• Title/Summary/Keyword: Ion Irradiation

Search Result 453, Processing Time 0.022 seconds

Functionalization of polyethylene by graft copolymerization for separation processes

  • Kaur, Inderjeet;Gupta, Nitika;Kumari, Vandna
    • Advances in materials Research
    • /
    • v.2 no.1
    • /
    • pp.15-36
    • /
    • 2013
  • Incorporation of polar functional moieties into polyethylene (PE) film has been achieved by graft copolymerization of polar monomers such as methacrylic acid (MAAc) and acrylamide (AAm) on to PE film, preirradiated with ${\gamma}$-rays from $^{60}Co$ source, using benzoyl peroxide (BPO) as initiator in aqueous medium. Percentage of grafting of MAAc and AAm was determined as a function of irradiation dose, monomer and initiator concentration, temperature, reaction time and amount of water. Maximum percentage of grafting of MAAc (1453%) and AAm (21.28%) was obtained at [MAAc] = $235.3{\times}10^{-2}$ mol/L, [AAm] = $23.4{\times}10^{-2}$ mol/L, [BPO] = $5.5{\times}10^{-2}$ mol/L and $16.5{\times}10^{-2}$ mol/L at $80^{\circ}C$, $90^{\circ}C$ in 180 min and 90 min respectively. The grafted PE films were characterized by FTIR, Thermogravimetric analysis (TGA) Scanning Electron Micrography (SEM) and X-ray diffraction methods. Some selective properties of grafted films such as swelling behavior, ion and metal uptake have been carried out. The biodegradation studies of the grafted PE films have also been investigated. The grafted films developed superior swelling behavior with maximum swelling (480%) in water as compared to pristine PE (13.55%), better thermal stability and ion and metal uptake studies showed promising results that can be effectively used for desalination of brackish water and separation of metals from the industrial effluents.

Dielectric properties of Pt/PVDF/Pt modified by low energy ion beam irradiation

  • Sung Han;Yoon, Ki-Hyun;Jung, Hyung-Jin;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.110-110
    • /
    • 1999
  • Polyvinylidenefluoride (PVDF) is most used in piezoelectric polymer industry. Electrode effect on the electrical properties of PVDF has been investigated. al has been used due to fair adhesion for PVDF. Work function of metal plays an important role on the electrical properties of ferroelectrics for top and /or bottom electrode. However, Al has much lower work function than Pt or Au and so leakage current of Al/PVDF/Al may be large. Pt or Au has not been used for electrode of PVDF system due to poor adhesion. PVDF irradiated by Ar+ ion beam with O2 environment takes good adhesion to inert metal. Contact angle of PVDF to triple distilled water was reduced from 75$^{\circ}$ to 31$^{\circ}$ at 1$\times$1015 Ar+/cm2. Working pressure was 2.3$\times$10-4 Torr and base pressure was 5$\times$10-6 Torr. Pt was deposited by ion beam sputtering and thickness of pt film was about 1000$\AA$. in previous study, enhancing adhesion of Pt on PVDF was shown. in this study, effect of electrode on PVDF will be represented.

  • PDF

Synthesis of Multifunctional Polypropylene-g-(acrylic acid/styrene) Fibrous Ion Exchanger by Electron Beam and Adsorption Properties of Lithum Ion (전자선 조사에 의한 다관능 Polypropylene-g-(acrylic acid/styrene) 섬유상 이온교환체의 합성과 리튬이온 흡착특성)

  • 황택성;박진원;이재천
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.763-769
    • /
    • 2000
  • The multifunctional cation exchangers, sulfonated polypropylene-g-(acrylic acid/styrene) [PP-g-(AAc/Sty)] were synthesized by the irradiational grafting of AAc and Sty onto PP staple fabric with electron beam accelerator and its subsequent sulfonation. The highest degree of grafting obtained was 190% at a monomer mixture of 30 vol% AAc: 70 vol% Sty and a solvent mixture of 30 vol% water : 70 vol% methanol and the degree of grafting decreased with an increase of the AAc content in the monomer mixture at constant solvent content. Maximum ion exchange capacity of the copolymer was 4.6 meq/g. The Li$^{+}$ adsorption ability of the copolymer synthesized in the study was the best among PP-g- AAc, sulfonated PP-g-Sty, and sulfonated PP-g-(AAc/Sty).).

  • PDF

Binder-free Sn/Graphene Nanocomposites Prepared by Electrophoretic Deposition for Anode Materials in Lithium Ion Batteries

  • Bae, Eun Gyoung;Hwang, Yun-Hwa;Pyo, Myoungho
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1199-1204
    • /
    • 2013
  • Nanocomposites consisting of Sn nanoparticles and graphene oxide (GO) were electrophoretically deposited onto Cu current collectors that was used for anodes in Li ion batteries (LIBs). In order to optimize the electrochemical performance of nanocomposites as an anode material by controlling the oxygen functionality, the GO was subjected to $O_3$ treatment prior to electrophoretic deposition (EPD). During thermal reduction of the GO in the nanocomposites, the Sn nanoparticles were reduced in size, along with the formation of SnO and/or $SnO_2$ at a small fraction, relying on the oxygen functionalities of the GO. The variation in the duration of time for the $O_3$ irradiation resulted in a small change in total oxygen content, but in a significantly different fraction of each functional group in the GO, which influenced the Sn nanoparticle size and the amount of SnO (and/or $SnO_2$). As a result, the EPD films prepared with the GO that possessed the least amount of carboxylic groups (made by treating GO in an $O_3$ environment for 3 h) showed the best performance, when compared with the nanocomposites composed of untreated GO or GO that was $O_3$-treated for a duration of less than 3 h.

AN INVESTIGATION ON THE CHARACTERIZATION OF COMPOSITE RESIN POLYMERIZED BY THE USE OF AN ARGON ION LASER (Argon 이온 레이저 중합에 의한 Composite resin의 물성에 관한 연구)

  • Cho, Hyung-Kyung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.69-82
    • /
    • 1992
  • An experimental investigation of the physical properties of light curing composite resin P-50 was performed, in which an argon ion laser beam was irradiated. The physical and mechanical properties of laser polymerized composite resin were determined by measuring the compressive strength, diametral tensile strength, curing depth and microhardness depending upon the experimental conditions such as the laser irradiation time(10sec, 20sec, 30sec) and laser power(300mW, 500mW, 1000mW). These observations were compared with a conventional visible light curing technique. In addition, to evaluate the marginal adaptation, Class V cavity was prepared on the buccal or lingual surface of the extracted premolar and filled with P-50 light curing resin. The test samples were irradiated with both light sources so that the interface between the restoration and the tooth structure were observed under scanning electron microscope. The most of physical and mechanical properties of the laser cured resin showed a remarkable improvement than those treated with the conventional light source, while the observations with the scanning electron microscope provided no significant difference for two polymerized sources. From the results in the experiment it appears that the potential of an argon ion laser is of important value of the use in the polymerization of composite resin.

  • PDF

Real Time Monitoring of Ionic Species Generated from Laser-Ablated Pb$(Zr_{0.52}Ti_{0.48})O_3$ Target Using Pulsed-Field Time-Of-Flight Mass spectrometer

  • 최영구;임훙선;정광우
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.830-835
    • /
    • 1998
  • The characteristics of the ablation plume generated by 532 nm Nd: YAG laser irradiation of a Pb(Zr0.52Ti0.48)O3 (PZT) target have been investigated using a pulsed-field time-of-flight mass spectrometer (TOFMS). The relative abundance of O+, Ti+, Zr+, Pb+, TiO+, and ZrO+ ions has been measured and discussed. TiO+ and ZrO+ ions were also found to be particularly stable within the laser ablation plasma with respect to PbO+ species. The behavior of the temporal distributions of each ionic species was studied as a function of the delay time between the laser shot and the ion extraction pulse. The most probable velocity of each ablated ion is estimated to be Vmp=1.1-1.6x 105 cm/s at a laser fluence of 1.2 J/cm2, which is typically employed for the thin film deposition of PZT. The TOF distribution of Ti+ and Zr+ ions shows a trimodal distribution with one fast and two slow velocity components. The fast velocity component (6.8x 10' cm/s) appears to consist of directly ablated species via nonthermal process. The second component, originated from the thermal evaporation process, has a characteristic velocity of 1.4-1.6 x 105 cm/s. The slowest component (1.2 x 105 cm/s) is composed of a dissociation product formed from the corresponding oxide ion.

Zinc Ions Affect Siderophore Production by Fungi Isolated from the Panax ginseng Rhizosphere

  • Hussein, Khalid Abdallah;Joo, Jin Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.105-113
    • /
    • 2019
  • Although siderophore compounds are mainly biosynthesized as a response to iron deficiency in the environment, they also bind with other metals. A few studies have been conducted on the impact of heavy metals on the siderophore-mediated iron uptake by microbiome. Here, we investigated siderophore production by a variety of rhizosphere fungi under different concentrations of $Zn^{2+}$ ion. These strains were specifically isolated from the rhizosphere of Panax ginseng (Korean ginseng). The siderophore production of isolated fungi was investigated with chrome azurol S (CAS) assay liquid media amended with different concentrations of $Zn^{2+}$ (50 to $250{\mu}g/ml$). The percentage of siderophore units was quantified using the ultra-violet (UV) irradiation method. The results indicated that high concentrations of $Zn^{2+}$ ion increase the production of siderophore in iron-limited cultures. Maximum siderophore production by the fungal strains was detected at $Zn^{2+}$ ion concentration of $150{\mu}g/ml$ except for Mortierella sp., which had the highest siderophore production at $200{\mu}g/ml$. One potent siderophore-producing strain (Penicillium sp. JJHO) was strongly influenced by the presence of $Zn^{2+}$ ions and showed high identity to P. commune (100% using 18S-rRNA sequencing). The purified siderophores of the Penicillium sp. JJHO strain were chemically identified using UV, Fourier-transform infrared spectroscopy (FTIR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF-MS) spectra.

Estimation of radionuclides leaching characteristics in different sized geopolymer waste forms with simulated spent ion-exchange resin

  • Younglim Shin;Byoungkwan Kim;Jaehyuk Kang;Hyun-min Ma;Wooyong Um
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3617-3627
    • /
    • 2023
  • This study presents a method to solidify spent ion-exchange resin (IER) in a metakaolin-based geopolymer and shows results of mechanical strength, immersion, leaching, irradiation, and thermal cycling tests for waste acceptance criteria (WAC) to repository. The geopolymer waste form with 20 wt% of simulated spent IER met the WAC in South Korea (ROK), and the leaching tests of various sized-waste forms up to 15.0 × 30.0 cm and waste loadings up to 20 wt% for 1-5 d and 1-90 d achieved a leachability index, Li > 6. In a leaching test for 5 d, the cumulative fraction leached (CFL) for Cs, which leached the most, was linearly correlated with the square root of leaching time for all waste forms, and Li increased as the size of the waste form increased. The CFL was also correlated with elapsed time in the 90 d leaching test. The correlations among CFL, time, and volume-to-surface area ratio of waste forms used to estimate the Li of Cs of a 200-L sized geopolymer with 15 wt% IER showed the Li values as 14.73 (5 d) and 17.71 (90 d), respectively, indicating that the large-sized geopolymer waste form met the WAC.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Indium Tin Oxide(ITO) Thin Film Deposition on Polyethylene Terephthalate(PET) Using Ion Beam Assisted Deposition(IBAD)

  • Bae, J.W.;Kim, H.J.;Kim, J.S.;Lee, Y.H.;Lee, N.E.;Yeom, G.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.81-83
    • /
    • 2000
  • Tin-doped indium oxide(ITO) thin films were deposited on polyethylene terephthalate(PET) at room temperature by oxygen ion beam assisted evaporator system and the effects of oxygen gas flow rate on the properties of room temperature ITO thin films were investigated. Plasma characteristics of the ion gun such as oxygen ions and atomic oxygen radicals as a function of oxygen flow rate were investigated using optical emission spectroscopy(OES). Faraday cup also used to measure oxygen ion density. The increase of oxygen flow rate to the ion gun generally increase the optical transmittance of the deposited ITO up to 6sccm of $O_2$ and the further increase of oxygen flow rate appears to saturate the optical transmittance. In the case of electrical property, the resistivity showed a minimum at 6 sccm of $O_2$ with the increase of oxygen flow rate. Therefore, the improved ITO properties at 6 sccm of $O_2$ appear to be more related to the incorporation of low energy oxygen radicals to deposited ITO film rather than the irradiation of high energy oxygen ions to the substrate. At an optimal deposition condition, ITO thin films deposited on PET substrates showed the resistivity of $6.6{\times}10^{-4}$ ${\Omega}$ cm and optical transmittance of above 90%.

  • PDF