• Title/Summary/Keyword: Ion exchanger resin

Search Result 29, Processing Time 0.018 seconds

Synthesis of New Triazacrown Ion Exchanger and Its Ion Exchange Characteristics (새로운 트리아자크라운 이온교환체의 합성과 그의 이온교환 특성)

  • Kim, Dong Won;Chung, Yong Soon;Kim, Chang Suk;Choi, Ki Young;Lee, Yong Ill;Hong, Choon Pyo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.5
    • /
    • pp.371-378
    • /
    • 1995
  • The triazacrown compound, 1,7-dioxa-4,10,13-triazacyclopentadecane trihydrobromide salt (Na3O2-3HBr) was synthesized. And this compound was used to synthesize the new ion exchanger, which combined with Merrifield peptide resin. This new ion exchanger had a capacity of 3.2 meq/g dry resin. And the distribution coefficients of alkali and alkaline earth metal ions on this ion exchanger in the various concentrations of hydrochloric acid were determined. The ion exchange behaviors of alkali and alkaline earth metal ions in the various hydrochloric acid concentrations are, also, discussed.

  • PDF

Adsorption Properties of Nickel ion from Plating Rinse Water Using Hybrid Sulfonated Bead and Fibrous Ion Exchanger (설폰산형 비드와 섬유 혼성체를 이용한 도금수세수 중의 니켈 흡착 특성)

  • 황택성;조상연
    • Polymer(Korea)
    • /
    • v.27 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • In this study, we have investigated the preparation of mixed bead and fiber type hybrid ion-exchanger for recovering nickel ion from plating rinse water. There was little dependence of adsorption capacity for nickel ion on the mixing ratio of resin type and fiber type of ion exchangers. However, it increased with increasing the resin content in the mixed bed. It was shown that the data Langmuir and Freundlich's adsorption isotherm model were well fitted to the linear. Affinity between the functional groups in the ion exchanger and nickel ion in the process was confirmed. The pressure drop decreased with increasing the number of stage in the multistage bed, but it increased with increasing the resin content in the mixing bed. The initial breakthrough time in the multistage bed was short due to the increase of number of stage in the continuous process. It was found that the final breakthrough time of the multistage bed was little changed. The breakthrough time decreased with increasing the amount of fibrous ion exchanger in the mixed bed. The maximum adsorption capacities of the mixed and multistage beds were 2.51 meq/g and 2.69 meq/g, respectively. The desorption time for the nickel ion with $1N H_2SO_4$ solution was lower than 10 minutes and the yield of desorption was greater than 98 percent.

Preparation of Coated-Wire Nitrate Ion Selective Electrode and its Application for Environmental Analysis (질산이온 선택성 피복선 전극의 제작 및 환경분석에의 응용)

  • 李龍根;金昌圭;朴廷泰;金京燮;黃圭子
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.99-107
    • /
    • 1985
  • A coated wire ion selective electrode for nitrate (nitrate-CWE_ was constructed using epoxy resin, ion exchanger and plasticizer as a polymer membrane. It's stility, the composition of a polymer membrane, the response characteristics, the selectivity were examined and applied to the environmental analysis. The nitrate-CWE was prepared using a copper wire, wihch was coated with epoxy resin being incorporated with the nitrate ion exchanger and plasticizer. The best composition of the polymer membrane for the nitrate-CWE was obtained by mixing epoxy resin, ion exchanger and plasticizer in the ratio of 2:1:0.4. The potential (56.3$\pm$0.5 mV) of stick form nitrate-CWE in this composition was close to that (59.2 mV) of Nernstian response. The detection limit for nitrate ion were found to the about $6 \times 10^{-5}M$ and the useful pH was 2.5 $\sim$ 10.3. Furthermore, the selectivity of iodide and perchrorate for the nitrage-CWE was also much improved compared with that for a liquid membrane nitrate electrode. The nitrate-CWE was used to determind $NO_x$ in stack gas. The results were in good agreement with those obtained either by electrode method or by the improved NEDA method within a relative error of 4.0%.

  • PDF

Selective Adsorption Properties of Nitrate ion in Sulfate and Nitrate Solution by Bead and Fibrous Hybrid Ion Exchange Bed (비드와 섬유 혼성이온교환 베드를 이용한 황산이온과 질산이온 혼합용액에서 질산이온의 선택 흡착 특성)

  • 황택성;박명규
    • Polymer(Korea)
    • /
    • v.27 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • In this study, we have investigated the adsorption properties for nitrate ion in ground water using mixed resin type hybrid ion exchange (HIXF) and fiber type ion exchanger. Their swelling ratio (4.45 g/g) and ion exchange capacities (2.45 meq/g) were higer than the swelling ratio of IEC and IXF. Adsorption yield increased for nitrate $NO_3^-$ and sulfate $SO_4^{2-}$ ions were optimal at the concentration ratios of nitrate and sulfate below 1.0 and the adsorption yields were 100% and 20%, respectively. On the other hand it was shown that the degree of adsorpted for nitrate to pH 3, but it was little changed in the other pH range. We found that the selective adsorption capacity for nitrate was the optimal the mixing ratios of resin and fibrous ion exchanger of below 0.5.

Enrichment of Lithium Isotope by Novel Ion Exchanger Containing Azacrown Ether as Anchor Group (앵커 그룹으로서 아자크라운 에테르를 포함한 새로운 이온교환체에 의한 리튬 동위원소의 농축)

  • Kim, Dong Won;Lee, Nam-Soo;Jeong, Young Kyu;Ryu, Haiil;Kim, Chang Suk;Kim, Bong Gyun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.231-234
    • /
    • 1998
  • Separation factor for $^6Li$ and $^7Li$ has been determined using ion exchange resin having 1,7,13-trioxa-4,10,16-triazacyclooctadecane ($N_3O_3$) as an anchor group. The ion exchange capacity of the $N_3O_3$ ion exchanger was 2.0 meq/g dry resin. The lighter isotope, $^6Li$, is concentrated in the fluid phase, while the heavier isotope, $^7Li$, is enriched in the resin phase. By column chromatography [0.3 cm(I.D)${\times}$30 cm (height)] using 3.0 M ammonium chloride solution as an eluent, single separation factor, ${\alpha}$, 1.018, i.e. $(^7Li/^6Li)_{resin}/(^7Li/^6Li)_{fluid}$ was obtained by the Glueckauf theory from the elution curve and isotope ratios.

  • PDF

Construction of Carbon Paste Coated Wire Ion-Selective Electrode for Chloride and Its Application to Environmental Water Analysis

  • Yong-Kyun Lee;Soo Kil Rhim;Kyu-Ja Whang
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.485-488
    • /
    • 1989
  • A carbon paste coated-wire ion-selective electrode for chloride (carbon chloride-CWE) was constructed using epoxy resin, ion-exchanger and carbon powder as a polymer membrane. Its utility, the composition of a polymer membrane, the response characteristics, and the selectivity were examined and applied to the environmental water analysis. The carbon chloride-CWE was prepared using a silver wire, which was covered with silver chloride and then coated with epoxy resin into which chloride ion-exchanger and carbon powder were previously incorporated in advance. The response of the carbon chloride-CWE was Nernstian for $1.0{\times}10^{-2}-2{\times}10^{-5}$ M chloride and the useful pH range from $10^{-2} M Cl- to 10^{-4} M Cl^-$ was 3.0-9.0. Furthermore, the selectivity of chloride over iodide, bromide, and cyanide was much improved compared with those for a solid state epoxy body chloride electrode and a liquid membrane chloride electrode. The carbon chloride-CWE was applied to determine Cl^-$ in tap and ground water. The obtained results were in good agreement with those by the established methods such as spectrophotometric or other chloride-selective electrode methods.

Enrichment of Magnesium Isotopes by Monoazacrown Bonded Merrifield Peptide Resin.

  • Kim, Dong Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.6
    • /
    • pp.570-574
    • /
    • 2001
  • Magnesium isotope separation was investigated by chemical ion exchange with the 1-aza-12-crown-4 bonded Merrifield peptide resin using an elution chromatographic technique. The capacity of the novel azacrown ion exchanger was 1.0 meq/g dry resin. The heavier isotopes of magnesium were enriched in the resin phase, while the lighter isotopes were enriched in the solution phase. The single stage separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assys. The separation factors of $^{24}Mg^{2+}$-$^{25}Mg^{2+}$, $^{24}Mg^{2+}$-$^{26}Mg^{2+}$, and $^{25}Mg^{2+}$-$^{26}Mg^{2+}$ were 1.008, 1.019, and 1.006, respectively.

Separation Characteristics of Alkali and Alkaline Earth Metal Ions Using Novel HDBPDA Ion Exchanger (새로운 HDBPDA 이온교환체를 사용한 알칼리 및 알칼리 토금속 이온들의 분리특성)

  • Kim, Dong Won;Kim, Chang Suk;Choi, Ki Young;Jeon, Young Shin;Hong, Choon Pyo
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.471-477
    • /
    • 1993
  • The novel macrocylic ligand {(4, 5):(13, 14)-dibenzo-6, 9, 12-trioxa-3, 15, 21, -triazabicyclo [15. 3. 1]heneicosa-(1, 17, 19)(18, 20, 21) triene: HDBPDA} was synthesized, and protonable constants of the ligand and the complex stability constants with alkali metals alkaline earth metals were determined. We evaluated the resolution factor(${\Delta}$) from equation that inducing from stability constants(pK). Also, this ligand was grafted on chloromethylated styrene-divinyl benzene(Merrifield resin) for HDBPDA, ion exchanger. Alkali and alkaline earth metal ions were separated using water by the column chromatography with this ion exchanger. Selectivity(${\alpha}$) and resolution(Rs) of alkali and alkaline earth metal ions were measured from the elution curves chromatogram. The selectivity and resolution values of the various ions calculated from the elution curves were compared with those abtained from pK values. The results were in a good agreement between tow methods. Ion exchange capacity of the resin were determined using the alkali and alkaline earth metal ions and pH dependence of capacity was also discussed.

  • PDF

Synthesis of High Loading PONF-g-GMA Anion Exchange Fiber Containing Ion Exchange Resin and Their Adsorption Properties of Vanadium (이온교환 수지를 함유한 PONF-g-GMA High Loading 음이온교환 섬유의 합성 및 바나듐 흡착 특성)

  • Baek, Ki-Wan;Park, Seung-Wook;Nho, Young-Chang;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.315-321
    • /
    • 2007
  • Aminated PONF-9-GMA ion exchange fabrics were synthesized by radiation induced graft copolymerization. Hybrid ion exchange fabrics combined with aminated PONF-g-GMA fabrics and anionic ion exchange resin were also fabricated by hot melt adhesion method and then their adsorption properties were investigated. Ion exchange capacity of the hybrid ion exchange fabrics was higher than ion exchange fabric and was lower than bead resin. The maximum value was 4.18 meq/g. Adsorption breakthrough time for vanadium of the hybrid ion exchange fabric was 550 min, which was faster than bead resin but slower than fibrous ion exchanger. The Breakthrough time of the hybrid ion exchange fabrics gets longer with increasing pH. The initial breakthrough time occurred around 400 min with increasing vanadium concentration.

Industrial Waters of Taegu City and on the Objection of Iron for Water Softening (大邱市의 工業用水와 鐵의 軟化障害에 關하여)

  • Lee, Dae-Soo;Hong, Soon-Yung
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.117-121
    • /
    • 1962
  • The waters throughout Taegu area for 87 points were analysed and according to the analytical data, following unfavorable characteristics for industrial uses were given: (1)Shows strong hardness, (2)Has high ratio of ignition residue to evaporation residue, (3) pH value is over 7, (4) Contains considerable quntities of iron.And then investigated the exchange rate and regeneration level of iron ion using cation exchange resin, Lewatit KS.When the hard water containing 2.2 ppm of iron with 18.4 ppm of calcium and 6.2 ppm of magnesium was passed through the ion exchange resin under $3cc/cm^2/min$ in exhaustant flow rate, exchange rate of iron reached to 42% after 300 hours flow. The exchange efficiency shows abrupt decreasing in initial stage of flow up to 100 hours flow. The exchanger which contains iron was regenerated with 10% sodium hydroxide aqua solution under SV (space velocity) 4. By this method, 57% of iron was eliminated from exchanger while calcium and magnesium are removed as much as 85% and 87% respectively.

  • PDF