of salmon anserine also increased as the concentration increased. Metal chelate activity, superoxide dismutase - like activity, and thiobarbituric acid reactive substances assay showed similar results. The anserine also suppressed the increment of the peroxide value and linoleic acid during storage periods. These results suggest that salmon anserine might be useful as a natural antioxidant in various foodstuffs.

Fabrication and the Electrochemical Characteristics of Petroleum Residue-Based Anode Materials (석유계 잔사유 기반 음극재 제조 및 그 전기화학적 특성)

  • Kim, Daesup;Lim, Chaehun;Kim, Seokjin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.496-501
    • /
    • 2022
  • In this study, an anode material for lithium secondary batteries was manufactured using petroleum-based residual oil, which is a petroleum refining by-product. Among petroleum-based residual oils, pyrolysis fuel oil (PFO), fluidized catalyst cracking-decant oil (FCC-DO), and vacuum residue (VR) were used as carbon precursors. The physicochemical characteristics of petroleum-based residual oil were confirmed through Matrix-assisted laser desorption/ionization Time-of-Flight (MALDI-TOF) and elemental analysis (EA), and the structural characteristics of anode materials manufactured from residual oil were evaluated using X-ray crystallography (XRD) and Raman spectroscopic techniques. VR was found to contain a wide range of molecular weight distributions and large amounts of impurities compared to PFO and FCC-DO, and PFO and FCC-DO exhibited almost similar physicochemical characteristics. From the XRD analysis results, carbonized PFO and FCC-DO showed similar d002 values. However, it was confirmed that FCC-DO had a more developed layered structure than PFO in Lc (Length of a and c axes in the crystal system) and La values. In addition, FCC-DO showed the best cycle characteristics in electrochemical characteristics evaluation. According to the physicochemical and electrochemical results of the petroleum-based residual oil, FCC-DO is a better carbon precursor for a lithium secondary battery than PFO and VR.

Development of a Centrifugal Microreactor for the Generation of Multicompartment Alginate Hydrogel (다중 알긴산 입자제조를 위한 원심력 기반 미세유체 반응기 개발)

  • Ju-Eon, Jung;Kang, Song;Sung-Min, Kang
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.23-29
    • /
    • 2023
  • Microfluidic reactors have been made to achieve significant development for the generation of new functional materials to apply in a variety of fields. Over the last decade, microfluidic reactors have attracted attention as a user-friendly approach that is enabled to control physicochemical parameters such as size, shape, composition, and surface property. Here, we develop a centrifugal microfluidic reactor that can control the flow of fluid based on centrifugal force and generate multifunctional particles of various sizes and compositions. A centrifugal microfluidic reactor is fabricated by combining microneedles, micro- centrifuge tubes, and conical tubes, which are easily obtained in the laboratory. Depending on the experimental control param- eters, including centrifuge rotation speed, alginate concentration, calcium ion concentration, and distance from the needle to the calcium aqueous solution, this strategy not only enables the generation of size-controlled microparticles in a simple and reproducible manner but also achieves scalable production without the use of complicated skills or advanced equipment. Therefore, we believe that this simple strategy could serve as an on-demand platform for a wide range of industrial and academic applications, particularly for the development of advanced smart materials with new functionalities in biomedical engineering.

Short Culm and Early Maturing Mutants Induced by Gamma Irradiation in Rice I . Mutation Rate and Variability (감마선 조사에 의한 수도의 단간 및 조숙돌연변이체 I. 변이체의 출현빈도 및 변이분포)

  • Lee, Young-Il;Shin, In-Chul;Hong, Byeong-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.4
    • /
    • pp.378-383
    • /
    • 1989
  • For selection of mutants two rice varieties, Sangpungbyeo and Seomjinbyeo, were irradiated with 20 kR and 25 kR of gamma rays. One panicle per each plant was harvested in Ml, and single needling per hill was planted for M2 and M3 generations. Mutations for short culm, earliness and the major traits were examined. 1. The mutation rates were varied with the rice varieties and the doses of radiation, higher in Sangpungbyeo and 25kR than in Seomjinbyeo and 20 kR, respectively. 2. The rates in Sangpungbyeo with the 20 kR and 25 kR were 1.10% and 1.47%. respectively and those of Seomjinbyeo were 0.51% and 1.25%, respectively. 3. The culm lengths of short-culm mutants derived from Sangpungbyeo and Seomjinbyeo were reduced about 10% compared to their mother varieties, especially it was possible to select the dwarf mutants reducing 57% and 40% of culm length in Sangpungbyeo and Seomjinbyeo, respectively with the dose of 25 kR irradiation. 4. The range of heading date of the mutant ion in the M3 generation was comparatively wide. Many earliness mutants shortened about 7 days were selected as compared with their mother varieties, some mutants of the irradiated group had early matured by 20 days and 30 days, respectively in both Seomjinbyeo and Sangpungbyeo.

  • PDF

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Simultaneous GC/MS Analyses of Organic acids and Amino acids in Urine using TMS-TFA derivative (TMS-TFA 유도체화를 이용한 소변여지 중 유기산과 아미노산의 GC/MS 동시분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.107-114
    • /
    • 2006
  • Early diagnosis and medical intervention are critical for the treatment of patients with metabolic disorders. A rapid analytical method was developed for simultaneous quantification of organic acids and amino acids in urine without labor-intensive pre-extraction procedure showing high sensitivity and specificity. A new method consisted of simple two-step trimethylsilyl (TMS)-trifluoroacetyl (TFA) derivatization using GC/MS-selective ion monitoring (SIM). Filter paper urine specimens were dried under nitrogen after being fortified with internal standard (tropate) in a mixture of distilled water and methanol. Methyl orange was added to the residue as indicator reagent. Silyl derivative of carboxylic functional group was followed by trifluoroacetyl derivative for amino functional group. N-methyl-N-(trimethylsilyl-trifluoroacetamide) and N-methyl-bistrifluoroacetamide were consecutively added and heated for 15-20 min at $65^{\circ}C-70^{\circ}C$, for TMS-TFA derivative, respectively. This reactant was analyzed by GC/MS-SIM. Linear dynamic range showed 0.001-50 mg with the detection limit of (S/N=3) 10-200 ng, and the quantification limit of 80-900 ng in urine. Correlation coefficient of regression line was 0.994-0.998. When the method was applied to the patients 'urine, it clearly differentiated the normal from the patient with metabolic disorder. The study showed that the developed method could be the method of choices in rapid and sensitive screening for organic aciduria and amino acidopathy.

Measurement of heavy metals in antarctic soil at the king sejong station: application of isotope dilution inductively coupled plasma mass spectrometry (동위원소희석 ICP-MS분석법에 의한 남극 세종기지 주변 토양의 중금속 측정)

  • Suh, Jung-Ki;Hwang, Euijin;Min, Hyung Sik
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.364-374
    • /
    • 2008
  • Antarctic Environmental Monitoring Handbook' was published by COMNAP/SCAR in 2000. The standardized method described in this handbook is recommended for monitoring of antarctic environment. High pressure bomb technique in this guide was used to decompose soil samples. In compliance with this guide book, high pressure bomb technique was applied to decompose the antarctic soil sampled at the King Sejong Station. An Isotope Dilution-Inductively Coupled Plasma-Mass Spectrometry (ID-ICP-MS) was applied to determine mass concentrations of Pb, Cu and Zn in the soil. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of NIST 2702 (marine sediment). The analytical results agreed with certified value within the range from 99.5~100.8%. Matrix separation was necessitated for the determination of Cu and Zn by Chelex 100 ion exchange resin. As a result, the average mass concentrations of Pb, Cu and Zn which are suspected to be caused by anthropogenic pollution were 332.9 mg/kg, 95.6 mg/kg and 115.3 mg/kg, respectively. Those for the metals sampled in the soils of the remote regions from the station were 28.1 mg/kg, 101.8 mg/kg and 115.6 mg/kg, respectively.

Simultaneous analysis of residual glucocorticoids in egg by LC/MS/MS (LC/MS/MS를 이용한 계란 중 잔류 글루코코티코이드의 동시분석)

  • Jang, Mi-Ae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.326-335
    • /
    • 2009
  • A specific analytical method able to identify and quantify traces of six glucocorticoids residues in eggs were developed. The extraction and clean-up parameters for simultaneous analysis were evaluated and HPLC and spectrometric conditions were also established. For determination of glucocorticoids, 5 g of egg was transferred into a test tube, adjusted pH 5.2 with acetate buffer and was $\beta$-glucuronidase/arylsulfatase from Helix pomatia added. The mixture was centrifuged and supernatant was extracted twice with 20 mL n-hexane. The extraction was performed with HLB cartridge using methanol, followed by clean-up with silica cartridge using methanol/ethyl acetate (4/6, v/v). The analytes were determined by HPLC/ESI-MS/MS operating in the negative ion mode. Validation studies with fortified egg samples for established method were performed. The result of method validation gave good efficiency, linearity, accuracy and precision. The correlation coefficients ($r^2$) of the calibration curves appeared to be higher than 0.99 in egg, indicating excellent linearity. LOD was ranged 0.09 to $0.17{\mu}g/kg$, and recoveries for most compounds were in the range of 55.7-69.8%. This method can be used to determine ${\mu}g/kg$ levels of glucocorticoids in eggs.

Purification of antigenic proteins of Paragonimus westermani and their applicability to experimental cat paragonimiasis (폐(肺)디스토마(Paragonimus westermani) 감염(感染) 고양이 혈청(血淸)에 대(對)한 ELISA 항체가(抗體價)의 의의(意義))

  • Choi, Won-Young;Yoo, Jae-Eul;Nam, Ho-Woo;Choi, Hyung-Rak
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.177-186
    • /
    • 1986
  • This study was designed to evaluate the partially purified antigens which were fractionated from crude extract of Paragonimus westermani and to monitor the enzyme-linked immunosorbent assay (ELISA) in experimental cat paragonimiasis during the course of infection as well as before and after chemotherapy. Crude extract of 6-month-old adult P. westermani was fractionated to 5 antigens by successive applications of ammonium sulfate precipitation, ion exchange chromatography and gel filtration. And the cats, 10 in each group, were infected with 60, 30, 15, and 5 metacercariae, then the half of each group was treated with praziquantel 2 times in one day of 100mg per kilogram of weight on 150 days after the infection. Sera were collected every 10 days. ELISA was performed with the concentration of $2{\mu}g/ml$ antigen, 100 times diluted sera and 1,000 times diluted alkaline phosphatase conjugated anti-cat IgG. The results were as follows: 1. Absorbance by ELISA with proteins precipitated by differential concentration of ammonium sulfate was the highest at $51{\sim}65%$ precipitate (PA2), followed by $0{\sim}50%$ precipitate (PAl), $66{\sim}80%$ precipitate (PA3), and $81{\sim}90%$ precipitate (PA4). Unprecipitated protein over 90% ammonium sulfate (PA5) showed the lowest antigenicity. 2. Fractionation of PA1, PA2, and PA3 through the DEAE-cellulose column did not differentiate the antigenic proteins. 3. By passing through the Sephadex G-200 column, PA1 and PA2 were fractionated to high molecular weight proteins and those of low molecular weight which showed high absorbance by ELISA (PA1-I, II and PA2-I, II). But PA3 was shown to have a fraction of high molecular weight proteins (PA3-I) which showed high antigenicity. 4. SDS-polyacrylamide gel electrophoresis of PA1-I, P A1-II, PA2-I, PA2-II, PA3-I, and crude extract was performed. Fraction PA1-I was composed of proteins which had the molecular weight of 270 kilodaltons(KD) to 196 KD; of them 220KD protein was major band. Fraction PA2-I was composed of $255{\sim}225\;KD$, and PA3-I, $255{\sim}240\;KD$, respectively. Fraction PA1-II and fraction PA2-II consisted of 30 KD proteins. 5. Absorbance by ELISA began to increase within $10{\sim}20$ days after the infection and reached the highest on $140{\sim}180$ days, then made plateau thereafter. 6. Absorbance by ELISA decreased after praziquantel treatment. In 60 metacercariae infection group, the absorbance had been decreasing, but remained within the positive range during observation period, while those of 30, 15, and 5 metacercariae infection groups turned to negative range. 7. Fraction PA1-II showed the highest antigenicity in ELISA, then fraction PA2-I, fraction PA1-I, fraction PA2-II, fraction PA3-I and crude extract followed. In early phase of infection, the absorbance of fraction PA1-II showed more rapid increase than those of the other fractions and it came to positive range at $20{\sim}30$ days after infection.

  • PDF