• 제목/요약/키워드: Ion pump

검색결과 111건 처리시간 0.025초

A Preliminary Analysis of Large Loss-of-Coolant Induced by Emergency Core Coolant Pipe Break in CANDU-600 Nuclear Power Plant

  • Ion, Robert-Aurelian;Cho, Yong-Jin;Kim, In-Goo;Kim, Kyun-Tae;Lee, Jong-In
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.435-440
    • /
    • 1996
  • Large Loss-of-Coolant Accidents analyzed in Final Safety Analysis Reports are usually covered by Reactor Inlet Header. Reactor Outlet Header and Primary Pump Suction breaks as representative cases. In this study we analyze the total (guillotine) break of an Emergency Core Cooling System (ECCS) pipe located at the ECCS injection point into the Primary Heat Transport System (PHTS). It was expected that thermal-hydraulic behaviors in the PHT and ECC systems are different from those of a Reactor Inlet Header break, having an equivalent break size. The main purpose of this study is to get insights on the differences occurred between the two cases and to assess these differences from the phenomenon behavior point of view. It was also investigated whether the ECCS line break analysis results could be covered by header break analysis results. The study reveals that as the intact loop has almost the same behavior in both analyzed cases. broken loop behavior is different mostly regarding sheath temperature in the critical core pass and pressure decrease in the broken Reactor Inlet Header. Differences are also met in the ECCS behavior and in event sequences timings.

  • PDF

광열변위의 위상곡선을 이용한 금속재료의 열확산계수 측정 (Thermal Diffusivity Measurement for Metal Using Phase Curve of Photothermal Displacement)

  • 이은호;이광재;유재석
    • 대한기계학회논문집B
    • /
    • 제25권1호
    • /
    • pp.47-53
    • /
    • 2001
  • As the technology has developed and new materials have been produced, it is important to measure the thermal diffusivity of material and to predict the heat transfer in the solid subject to thermal processes. This measurement can be done in a non-contact way using photothermal displacenent spectroscopy. In this study, photothermal displacement method was used to measure the thermal diffusivity quantitatively. The specimens used in this study were the pure materials. The Ar-ion laser was used as an energy source and the periodical deformation induced by this pump laser was detected by the He-Ne laser. The magnitude and the phase angle of deformation gradient were measured. The thermal diffusivity was obtained by analyzing the phase angle of deformation gradient. As the result, comparing with the literature value, the thermal diffusivities of materials measured were showed about 2% error.

두 개의 챔버를 갖는 마이크로 버블펌프의 개발 (Development of having double-chamber in micro-bubble pump)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

$Er^{3+}$$Tm^{3+}$이 복합 첨가된 실리카 광섬유의 ASE 광원에 대한 특성 평가 (Characterization of amplified spontaneous emission light source from an $Er^{3+}$/$Tm^{3+}$co-doped silica fiber)

  • Jeong, Hoon;Oh, K.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.96-97
    • /
    • 2000
  • Incoherent broadband optical sources have been applied in various areas such as a light source for optical device characterization, fiber-optic gyroscopes$^{(1)}$ , and spectrum sliced light source in wavelength division multiplexing (WDM) system$^{(2)}$ . To utilize the inherent low loss in silica optical fibers, various types of incoherent light sources are being developed. Among the light sources, the amplified spontaneous emission (ASE) from a rare earth doped fiber has benefits in temperature stability, high output power, low polarization dependence over semiconductor diodes$^{(3)}$ . Recently erbium doped fibers (EDF) have been intensively researched for ASE sources as well as optical amplifiers$^{(4)}$ . The spectrum of ASE from an EDF, however, is limited in the 1520~1560 nm range in conventional configurations. In this letter we described a new broadband ASE source which included both the conventional ASE band of Er$^{3+}$ ion, 1520nm~1560nm and ASE band from Tm$^{3+}$ ions that extends the bandwidth further. For the first time, to the best knowledge of authors, a fiber ASE source based on the energy transfer between Er$^{3+}$ and Tm$^{3+}$ ions in the range of 1460~1550 nm, has been demonstrated using a single 980nm pump laser diode. (omitted)omitted)

  • PDF

저가형 냉각탑 자동 수질 진단 시스템 개발 (Development of a Low-cost Automatic Water Quality Diagnosis System for Cooling Towers)

  • 김정환;박한빈;강태삼;박정근
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.58-65
    • /
    • 2014
  • We developed a low-cost automatic diagnosis system for water quality in cooling towers to measure the concentrations of key ingredients such as $Ca^{2+}$, $Cl^-$, $PO{_4}^{3-}$, and $Fe^{2+}$. $Ca^{2+}$, and $Cl^-$ are the main factors that cause the generation of scale, corrosion, and sludge in water pipes. $PO{_4}^{3-}$ prevents corrosion, sludge and scale by inhibiting the ions (i.e., $Ca^{2+}$, $Cl^-$) from sticking to the pipes. $Fe^{2+}$ is an indicator of pipe corrosion. The proposed system consists of a microprocessor, a specimen container and heater, a precision pump, relays and valves, LED optical sources, and photo detectors. It automatically collects water samples and carries out pretreatment for determining the concentration of each chemical, and then estimates the concentration of each ion using low-cost LED optical sources and detectors. Experimental results showed that the accuracy of the proposed system is sufficiently high for water quality diagnosis and management of cooling towers, demonstrating the possibility of the proposed system's wide usage in real environments.

토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의 (Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model)

  • 이성순;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

방사광 차단용 진공부품의 냉각수 누설 특성 (Characteristics of Water Leakage from Cooling Components in a Storage Ring)

  • 박종도
    • 한국진공학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 포항가속기연구소 저장링에 설치된 방사광 차단용 진공부품에서 냉각수가 누설되었을 때의 진공도 분포, 압력 변화, 잔류 기체의 변화 등을 측정하여 그 특성을 분석하였다. 냉각수 누설 시에 압력 상승은 국부적으로 나타났으며 잔류 기체의 변화 양상은 누설 위치로부터 잔류기체 분석기까지 거리와 이온펌프 및 전자빔의 On/Off에 따라서 크게 달랐으며 특정 기체의 선택적 상승도 나타났다. 냉각수 누설의 발견은 전압변화 측정으로 가능하였으며 잔류기체 분석기로는 물분자를 직접 측정하기보다는 $CH_4$, CO, NO 등 특성 기체의 증가를 분석함으로 누설 여부를 판단할 수 있었다.

ECR-PECVD 장치의 제작과 특성 (Manufacturing and characterization of ECR-PECVD system)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF

Membrane 공정을 이용한 폐수로부터 중금속의 제거 및 기기분석 (Removal of a Heavy Metal from Wastewater using Membrane Process and Instrumental Analysis)

  • 박경애;이승범;김형진;홍인권
    • Elastomers and Composites
    • /
    • 제30권3호
    • /
    • pp.229-234
    • /
    • 1995
  • Membrane process has been applied widely to petroleum chemistry, fine chemistry, polymer, electronics, food, bioprocessing, and wastewater treatment process. Membrane process has advantage that there's no phase change through separation, energy consumption is smaller than other separation processes. And equipment investment and operation cost are inxpensive too. We prepared the silicone rubber membrane and then separated the heavy metal ion from wastewater. Silicone rubber membrane was prepared using a superitical fluid process and heavy metal ions were separated from the chromium nitrate, ferric sulfate, cupric sulfate, nickel sulfate aqueous solution. The pressure difference between top and bottom of separation apparatus was preserved by vacuum pump, and the removal amount of heavy metal at each separation step were analyzed by instrumental analysis, AAS. The surface and pore of silicone rubber membrane was investigated using SEM, and the capability of wastewater treatment using a silicone rubber membrane was proposed as calculated removal rate of heavy metal after comparing removal amount of heavy metal to amount of heavy metal in mother solution by AAS analysis.

  • PDF

Modeling Green-light Fiber Amplifiers for Visible-light Communication Systems

  • Khushik, Muhammad Hanif Ahmed Khan;Jiang, Chun
    • Current Optics and Photonics
    • /
    • 제3권2호
    • /
    • pp.105-110
    • /
    • 2019
  • The visible-light communication (VLC) system is a promising candidate to fulfill the present and future demands for a high-speed, cost-effective, and larger-bandwidth communication system. VLC modulates the visible-light signals from solid-state LEDs to transmit data between transmitter and receiver, but the broadcasting and the line-of-sight propagation nature of visible-light signals make VLC a communication system with a limited operating range. We present a novel architecture to increase the operating range of VLC. In our proposed architecture, we guide the visible-light signals through the fiber and amplify the dissipated signals using visible-light fiber amplifiers (VLFAs), which are the most important and the novel devices needed for the proposed architecture of the VLC. Therefore, we design, analyze, and apply a VLFA to VLC, to overcome the inherent drawbacks of VLC. Numerical results show that under given constant conditions, the VLFA can amplify the signal up to 35.0 dB. We have analyzed the effects of fiber length, active ion concentration, pump power, and input signal power on the gain and the noise figure (NF).