• Title/Summary/Keyword: Ion Pair Liquid Chromatography

Search Result 20, Processing Time 0.021 seconds

Determination of Fluorescent Whitening Agents in Paper Materials by Ion-Pair Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Jeong Soo;Kim, Do Hwan;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3971-3976
    • /
    • 2012
  • A simple method was developed for the analysis of seven stilbene-type fluorescent whitening agents (FWAs) in paper materials by ion-pair reversed-phase high-performance liquid chromatography with fluorescence detection. These stilbene-type FWAs included two disulfonate, two tetrasulfonate, and three hexasulfonate compounds. After optimization of chromatographic conditions, the FWAs were satisfactorily separated using a reversed-phase column (RP-18) with the following isocratic mobile phase: methanol-water (60:40) containing 17.5 mM TBABr and 10 mM citrate buffer (pH = 7.0). The calibration plot was linear in the range from 5 to 500 ng/mL for two disulfo-FWAs and from 1 to 500 ng/mL for the other five FWAs. Precision levels of the calibration curve as indicated by RSD of response factors were 1.2 and 8.1%. Limits of quantitation (LOQ) ranged from 1.2 to 11 ng/mL.

Simultaneous Determination of Tar Color Additives in Cold Syrups by Ion Pair-high Performance Liquid Chromatography (이온쌍-고성능 액체크로마토그래피에 의한 감기약 시럽에서 타르색소 첨가물의 동시분석)

  • Jin, Jing-Yu;Huang, Hu;Lee, Beom-Gyu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.459-465
    • /
    • 2010
  • A simple and efficient analytical method for the simultaneous determination of seven tar color additives was developed using ion pair high performance liquid chromatography. The conditions for HPLC analysis were as follows: column, ${\mu}$-Bondapak C18 (10 ${\mu}m$, 300 ${\times}$ 3.9 mm i.d.); gradient mobile phase, 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrile-methanol (65:25:10) as a mobile for fraction A and 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrilemethanol (40:50:10) as a mobile for fraction B; flow rate, 1.0 mL/ min; detection wavelength, 254/520/620 nm. We could attain to the detection limits as 0.01~0.05 ${\mu}$g/mL (254 nm) and 0.005~0.01 ${\mu}$g/mL (520 nm) for six red tar color additives, and 0.05 ${\mu}$g/mL (254 nm) and 0.002 ${\mu}$g/mL (620 nm) for Fast green FCF. This analytical method was applicable to determine the tar color additives contained in several commercial cold syrups.

Mutation Analysis in β2-Adrenergic Receptor Gene by Denaturing High Performance Liquid Chromatography (DHPLC) (DHPLC를 이용한 β2-교감신경수용체 유전자에서의 돌연변이 분석)

  • Park, Sang-Bum;Oh, Chung-Hun;Kim, Jong-Wan;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.190-195
    • /
    • 2002
  • We analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed-phase high performance liquid chromatography (IP-RP-HPLC). We extracted genomic DNA from 50 asthma patients, amplified DNA using PCR, and analysed PCR product by DHPLC. As a result, we obtained that mutation frequency was 15 (30%) among 50 cases. Consequently DHPLC mutation detection was confirmed that the result of direct sequencing was coincide exactly.

Determination of Theophylline and its Metabolites in Human Urine by High-Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Park, Young-Hwan;Park, Hyo-Kyung;Kim, Ho-Soon;Lee, Min-Hwa
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.396-399
    • /
    • 1996
  • High-performance liquid chromatographic method with UV detecction was developed for the determination of theophylline and its metabolites in human urine using ${beta}$-hydroxyethyl theophylline$({beta} -HET)$ as an internal standard. For extraction of urine sample, quality control sample and xanthine-free blank urine were mixed with decylamine (ion-paring reagent) and ${beta}$-HET. After saturation with ammonium sulfate, the mixture was then extracted with organic solvent at pH values of 4.0-4.5. All separations were performed with ion-pair chromatography using decylamine as an ion-pairing reagent and 3mM sodium acetate buffered mobile phase (pH 4.0) containing 1% (v/v) acetonitrile and 0.75 mM decylamine. The detection limits of theophylline, 1, 3-DMU, 1-MU, 3-MX and 1-MX in human urine were 0.17, 0.17, 0.39, 0.19 and 0.19 ${\mu}g$/ml, based on a signal-to-noise ratios of 3.0. The mean intraday coefficients of variation (C.V.s) of each compound on nine replicates were lower than 2.0%, while mean interday C.V.s on three days were lower than 1.6%. All separations were finished within 40miutes.

  • PDF

Separation and Determination of Acteoside in Pedicularis resupinata var. oppositifolia by Ion Pair Liquid Chromatography (이온쌍 액체 크로마토그래피에 의한 마주송이풀 중의 Acteoside의 분리와 정량)

  • Yun, Young Ja;Yu, Gu Yong
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.161-166
    • /
    • 1995
  • Determination of acteoside in Pedicularis resupinata var. oppositifolia has been studied using ion pair liquid chromatography. Sample was extracted with 40mL methanol for 4 hrs. The extract was cleaned up by using Sep-Pak $C_{18}$ catridge and 8mL aqueous methanol eluent(methanol 50%, water 50%, phosphate buffer pH=8.0). Its determination was performed by means of IP-HPLC with a Hamilton PRP-1 polystyrene-divinylbenzene reversed phase column($15cm{\times}4.6mm$ i. d., $5{\mu}m$) and an aqueous methanol eluent(methanol 60%, water 40% phosphate buffer pH=8.2) containing of $5.0{\times}10^{-3}M$ tetrabutylammonium bromide. The established method was applied to the sample that was collected in area of Pyung Chang gun. As a result, its content ranges showed to be 0.062~0.076%.

  • PDF

Liquid Chromatography of Aromatic Sulfonic Acids by Tetramethylammonium Bromide (Tetramethylammonium Bromide를 이용한 방향족 술폰산들의 액체크로마토그래피)

  • Oh, Hae-Beom
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.9
    • /
    • pp.793-799
    • /
    • 1993
  • Ion-pair model was predominated over ion-interaction model in the retention mechanism of analytes when tetramethylammonium bromide (TMAB) was used as a counter-ion in the investigation of aromatic sulfonic acids on the reversed-phase liquid chromatography by $C_{18}$ column as a stationary phase. The capacity factors of analytes were influenced by the type and concentration of counter-ions, concentrations of methanol and co-anion, types and position of functional group, and the pH mobile phase. Components of analyte mixture could be separated under the optimum conditions by this method.

  • PDF

Mutation Analysis in β2-Adrenergic Receptor Gene by Single Strand Conformation Polymorphism (SSCP) and Denaturing High Performance Liquid Chromatography (DHPLC) (SSCP와 DHPLC에 의한 β2-교감신경수용체 유전자의 돌연변이 분석)

  • Park, Sang-Bum;Han, Sang-Man;Nam, Youn-Hyoung;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • Up to now, methods for the detection of genetic alterations as single strand conformation polymorphism (SSCP) or denaturing gradient gel electrophoresis (DGGE) have been used. It is too labor-intensive and expensive to serve for routine analysis. Moreover, lower in its sensitivity and specificity being also strongly dependent on the experience of the investigater. To improve these problems, we analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed phase chromatography (IP-RPC). We extracted genomic DNA from 80 asthma patients and then amplified DNA using PCR and analysed PCR product by SSCP and DHPLC. As a result, we analysed mutation frequency is 19 (23.75%) on SSCP and 25 (31.25%) on DHPLC in ${\beta}_2$-adrenergic receptor gene. We conclude that DHPLC is a fast and simple screening method rather than SSCP analysis.

Analysis of Kasugamycin in Pesticide Formulations by Reversed-Phase Ion Pair Liquid Chromatography (역상 이온쌍 액체크로마토그래피에 의한 농약 제품 중 Kasugamycin의 분석)

  • Kim, Taek-Jae;Kim, Kyong-Sun;Yoon, Chae-Hyuk;Joo, Jin-Bok;Kim, Chung-Hyo
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.343-349
    • /
    • 1997
  • Analytical method using the reversed phase ion-pair chromatography (RP-IPC) for the determination of kasugamycin(5-amino-2-methyl-6-(2,3,4,5,6-pentahydroxy cyclohexyloxy)tetrahydropyran-3-yl-amino-${\alpha}$-imino acetic acid), pesticide as fungicide bactercide has been established. The retention behavior of kasugamycin in the RP-IPC was examined with respect to the effect of concentrations of organic modifiers, pH of eluent and types and concentrations of the counter ions as ion-pair reagent. This method developed by the optimum factors, can be used for the application of the quality control in the crude product and its formulation.

  • PDF

Determination of Boron by Ion Pair Liquid Chromatography with Chromotropic Acid (Chromotropic Acid를 착화제로 이용한 이온쌍 액체 크로마토그래피에 의한 붕소의 분리와 정량)

  • Yun, Young Ja;Yu, Gu Yong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.288-293
    • /
    • 1995
  • The separation and determination of boron with chromotropic acid (1,8-Dihydroxynaphthalene-3,6-disulfonic acid) as a complex agent has been studied using ion pair liquid chromatography. The use of tetrabutylammonium bromide added as an ion pair reagent to mobile phase (MeOH 61%, phosphate buffer 39% pH=8.5) allowed good separation of boron-chromotrophic acid complex anion and chromotrophic acid on poly(styrene-divinylbenzene) based reversed phase column (PRP-1, 15 $cm{\times}4.6$ mm i.d.). The complex formation between boric acid and chromotrophic acid was enhanced in the presence of 0.1 M tetrabutylammonium bromide, resulting in high sensitivity. The linear calibration was achieved over the boron concentration range of 0.5∼1000 ${\mu}g/L.$ The detection limit was 0.5 ${\mu}g/L$ (S/N=2). The proposed method was applied to the determination of boron in commercially available chemicals, $Na_2SO_4$, NaOH, KCl.

  • PDF

Ion-Pair High Performance Liquid Chromatographic Retention Behavior of Salicylic Acid and Its Derivatives (살리실산 및 그 유도체들의 이온쌍 고성능액체크로마토그래피 머무름 거동)

  • Lee, Kangwoo;Chung, Yongsoon;Oh, Sangkeun
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.203-208
    • /
    • 1999
  • The ion-pair high performance liquid chromatographic elution behavior of salicylic acid and its derivatives was studied with measuring capacity factor, k', changing the concentration of ion-pairing reagent (tetrabutylammonium chloride, TBACl) in mobile phase. As a result, it was found that k' of the samples increase at pH 7.2 as the TBACl concentration increases. The derivatives of salicylic acid were separated each other at an optimum mobile phase condition which was found from the observation of the retention behavior. The optimum mobile phase condition was methanol solution($MeOH:H_2O_2$ 30:70) containing 20 mM TBACl for the determination of salicylic acid and methanol solution($MeOH:H_2O_2$ 20:80) containing 40 mM TBACl for p-aminosalicylic acid at pH 7.2. The method has been applied for the analysis of the contents of salicylic acid derivatives in an aspirin tablet and a tuberculosis curing agent.

  • PDF