• Title/Summary/Keyword: Ion mobility spectrometry

Search Result 27, Processing Time 0.024 seconds

Amino-β-cyclodextrin Complex Assisted Ionization for Labile Sesamins and their Ion-mobility Separation in ESI Q-TOF MS

  • Sugahara, Kohtaro;Horikawa, Manabu;Yamagaki, Tohru
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.17-20
    • /
    • 2015
  • Sesamin, one of the lignans in sesame seed, was a labile compound in MS and it was reported that the protonated molecule of sesamin decomposed easily in ES ionization process and it cannot be detected (G. Yan, et al., Rapid Commun Mass Spectrom. 2007, 21, 3613-3620). To protect labile compounds, an amino-cyclodextrin (NCyD) was added to the sample to promote the host-guest interaction complex in ESI-MS. As a result, sesamin was ionized as the NCyD-sesamin-NCyD (1:2) complex without undesired decomposition, suggesting that the amino-CyDs assist the ionization of the labile molecules capped with CyDs by host-guest interaction and these compounds were ionized without their decomposition, those are like amino-CyD complex-assisted ionization. The amino-CyD complexes of sesamin and sesamolin were also analyzed by their ion-mobility MS.

Characterization of Volatile Compounds in Donkey Meat by Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) Combined with Chemometrics

  • Mengmeng Li;Mengqi Sun;Wei Ren;Limin Man;Wenqiong Chai;Guiqin Liu;Mingxia Zhu;Changfa Wang
    • Food Science of Animal Resources
    • /
    • v.44 no.1
    • /
    • pp.165-177
    • /
    • 2024
  • Volatile compounds (VOCs) are an important factor affecting meat quality. However, the characteristic VOCs in different parts of donkey meat remain unknown. Accordingly, this study represents a preliminary investigation of VOCs to differentiate between different cuts of donkey meat by using headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) combined with chemometrics analysis. The results showed that the 31 VOCs identified in donkey meat, ketones, alcohols, aldehydes, and esters were the predominant categories. A total of 10 VOCs with relative odor activity values ≥1 were found to be characteristic of donkey meat, including pentanone, hexanal, nonanal, octanal, and 3-methylbutanal. The VOC profiles in different parts of donkey meat were well differentiated using three- and two-dimensional fingerprint maps. Nine differential VOCs that represent potential markers to discriminate different parts of donkey meat were identified by chemometrics analysis. These include 2-butanone, 2-pentanone, and 2-heptanone. Thus, the VOC profiles in donkey meat and specific VOCs in different parts of donkey meat were revealed by HS-GC-IMS combined with chemometrics, whcih provided a basis and method of investigating the characteristic VOCs and quality control of donkey meat.

A Comprehensive Review of Recent Advances in the Enrichment and Mass Spectrometric Analysis of Glycoproteins and Glycopeptides in Complex Biological Matrices

  • Mohamed A. Gab-Allah;Jeongkwon Kim
    • Mass Spectrometry Letters
    • /
    • v.15 no.1
    • /
    • pp.1-25
    • /
    • 2024
  • Protein glycosylation, a highly significant and ubiquitous post-translational modification (PTM) in eukaryotic cells, has attracted considerable research interest due to its pivotal role in a wide array of essential biological processes. Conducting a comprehensive analysis of glycoproteins is imperative for understanding glycoprotein bio-functions and identifying glycosylated biomarkers. However, the complexity and heterogeneity of glycan structures, coupled with the low abundance and poor ionization efficiencies of glycopeptides have all contributed to making the analysis and subsequent identification of glycans and glycopeptides much more challenging than any other biopolymers. Nevertheless, the significant advancements in enrichment techniques, chromatographic separation, and mass spectrometric methodologies represent promising avenues for mitigating these challenges. Numerous substrates and multifunctional materials are being designed for glycopeptide enrichment, proving valuable in glycomics and glycoproteomics. Mass spectrometry (MS) is pivotal for probing protein glycosylation, offering sensitivity and structural insight into glycopeptides and glycans. Additionally, enhanced MS-based glycopeptide characterization employs various separation techniques like liquid chromatography, capillary electrophoresis, and ion mobility. In this review, we highlight recent advances in enrichment methods and MS-based separation techniques for analyzing different types of protein glycosylation. This review also discusses various approaches employed for glycan release that facilitate the investigation of the glycosylation sites of the identified glycoproteins. Furthermore, numerous bioinformatics tools aiding in accurately characterizing glycan and glycopeptides are covered.

Conformational Studies of Gaseous Proteins Using Mass Spectrometry

  • Oh, Han-Bin
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.27-27
    • /
    • 2003
  • Conformations of the +5 to +13 charge state of ubiquitin ions have been studied in the gas phase by an Electron Capture Dissociation (ECD) mass spectrometry (MS) technique. This approach has showed that the conformations of the gaseous ions change from the compact to extended structures as the number of protons on the protein ions increases, consistent with previous collisional cross-section measurements by an ion-mobility MS. However, this observation is in contrast to that of the solution-phase where the unique native structure is usually found. The (un)folding stability and kinetics of these gaseous ions were further investigated experimentally using gradual blackbody-radiation or sudden laser-induced thermal heating, respectively. These studies have provided the evidence that the thermodynamics and kinetics of protein (un)folding in the gas phase are quite different from those of the native aqueous proteins.

  • PDF

A Study on Characteristics of Sampling Flow and Pressure Conditions for Chemical Detection Optimization (화학탐지 최적화를 위한 유동 및 압력 특성 연구)

  • Son, In-Sung;Yoon, Soon-Min;Kim, Hak-Sin;Yuk, Young-Ho;Park, ByeongHwang;Kim, JuHyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.258-264
    • /
    • 2014
  • In terms of chemical detection performance related with chemical material sampling, this investigation shows optimized values, resulted from minimizing loss from air turbulence and other reasons when pressure changes on the basis of sampling flow rate Based on simulations and pressure control of the outside conditions it became possible to obtain ion mobility detection optimum values, and to derive standard pressure conditions that is appropriate for DMS characteristic.

Effects of Oxygen on the Properties of Mg-doped Zinc Tin Oxide Films Prepared by rf Magnetron Sputtering (rf 마그네트론 스퍼터링으로 증착한 Mg-doped Zinc Tin Oxide막의 특성에 미치는 산소의 영향)

  • Park, Ki Cheol;Ma, Tae Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.373-379
    • /
    • 2013
  • Mg-doped zinc tin oxide (ZTO:Mg) thin films were prepared on glasses by rf magnetron sputtering. $O_2$ was introduced into the chamber during the sputtering. The optical properties of the films as a function of oxygen flow rate were studied. The crystal structure, elementary properties, and depth profiles of the films were investigated by X-ray diffraction (XRD), x-ray photoelectron spectroscopy (XPS), and secondary ion mass spectrometry (SIMS), respectively. Bottom-gate transparent thin film transistors were fabricated on $N^+$ Si wafers, and the variation of mobility, threshold voltage etc. with the oxygen flow rate were observed.

Study of PSII-treated PMMA, PHEMA, and PHPMA ; Investigation of Their Surface Stabilities

  • Hyuneui Lim;Lee, Yeonhee;Seunghee Han;Jeonghee Cho;Moojin suh;Kem, Kang-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.204-204
    • /
    • 1999
  • The plasma source ion implantation(PSII) technique which is a method using high negative voltage pulse in plasma system has the potential to change the surface properties of polymer. PSII technique increase the surface free energy by introducing polar functional groups on the surface so that it improves reactivity, hydrophilicity, adhension, biocompatability, etc. However, the mobility of polymer chains enables the modified surface layers to adapt their composition to interfacial force. This hydrophobic recovery interrupts the stability of modified surfaces to keep for the long time. In this study, poly(methyl methacrylate)(PMMA), poly(2-hydroxyethyl methacrylate)(PHEMA), and polu(2-hydroxypropyl methacylate)(PHPMA) for contact lens application, were modified to improve the wettability with PSII technique and were investigated the surface stabilities. Polymer film was prepared with solution casting(3 wt.% solution) and was annealed at 11$0^{\circ}C$ under vacuum oven to remove solvent completely and to eliminate physical ageing. The thickness of the film measured by scanning electron microscopy (SEM) and surface profilometer was about 10${\mu}{\textrm}{m}$. Polymers were treated with different kinds of gases, pulse frequency, pulse with, pulse voltage, and treatment time. Even though PMMA, PHEMA, and PHPMA have similar repeat unit structure, the optimal treatment conditions and the tendency to hydrophobic recovery were different. PHPMA, more hydrophilic polymer than PMMA and PHEMA showd better wettability and stability after mild treatment. Surface tensions were obtained by water and diiodomethane contact angle measurements to monitor the relation between hydrophobic recovery and polymer structure. Different ion species in plasma change the polar component and dispersion component of polymer surface. For better wettability surface, the increase of polar component was a dominant factor. We also characterized modified polymer surfaces using x-ray photoelectron spectroscopy(XPS), secondary ion mass spectrometry(SIMS), Fourier Transform infrared spectroscopy(FT-IR), and SEM.

  • PDF

Properties of CulnSe$_{2}$ thin films selenizing indium/copper layers prepared by D.C. magnetron sputtering (D.C. magnetron sputtering에 의해 indium/copper 층이 selenizing된 $CuInSe_2$막의 특성)

  • Han, Sang-Kyu;Kim, Sun-Jae;Lee, Hyung-Bock;Lee, Byung-Ha;Park, Sung
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.298-305
    • /
    • 1995
  • Copper-indium diselenide, $CuInSe_2$, thin films have been fabricated by selenizing Cu/In stacked layers with different sputtered Cu/(Cu+ln) mole ratios at 450.deg. C for 1hr on alumina substrates. The selenium source was selenium vapor. Microstructure, crystallization, and composition of the selenized $CuInSe_2$ films were examined by using scanning electron microscope, X-ray diffraction, Auger electron spectroscopy, and secondary ion mass spectrometry. Electrical resistivity and hall effects were also measured to investigate the electrical properties. As the sputtered Cu/(Cu+In) mole ratio of In/Cu layer increased, the amounts of void and CuSe phase in the selenized films increased but the composition of $CuInSe_2$ phase was the same regardless of the sputtered mole ratio. Comparing the electrical properties of $CuInSe_2$ thin film before and after the chemical etching, it was seen that the electrical resistivity, carrier concentration, and carrier mobility of the selenized films were affected by the amount of CuSe phase which seemed to increase primarily the hole concentration of the selenized films.

  • PDF

Study on the Electrical Properties of Amorphous HfInZnO TFTs Depending on Sputtering Power (비정질 하프늄인듐징크옥사이드 산화물 반도체의 공정 파워에 따른 트랜지스터의 전기적 특성 연구)

  • Yoo, Dong-Youn;Chong, Eu-Gene;Kim, Do-Hyung;Ju, Byeong-Kwon;Lee, Sang-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.674-677
    • /
    • 2011
  • The dependency of sputtering power on the electrical performances in amorphous HIZO-TFT (hafnium-indium-zinc-oxide thin film transistors) has been investigated. The HIZO channel layers were prepared by using radio frequency (RF) magnetron sputtering method with different sputtering power at room temperature. TOF-SIMS (time of flight secondary ion mass spectrometry) was performed to confirm doping of hafnium atom in IZO film. The field effect mobility (${\mu}FE$) increased and threshold voltage ($V_{th}$) shifted to negative direction with increasing sputtering power. This result can be attributed to the high energy particles knocking-out oxygen atoms. As a result, oxygen vacancies generated in HIZO channel layer with increasing sputtering power resulted in negative shift in Vth and increase in on-current.