• Title/Summary/Keyword: Ion concentration and type

Search Result 287, Processing Time 0.027 seconds

A Study on Secondary Defects in Silicon after 2-step Annealing of the High Energy $^{75}AS^+$ Ion Implanted Silicon (고에너지비소 이온 주입후 2단계 열처리시 2차결함에 대한 연구)

  • 윤상현;곽계달
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.796-803
    • /
    • 1998
  • Intrinsic and proximity gettering are popular processes to get higher cumulative production yield and usually adopt multi-step annealing and high energy ion implantation, respectively. In order to test the combined processed of these, high energy \ulcornerAs\ulcorner ion implantation and 2-step annealing process were adopted. After the ion implantation followed by 2-step annealing, the wafers were cleaved and etched with Wright etchant. The morphology of cross section on samples was inspected by FESEM. The concentration profile of As was measured by SRP. The location and type of secondary defects inspected by HRTEM were dependent on the 1st annealing temperatures. That is, a line of dislocation located at $1.5mutextrm{m}$ apart from the surface at $600^{\circ}C$ lst annealing was changed to some dislocation lines or loops nearby the surface at 100$0^{\circ}C$. The density of dislocation line was reduced but the size of the defects was enlarged as the temperature increased.

  • PDF

A Clinical Study of Changes in Serum Potassium Ion Concentration Before and After Extracorporeal Circulation with Heart-Lung Machine (개심술시 체외순환에 의한 혈청 POTASSIUM 변동에 관한 연구)

  • 고태환
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.854-863
    • /
    • 1990
  • Since the open heart surgery was performed, various kinds of problem concerning the extracorporeal circulation[EGG] have been known. The author investigated the changes of serum potassium ion before and after ECC among the 102 patients including 63 adults and 39 children who underwent open heart surgery from April 19S6 to February 1990 in Chung-Ang University Hospital. The mean values of potassium ion before and after ECC were analyzed according to the influencing factors such as priming solution, aortic cross clamping time, the underlying disease, the type of oxygenator and the amount of cardioplegic solution. The results were as follows: l. In the aspect of congenital and acquired heart disease groups, the mean values of serum potassium ion[Mean\ulcornerS.D.] before and after ECC revealed a significant change only in the acquired heart disease group[congenital; 3.87$\pm$0.48mEq /L vs. 4.05$\pm$0.73mEq /L, P>0.05, acquired: 4.40 $\pm$0.98mEq /L vs. 4.11$\pm$0.52mEq /L, P<0.05]. Between the two groups, the changes of the mean values of serum potassium ion before and after ECC were significant[P<0.05]. But all values were within normal limits. 2. In the aspect of the aortic cross clamping time[ACCT], in the groups of less or more than 120 minutes, the mean values of serum potassium ion before and after ECC revealed no significant change[less than 120 min; 3.97+-0.64mEq /L vs. 3.99+0.67mEq /L, P>0.05, more than 120 min; 4.34+0.82mEq /L vs. 4.27+0.62mEq /L, P>0.05], and The changes of mean values of serum potassium ion between the two groups were not significant[P>0.05]. 3. In both membrane and bubble oxygenator groups, the mean values of serum potassium ion before and after ECC did not reveal a significant difference respectively [membrane; 4.74 +1.40mEq /L vs. 4.28+0.3lmEq /L, P>0.05, bubble; 4.02 +0.60mEq /L vs. 4.05 L0.68mEq/L, P>0.05], and no differences between the membrane and bubble oxygenator groups[P >0.05]. 4. In the groups of membrane and bubble oxygenator in the cases of ACCT more than 120 minutes, the mean values of serum potassium ion before and after ECC did not reveal a significant difference respectively[membrane; 4.36$\pm$0.85mEq /L vs. 4.37$\pm$0.26mEq /L, P>0.05, bubble; 4.30 $\pm$0.80mEq/L vs. 4.23$\pm$0.67mEq/L, P>0.05], and no differences between the two groups[P>0.05]. 5. In spite of increased amount of cold potassium cardioplegic solution, the mean values of serum potassium ion before ECC were similar to those of serum potassium ion after ECC[less than 20ml /kg

  • PDF

The Formation of Nitride and Enhancement of Mechanical Properties of Al Alloy by Nitrogen Implantation (Al합금에서 질소이온주입에 의한 질화물 형성과 기계적 특성 향상)

  • Jeong, Jae-Pil;Lee, Jae-Sang;Kim, Kye-Ryung;Choi, Byung-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • The aluminum nitride(AlN) layer on Al7075 substrate has been formed through nitrogen ion implantation process. The implantation process was performed under the conditions : 100 keV energy, total ion dose up to $2{\times}10^{18}\;ions/cm^2$. XRD analysis showed that aluminum nitride layers were formed by nitrogen implantation. The formation of Aluminum nitride enhanced surface hardness up to 265HK(0.02 N) from 150HK(0.02 N) for the unimplanted specimen. Micro-Knoop hardness test showed that wear resistance was improved about 2 times for nitrogen implanted specimens above $5\;{\times}\;10^{17}\;ions/cm^2$. The friction coefficient was measured by Ball-on-disc type wear tester and was decreased to 1/3 with increasing total nitrogen ion dose up to $1\;{\times}\;10^{18}ions/cm^2$. The enhancement of mechanical properties was observed to be closely associated with AlN formation. AES analysis showed that the maximum concentration of nitrogen increased as ion dose increased until $5\;{\times}\;10^{17}\;ions/cm^2$.

Influence of Carbonation and Freezing-thawing on the Chloride Diffusion in Concrete (탄산화 및 동결융해 현상이 콘크리트 중의 염소이온 확산에 미치는 영향 연구)

  • Kim, Dong-Baek;Kwon, Ki-Jun;Jung, Sang-Hwa;Bok, Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.57-64
    • /
    • 2007
  • Recently, the corrosion of concrete structures has received great attention related with the deterioration of sea-side structures, such as new airport, bridges, and nuclear power plants. In this regards, many studies have been done on the chloride attack in concrete structures. However, those studies were confined mostly to the single deterioration due to chloride only, although actual environment is rather of combined type. The purpose of the present study is, therefore, to explore the influences of carbonation and freezing-thawing action to chloride attack in concrete structures. The test results indicate that the chloride penetration is more pronounced than the case of single chloride attack when the carbonation process is combined with the chloride attack. It is supposed that the chloride ion concentration of carbonation region is higher than the sound region because of the separation of fixed salts. Though the use of fly ash pronounces the chloride ion concentration in surface, amounts of chloride ion penetration into deep region decreases with the use of fly ash. The small reduction of relative dynamic elastic modulus induced from freezing-thawing increases the chloride ion penetration depths much. The present study allows more realistic assessment of durability for such concrete structures which are subjected to combined attacks of both chlorides and carbonation or freezing-thawing but the future studies for combined environment will assure the precise assessment.

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (I). Continuous-Automated Determination of Nitrite Ion Using Tubular PVC Membrane Type of pH Electrode (용해기체 분석용 기체 감응막 이온선택성 전극 (제 1 보). 관형 PVC 막 pH 전극을 이용한 아질산이온의 연속·자동화 정량)

  • Heung Lark Lee;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.388-398
    • /
    • 1989
  • A continuous-automated method for the determination of nitrite ion using gas-sensing membrane electrode was developed. The pH electrode of tubular PVC membrane type was used as a detector of this system. The slope of linear response of the electrode measured at optimum conditions for the continuous-automated determination of nitrite ion was 63.5 mV/decade. The concentration range of linear response and detection limit were 2.5 ${\times}10^{-4}{\sim}\;7.5{\times}10^{-2}$M and $8.0{\times}10^{-5}$M, respectively. This detection system was not only less interfering to acidic gas species than other methods but also less time consumable for determination.

  • PDF

A Dissolved Oxygen Measurement System Using FET-type Dissolved Oxygen Sensor Array (FET형 용존산소 센서 어레이 측정시스템)

  • Jeong, H.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.259-265
    • /
    • 2001
  • FET-type dissolved oxygen sensor has the Pt working electrode around the pH-ISFET. Appling a voltage to the working electrode, the hydrogen ion which is proportional to the dissolved oxygen concentration occurs around the pH sensing gate and we can measure the dissolved oxygen concentration by detecting pH concentration through the pH-ISFET. In this paper, a dissolved oxygen measurement system using FET-type dissolved oxygen sensor array which adopt a specific algorithm to enhance the reliability has been developed and we compared its performance with the commercial dissolved oxygen measurement system.

  • PDF

OPTIMIZATION OF CULTURE CONDITIONS FOR PRODUCTION OF PNEUMOCOCCAL CAPSULAR POLYSACCHARIDE TYPE I

  • Kim, S.N.;K.K. Min;Kim, S.H.;Park, I.H.;Lee, S.H.;S.N. Pyo;D.K. Rhee
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.186-186
    • /
    • 1996
  • Streptococcus pneumoniae (pneumococcus), the most common cause of bacterial pneumonia, has an ample polysaccharide(PS) capsule that is highly antigenic and is the source of PS vaccine. This investigation was undertaken to optimize the culture conditions for the production of capsular PS by type 1 pneumococcus. Among several culture media, brain heart infusion (BHI) and Casitone based media were found to support luxuriant growth of pneumococcus type 1 at the same level. Because BHI medium is rather expensive and more complex than the Casitone based media, the Casitone based media was used to study optimization of the culture condition. The phase of growth which accomodated maximum PS production was logarithmic phase. Concentrations of glucose greater than 0.2% did not enhance growth or PS production. Substitution of nitrogen sources with other resources or supplemention of various concentrations of metal ion (with the exception of calcium ion) had adverse effects on growth and PS production. On the other hand, low level aeration was beneficial for increased PS production. Addition of 3 mg/I concentration of methionine, phenylalanine, and threonine were found to enhance growth and PS production. The synergistic effect of all the favorable conditions observed in pneumococcal growth assays provided a two-fold cumulative increase in capsular PS production.

  • PDF

Effect of Amine Nature on Rates and Mechanism: Pyridinolyses of 4-Nitrophenyl Benzoate

  • Um, Ik-Hwan;Baek, Mi-Hwa;Han, Hyun-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1245-1250
    • /
    • 2003
  • Pseudo-first-order rate constants ($k_{obs}$) have been measured spectrophotometrically for the reactions of 4-nitrophenyl benzoate with a series of pyridines in $H_2O$ containing 20 mol % DMSO. The plots of kobs vs pyridine concentration are linear up to ca. 0.1 M pyridines, indicating that the effect of self-association of pyridines with their conjugate acids are insignificant in this concentration range. The Bronsted-type plot has been obtained to be linear with a ${\beta}_{nuc}$ value 1.11, suggesting that the pyridinolyses proceed through a rate-determining breakdown of the zwiterionic addition intermediate. The pyridines studied have shown higher reactivity than isobasic primary and secondary amines toward the substrate. 1-Benzoyl-4-dimethylaminopyridinium ion, a possible intermediate, has not been detected since the rate of its hydrolysis in the reaction condition is comparable with or even faster than its formation.

Analysis of Discharge Characteristics and Fire Risk of Mobile Phone Batteries according to the Concentration of Salt Water (염수농도에 따른 휴대폰 배터리의 방전특성과 화재 위험성 분석)

  • Woo, Jin-Su;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.66-71
    • /
    • 2020
  • The process of discharging batteries using salt water, when used for the disposal of a lithium-ion (Li-ion) batteries, is likely to cause a fire. However, there is a dearth of studies in the literature on the risk of fire while discharging mobile phone batteries in salt water. In order to investigate the possibility of fire by elucidating the discharge characteristics and the generation of heat, we conducted experiments by varying the concentration of the salt water, number of overlapping batteries, and type of the mobile phone batteries used as experimental specimen. The discharging voltage and the temperature of the batteries were measured, and the fire risk was predicted by analyzing the data. The results of the experiment showed that the higher the salt water concentration, the greater the discharge value of the mobile phone battery and the higher the exothermic temperature. Moreover, the exothermic temperatures of the overlapping batteries were higher than that of the single battery submerged in salt water. The highest exothermic temperature points of the battery occurred at the positive and negative poles.

Influence of Mineral Admixtures on the Diffusion Coefficient for Chloride Ion in Concrete (광물질 혼화재가 콘크리트의 염소이온 확산계수에 미치는 영향)

  • Bae, Su-Ho;Park, Jae-Im;Lee, Kwang-Myong;Choi, Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.347-353
    • /
    • 2009
  • The qualitative factors influencing the ingress of chloride ion into concrete are water-binder (W/B) ratio, cement type, age, chloride ion concentration of given environment, wet and dry conditions, etc. Thus, an objective of this experimental research is to investigate the effects of cement types and environmental conditions on the chloride ion diffusion characteristics in concrete through the chloride ion diffusion test. For this purpose, the diffusion coefficients for chloride ion in concrete with three types of cement such as ordinary portland cement (OPC), binary blended cement (BBC), and ternary blended cement (TBC), were measured for the concrete specimens with W/B ratios of 32%, 38%, and 43%, respectively. The diffusion coefficients for chloride ion were also measured for the concrete specimens with W/B ratio of 43%, which were subjected to standard curing and field exposure conditions. It was observed from the test results that the resistance against chloride ion penetration increased with decreasing W/B ratio and those of BBC and TBC concretes were greater than that of OPC concrete. Therefore, it was revealed that the use of these cements containing mineral admixtures is required to extend the service life of RC structures exposed to chloride environment. On the other hand, it was noted that the resistance against chloride ion penetration of field exposure test specimens was slightly lower than that of standard curing test specimens due to the penetration of chloride ion under the irregular ambient temperature, splash of wave, and cycle of wet and dry.