보존처리용 세척제에 대한 토기의 이온용출 특성연구 (A Study on Ion Extraction Characteristics of Ceramics by Cleaning Agents)

  • 박대우;강현미;남병직;장성윤;함철희
    • 보존과학연구
    • /
    • 통권31호
    • /
    • pp.43-57
    • /
    • 2010
  • This study intends to provide quantitative data about the extraction characteristics of major elements of earthenware by executing soaking test of cleaning agents. It aims at providing basic data for the stability assessment when applying the cleaning agents for conserving earthenware. The data will be extracted from the analysis of co-relationship between the physical characteristics and the ion extraction characteristics. XRD analysis displayed that AT-1, AT-2 and AT-3 which did not generate mullite were fired at lower than 1,000 whereas AT-3 and AT-5 that included mullite were higher than 1,000. The degree of absorption was AT-4 > AT-2 > AT-1 > AT-3 > AT-5 in order and the correlation between the degree of absorption and firing temperature of earthenware displayed a positive correlation. Extraction amount of oxalic acid which was used for the removing iron oxide was AT-1 > AT-2 AT-4 > AT-3 > AT-5 in order. and the ion extraction data displayed that there is a positive correlation with absorption level. However AT-1 and AT-2 which were fired at lower temperature showed that there was no correlation between the ion extraction characteristics and absorption level. Ion extraction of citric acid produced little amount compared with the one of oxalic acid, yet it caused less damage to earthenware than oxalic acid when it applied. The result of ion extraction level in the absorption test displayed that Fe had higher level than in Si, Al from the test for both oxalic acid and citric acid. Based on the regression analysis of the data from the previous studies, the physical characteristics of the earthenware and ion extraction level, further studies will be conducted on the predicting technique on the extraction characteristics of major elements of earthenware samples for the conservation in future.

  • PDF

Duoplasmatron 이온원에서의 $He^+$ 이온빔 인출에 관한 연구 (A Study on $He^+$ Ion Beam Extraction in the Duoplasmatron Ion Source)

  • Myong-Seop KIM;Hae-iLL BAK
    • Nuclear Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.438-443
    • /
    • 1991
  • 각확산도가 작은 $He^+$ 이온빔 인출전류를 최대로 얻기 위하여 Duoplasmatron 이온원의 동작특성을 조사하였다. 이온원의 기체압력, 아크전류. 전자석 전류, 인출전압등을 변화시키면서 인출되는 $He^+$ 이온빔 전류의 변화를 관찰하였다. 열음극으로는 Ni망위에 BaO와 SrO의 혼합물을 코팅한 산화물 필라멘트를 사용하였으며, 그것의 평균수명은 약 100시간이었다. 인출전류는 아크전류에 선형적으로 비례했다 이온원 전자석전류를 증가시킴에 따라 인출전류는 증가하였지만 빔의 각확산도가 커졌다. 최대의 인출전류는 0.084 Torr의 이온원 압력에서 얻어졌다. 인출전류는 이론에서와 마찬가지로 인출전압의 3/2승에 비례하였다. 5.72 kV의 인출전압에서는 최적인출조건하에서 50 $\mu$A의 인출전류가 얻어졌다.

  • PDF

Picric Acid에 의한 지방족 아민류와 4급 암모늄 염류의 이온쌍 추출 (Ion Pair Extraction of Aliphatic Amines and Quaternary Ammonium Salts by Picric Acid)

  • 김박광;이종숙;장성기;나운용;옥치환
    • 약학회지
    • /
    • 제35권3호
    • /
    • pp.182-189
    • /
    • 1991
  • Systematic study on the extraction of ion pair by the use of picric acid (PCA) as an ion pair forming reagent to the aliphatic amines has not be done by spectrophotometric method. The extraction of ion pair by the use of PCA and 23 kinds of the aliphatic amines was examined. The procedure is as follows; Elving's buffer solution (pH 1.3~10, ionic strength 0.5) each amine solution, and PCA solution were taken into a test tube. The mixture was shaken mechanically with chlorform. The organic phase was filtered through a filter paper to remove water droplets. The absorbance was examined at $\lambda_{max}$ against a reagent blank. Primary and secondary whose carbon number were more than 7 or 6, respectively, are extractable as ion pairs with PCA, while tertiary amines and quaternary ammonium salts are also extractable without the correlation of carbon number. It was considered that the ion pair extraction of primary and secondary amines was affected by the number of carbon of amines, but its extraction of tertiary amines or quaternary ammonium salts was affected by kind of aliphatic amines rather than pKa values or carbon number of amines.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

개방형 왕복 다공판 추출탑을 이용한 액막법에 의한 폐수중 Cr(Vl)의 추출 (Extraction of Chromium (Vl) Son in Waste Water through the Liquid Surfactant Membrane with Open-Type Perforated Reciprocating-Plate Column)

  • 우인성;강현춘;안형환
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.44-50
    • /
    • 1993
  • The objective of this study was to investigate the extraction of chromium(Vl) ion in waste water through the liquid surfactant membrane with open-type Perforated Reciprocating-Plate Column. Extraction experiments were conducted to measure the effect of flow characteristics of continuous and dispersed phase and stroke velocity, sodium hydroxide concentraction in internal aqueous phase, sulfuric acid concentraction in outer phase, and residence time distribution and measured extraction velocity. The result of experiments showed that extraction velocity of chromium ion was maximum when stroke velocity was 180 1/min and dispersion phase velocity was 30m11min, continuous phase velocity was 20m1/min. Extraction velocity of chromium ion increased with increasing difference of hydrogen ion concentraction of dispersion and continuous phase and column stage decreased.

  • PDF

지지막을 이용하는 액막 추출기 내에서 아연 이온의 이동 (Transport of Zinc Ion in a Contained Liquid Membrane Permeator with Two Micro-Porous Films)

  • 주창식;이석희;이민규;홍성수;하홍두;정석기
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.159-164
    • /
    • 2000
  • For the purpose of development of a liquid membrane permeator which separates metal ions from aqueous solutions continuously and effectively, a continuous membrane permeator with the membrane solution trapped between extraction and stripping phases by two micro-porous hydrophilic films was manufactured. Experimental researches on the separation of zinc ion from aqueous solutions were performed in the liquid membrane permeator with 30 vol % D2EHPA solution in kerosine as liquid membrane. As results, the liquid membrane permeator separates zinc ion from aqueous solutions continuously and effectively in the wide range of operating conditions. A simple mass transfer rate model using equilibrium constant of the extraction reaction for the system used were proposed, and the model was compared with experimental results of separation of zinc ion in the permeator. And the effects of operating factors, such as space time, pH of extraction solution, extraction temperature, on the separation rate of zinc ion in the permeator were experimentally examined.

  • PDF

A compact mass spectrometer for plasma ion species analysis

  • 김광훈;;최영욱;이홍식;임근희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.185-185
    • /
    • 2000
  • 플라즈마 연구 및 응용에서 플라즈마를 구성하는 이온에 대한 정보를 얻는 것은 중요하다. 특히 플라즈마 진단, 박막 증착, 플라즈마 코팅, 플라즈마 이온주입 등과 같은 플라즈마 프로세싱에서 이온들의 종류 구성비율 및 분포는 매우 중요하다. 질량분석기는 대개 큰 규모로 복잡하고 값비싼 경향이 있다. 플라즈마 교란을 최소화하면서 충분한 질량분해능을 갖고 국소적으로 이온들을 분석할 수 있는 간단하고 작은 규모의 값싼 질량분석기가 필요하다. 본 연구에서는 플라즈마 내에 존재하는 이온을 분석하기 위하여 간단하고 작은 규모의 값싼 프라즈마 이온 질량분석기를 설계, 제작하였다. 이온 질량분석기는 ion extraction part, double focusing sector magnet, ion collector로 구성되어 있다. 플라즈마에 잠기는 ion extraction part의 외부 전극에 Al2O3를 코팅하여 플라즈마 교란을 최소화하였다. 이온들의 공간적 분포를 측정하기 쉽게 하기 위하여 ion extraction part를 이동하여도 질량여과기를 통과한 후에 접속되는 초점의 위치가 Faraday ion collector 에 고정되도록 ion optical system을 설계하였다. Extracting electrode에 의하여 가속된 이온들이 sector magnet에 들어갈 때 평행이 되게 하기 위하여 여러 개의 미세구조를 갖는 Mo grids를 사용하고 immersion lens를 넣어서 이온 광학 시스템을 구성하였다. extraction electrode와 sector magnet 사이에 보조 electrode를 하나 더 넣어서 extracting electrode와 보조 electrode 사이에 immersion lens를 만들었다. 질량여과기로는 permanent magnet sector와 time-varying electrical field를 결합하여 사용하였다. Extracting electrode에 1kV 정도의 전압을 인가하여 이온들을 가속시키고 sector magnet에 톱니파 형태의 전압을 인가하여 mass spectrum을 얻었다. 이온 질량분석기를 플라즈마 장치에 적용하여 질량분해능 등의 특성을 연구하였다. Hot cathode discharge와 inductively coupled RF discharge에서 발생된 질소 플라즈마를 구성하는 이온들의 종류와 그 구성비율을 연구하였다.

  • PDF

유도결합형 플라즈마 소스를 이용한 집속 이온빔용 가스 이온원 개발 (Development of Inductively Coupled Plasma Gas Ion Source for Focused Ion Beam)

  • 이승훈;김도근;강재욱;김태곤;민병권;김종국
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.19-23
    • /
    • 2011
  • Recently, focused ion beam (FIB) applications have been investigated for the modification of VLSI circuit, the MEMS processing, and the localized ion doping, A multi aperture FIB system has been introduced as the demands of FIB applications for high speed and large area processing increase. A liquid metal ion source has problems, a large angular divergence and a metal contamination into a substrate. In this study, a gas ion source was introduced to replace a liquid metal ion source. The gas ion source generated inductively coupled plasma (ICP) in a quartz tube (diameter: 45 mm). Ar gas fed into the quartz was ionized by a 2 turned radio frequency antenna. The Ar ions were extracted by 2 extraction grids. The maximum extraction voltage was 10 kV. A numerical simulation was used to optimize the design of extraction grids and to predict an ion trajectory. As a result, the maximum ion current density was 38 $mA/cm^2$ and the spread of ion energy was 1.6 % for the extraction voltage.

PCC 제조를 위한 칼슘이온 추출 조건에 관한 연구 (A Study on the Calcium Ion Extraction for PCC Production)

  • 이예환;이상현;황인혁;최성열;이상문;김성수
    • 공업화학
    • /
    • 제29권1호
    • /
    • pp.43-48
    • /
    • 2018
  • 본 연구에서는 PCC (precipitated calcium carbonate) 제조에 있어 칼슘이온 추출 최적화를 위하여 추출 용제, 용제의 농도, 추출원의 투입량, 전처리 공정 등 다양한 추출 조건에 따른 실험을 수행하였다. 칼슘추출원으로 CaO를 사용하였으며, 칼슘이온의 추출량과 CaO의 입자크기를 확인하기 위하여 ICP와 SEM 분석을 수행하였다. 그 결과 2 M의 hydrochloric acid를 용제로 사용한 경우 100%의 칼슘이온이 추출되었으며, 추출원의 최적 투입량은 6 g으로 확인하였다. 반면 반응시간, 반응온도, 입자 분쇄 및 열처리 공정은 칼슘이온 추출량에 큰 영향이 없음을 확인하였다.

지지막을 이용한 액막 추출기에 의한 합성해수 중의 $Sr^{2+}$ 이온 분리 (Separation of $Sr^{2+}$ Ion from Seawater by Liquid Membrane Permeator with Two Micro-Porous Films)

  • 주창식;이회근;정갑섭
    • 한국환경과학회지
    • /
    • 제9권6호
    • /
    • pp.517-522
    • /
    • 2000
  • Separation of strontium ion from synthetic seawater in the contained liquid membrane permeator with two micro-porous films was performed. The permeator consisted of a liquid membrane and two cells for aqueous solutions. The liquid membrane consisted of $D_2EHPA(di-2-ethylhexy1-phosphoric acid)$ and DCH18C6 (dicyclohexano-18-crown-6),diluted to 30 vol% with kerosine and was trapped between two micro-porous hydrophilic films. This liquid membrane separated two aqueous solutions, one of which was synthetic seawater and the other of which was the stripping solutions consisting of 1mol/L $H_2SO_4$ solution. The effects of various operating parameters on the extraction rate and equilibrium extraction ratio of strontium ion from synthetic seawater were experimentally examined. The addition of DCH18C6 to the $D_2EHPA$ solution caused synergy effect on the extraction of strontium ion. The permeator extracted strontium ion from synthetic seawater effectively with high membrane life time.

  • PDF