• Title/Summary/Keyword: Ion generator

Search Result 97, Processing Time 0.031 seconds

Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma (플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • An ion energy spectrometer which has the $45^{\circ}$ parallel electrostatic deflection plate was designed and constructed for measuring ion temperature in high temperature plasma. The energy calibration and the energy resolution were studied in detail for a hydrogen ion at the $0.24{\sim}1.92\;keV$ energy using electrostatic accelerator with a duoplasmatron ion source. The voltage of the deflection plate was linearly increased for the decreased ion detector position at the constant ion energy and decreased for the increased ion energy at the fixed ion detector position. The inclination of the deflection plate voltage to the ion energy was between 0.92 and 1.61, and linearly decreased for the increased the ion detector position. The measured energy resolution, which is $4.2%\;{\sim}\;11.6%$ in this experiment region, was improved for the increased ion dector position and ion energy. The relative efficiency was increased for the decreased the ion detector position. The ion energy spectrum of the DC plasma in the multi-purpose plasma generator was measured using this equipment. The ion temperature was 203-205 eV at the discharge voltage 320 V, discharge current 1.7 A.

  • PDF

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

Development of A Floating Solar Thermoelectric Generator Using A Dome Shaped Fresnel Lens for Ocean Application

  • Seong-Hoon Kim;Jeung-Sang Go
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_1
    • /
    • pp.1001-1010
    • /
    • 2023
  • To solve the problem that photovoltaic panels can not harvest electrical energy at a cloudy day and night, a floating solar thermoelectric generator (FSTEG, hereafter) is studied. The FSTEG is consisted of a dome shaped Fresnel lens to condense solar energy, a thermoelectric module connected with a heat sink to keep temperature difference, a floating system simulating a wavy ocean and an electrical circuit for energy storage. The dome shaped Fresnel lens was designed to have 29 prisms and its optical performance was evaluated outdoors under natural sunlight. Four thermoelectric modules were electrically connected and its performance was evaluated. The generated energy w as stored in a Li-ion battery by using a DC-DC step-up converter. For the application of ocean environment, the FSTEG was covered by the dome shaped Fresnel lens and sealed to float in a water-filled reservoir. The harvested energy shows a potential and a method that the FSTEG is suitable for the energy generation in the ocean environment.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Starter/Alternator Systems for HEV and Their Control: A Review

  • Boldea, Ion.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.157-169
    • /
    • 2004
  • Motor & generator operation at widely variable speeds is needed in various applications but hybrid and electric vehicle (HEV) stand out today, as quite a few companies are launching this year their mass production of HEVs. The quest for better starter-generators is far from ended, though. The present review paper unfolds a comparative critical evaluation of various starter-generators and their control for HEV. Induction, interior PM synchronous, transverse-flux PM synchronous, switched reluctance, together with claw-pole and biaxial excitation PM synchronous (BEGA) configurations with their control are all considered in system evaluations.

Characteristics of Secondary Electron Emission for Electron Beam Extraction (전자빔 인출을 위한 2차전자방출 특성 연구)

  • Woo, Sung-Hun;Lee, Hong-Sik;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.204-206
    • /
    • 2003
  • Electron beam generator of cold cathode type has been developed for industrial application, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The characteristics of secondary electron emission are studied by comparing total cathode current with ion current.

  • PDF

The Development of Hot Carrier Immunity Device in NMOSFET's (NMOSFET에서 핫-캐리어 내성의 소자 개발)

  • ;;;;Fadul Ahmed Mohammed
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.365-368
    • /
    • 2002
  • WSW(Wrap Side Wall) is proposed to decrease junction electric field in this paper. WSW process is fabricated after first gate etch, followed NMI ion implantation and deposition & etch nitride layer New WSW structure has buffer layer to decrease electric field. Also we compared the hot carrier characteristics of WSW and conventional. Also, we design a test pattern including pulse generator, level shifter and frequency divider, so that we can evaluate AC hot carrier degradation on-chip.

  • PDF

Development of the wind generation output stabilization with Lithium-ion battery (리티움-이온 배터리를 이용한 풍력발전의 출력안정화 시스템 개발)

  • Oh, Seung-Jin;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.178-179
    • /
    • 2010
  • This paper presents a simulation model and analysis of grid-tied wind turbine generator with batteries using the PSCAD/EMTDC software. The modeled system is consist of two inverters and one bidirectional DC/DC converter. These inverter are to capture the maximum active power under varying wind conditions and to keep the DC-Link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load. Aerodynamic models are applied for a wind turbine blade simulator.

  • PDF

Determination of Installation Point for Negative-Ion Generator in Passenger Room using by CFD (CFD를 이용한 객실 내 음이온 발생기 설치위치 결정)

  • 이주열;박덕신;정우성;김동술
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.344-345
    • /
    • 2002
  • 철도차량은 고속으로 운행되므로 승객의 안전을 위해 객실 창문의 개폐가 불가능하게 되어 있다. 객실은 전체가 밀폐되어 자연환기가 아닌 공조시스템만으로 공기 질이 조절 가능하다. 철도는 주로 장거리 승객이 이용하며, 다수의 승객은 한정된 공간에서 장시간 체류하면서 객실 내에서 발생되거나 외부에서 유입되는 각종 대기오염물질에 노출되고 있다. (중략)

  • PDF

Mesurement of Collectively Accelerated Argon Ion Energy (집단 가속된 아르곤 이온의 에너지 측정)

  • 박인호;최은하
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.4
    • /
    • pp.425-430
    • /
    • 1995
  • 본 연구에서는 Marx Generator와 펄스 형성라인을 결합시켜 만든 VEBA(Versatile Electron Beam Accelerator)장치를 사용하여 아르곤 이온의 에너지를 식각 추적 방법을 써서 측정하였다. 이 장치에서 240kV, 30kA, 60ns의 전자빔이 발생되었다. 이 전자빔이 이극관을 통과하면서 이 때 주입된 아르곤 기체가 이온화되어 아르곤 이온이 얻어진다. 이렇게 형성된 이온은 가상적 음극에 의해 진공 전파관 속으로 가속되고 이를 전자빔과 분리한 후 알루미늄 박막으로 만든 식각 추적판을 때리도록 장치하였다. 이때 아르곤 이온이 뚫고 들어간 알루미늄 박막의 수로부터 이온의 에너지를 구하였다. 이렇게 얻어진 실험값은 이론값과 잘 일치하였다.

  • PDF