• 제목/요약/키워드: Ion Current

검색결과 1,479건 처리시간 0.029초

플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향 (Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma)

  • 황휘동;구치욱;정경재;최재명;김곤호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

Discharge Characteristics of a KSTAR NBI Ion Source

  • Chang Doo-Hee;Oh Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.226-233
    • /
    • 2003
  • The discharge characteristics of a prototype ion source was investigated, which was developed and upgraded for the NBI (Neutral Beam Injection) heating system of KSTAR (Korea Superconducting Tokamak Advanced Research). The ion source was designed for the arc discharge of magnetic bucket chamber with multi-pole cusp fields. The ion source was discharged by the emission-limited mode with the control of filament heating voltage. The maximum ion density was 4 times larger than the previous discharge controlled by a space-charge-limited mode with fully heated filament. The plasma (ion) density and arc current were proportional to the filament voltage, but the discharge efficiency was inversely proportional to the operating pressure of hydrogen gas. The maximum ion density and arc current were obtained with constant arc voltage ($80{\sim}100V$), as $8{\times}10^{11}cm^{-3}$ and 1200 A, respectively. The estimated maximum beam current was about 35 A, extracted by the accelerating voltage of 80kV.

흰쥐 신경세포에서 억제성 및 흥분성 한약재가 유발한 이온전류의 특성 (Characterization of ion current induced by inhibitory and excitatory herbs in rat periaqueductal gray neuron)

  • 이충열;조선혜;서종은;한승호;조영욱;민병일;김창주
    • 대한한의학회지
    • /
    • 제19권2호
    • /
    • pp.450-467
    • /
    • 1998
  • To research the characteristics of ion currents induced by inhibitory and excitatory herbs of oriental medicine, we used nystatin-perforated patch clamp technique under voltage clamp condition in periaqueductal gray neuron dissociated from Sprauge-Dawley rat, 10-15 days old. The results are as follows. 1. Ion current induced by $10mg/m{\ell}$ of Bupleuri Radix was inhibited $59.50{\pm}4.29%$ by $10^{-4}M$ bicuculline(p>0.01) but inhibition of $10.75{\pm}4.77%$ by $10^{-4}M$ tubocurarine and $4.75{\pm}4.23%$ by $10^{-4}M$ verapamil had no statistical significance(p>0.05). So ion current induced by Bupleuri Radix revealed only GABA induced $Cl^-$ current, not acetylcholine and $Ca^{2+}$ current. 2. Ion current induced by $20mg/m{\ell}$ of Coptidis Rhizoma was inhibited $47.20{\pm}7.88%$ by $10^{-4}M$ bicuculline(p<0.01) but $3.20{\pm}2.33%$ inhibition by $10^{-4}M$ tubocurarine and $1.00{\pm}1.00%$ inhibition by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Coptidis Rhizoma revealed only GABA induced $Cl^-$ current, not acetylcholine and $Ca^{2+}$ current. 3. Ion current induced by $20mg/m{\ell}$ of Ecliptae Herba was inhibited $55.00{\pm}4.92%$ by $10^{-4}M$ bicuculline (p<0.01), and also inhibited $15.00{\pm}4.26%$ by $10^{-4}M$ tubocurarine(p<0.05), but inhibition of $6.00{\pm}3.03%$ by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Ecliptae Herba showed GABA activated $Cl^-$ current and acetylcholine activated cation current, not $Ca^{2+}$ current 4. Ion current induced by $5mg/m{\ell}$ of Liriopis Tuber was inhibited $15.20{\pm}4.57%$ by $10^{-4}M$ bicuculline<0.05) and also inhibited $14.00{\pm}3.00%$ by $10^{-4}M$ tubocurarine(p<0.05), but inhibition of $5.20{\pm}4.80%$ by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Liriopis Tuber showed GABA. activated $Cl^-$ current and acetylcholine activated cation current, not $Ca^{2+}$ current. 5. Ion current induced by $5mg/m{\ell}$ of Aconiti Tuber was inhibited $97.00{\pm}1.34%$ by $10^{-4}M$ bicuculline(p<0.01), $80.00{\pm}9.83%$ by $10^{-4}M$ tubocurarine(p<0.01), and $24.00{\pm}6.18%$ by $10^{-4}M$ verapamil(p<0.05). So ion current induced by Aconiti Tuber revealed GABA activated $Cl^-$ current and acetylcholine activated cation current and $Ca^{2+}$ current. 6. Ion current induced by $10mg/m{\ell}$ of Zingiberis Rhizoma was inhibited $33.00{\pm}7.43%$ by $10^{-4}$ bicuculline(p<0.05), $10.20{\pm}1.83%$ by $10-^{-4}M$ tubocurarine(p<0.01), and $14.00{\pm}2.16%$ by $10^{-4}M$ verapamil(p<0.01) So ion current induced by Zingiberis Rhizoma revealed GABA activated $Cl^-$ current and acetylcholine activated cation outtent and $Ca^{2+}$ current. 7. Ion current induced by $10mg/m{\ell}$ of Boshniakiae Herba was inhibited $65.00{\pm}13.75%$ by $10^{-4}M$ bicuculline(p<0.05), $38.00{\pm}9.24%$ by $10^{-4}M$ tubocurarine(p<0.05), and $33.25{\pm}7.42%$ by $10^{-4}M$ verapamiHp<0.05). So ion current induced by Bpshniakiae Herba revealed GABA activated $Cl^-$ current and acetylcholine activated cation current and $Ca^{2+}$ current. These results suggest that a point of difference between inhibitory and excitatory herbs is existence of$Ca^{2+}$ current.

  • PDF

Modulation of Corydalis tuber on Glycine-induced Ion Current in Acutely Dissociated Rat Periaqueductal Gray Neuron

  • Cheong, Byung-Shik;Nam, Sang-Soo;Choi, Do-Young
    • 대한한의학회지
    • /
    • 제24권4호
    • /
    • pp.34-42
    • /
    • 2003
  • This study was designed to investigate the modulation of the Corydalis tuber on glycine-activated ion current in rat periaqueductal gray (PAG) neurons. Aqueous extract from Corydalis tuber has been widely used for pain control such as dysmenorrhea, irregular menstruation or amenorrhea with abdominal cramping, neuralgia, headache and gastrointestinal spasm. The PAG region of the brain is known to be involved heavily with nociception. Modulation of the Corydalis tuber on glycine-induced ion current in rat periaqueductal gray (PAG) neurons was studied by a nystatin-perforated patch-clamp technique. High concentrations of Corydalis tuber elicited ion current, which was suppressed by strychnine application. Low concentrations of Corydalis tuber reduced glycine-induced ion currents in the PAG neurons. Inhibitory action of Corydalis tuber on glycine-activated ion current was reduced by treatment with naltrexone, a non- selective opioid antagonist. Application of N-methylmalemide (NEM), a sulfhydryl alkylating agent, also reduced the inhibitory action of Corydalis tuber on glycine-activated ion current in the PAG neurons. These results suggest that the inhibitory effect of Corydalis tuber on glycine-activated ion current in the PAG neurons is one of the analgesic mechanisms of the Corydalis tuber, which may activate descending pain control system in PAG neurons.

  • PDF

SCBF 장치에서 이온전류에 대한 포텐셜 우물 구조의 영향 (Effect of Potential Well Structure on Ion Current in SCBF Device)

  • 주흥진;박정호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.471-477
    • /
    • 2007
  • SCBF(Spherically Convergent Beam Fusion) device has been studied as a neutron source. Neutron production rate is a most important factor for the application of SCBF device and is proportional to the square of the ion current[1]. It is regarded generally that some correlations between the potential well structure and the ion current exist. In this paper, the ion current and potential distribution were calculated in a variety of grid cathode geometries using FEM-FCT method. Single potential well structure was certified inside the grid cathode. The deeper the potential well became, the higher the ion current due to the high electric field near the grid cathode became.

이온유체방정식을 이용한 Plasma Sheath 시변 해석 (Analysis of Time-Dependent Behavior of Plasma Sheath using Ion Fluid Model)

  • 이호준;이해준
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2173-2178
    • /
    • 2007
  • Dynamics of plasma sheath was analyzed using simple ion fluid model with poison equation. Incident ion current, energy, potential distribution and space charge density profile were calculated as a function of time. The effects of initial floating sheath on the evolution of biased sheath were compared with ideal matrix sheath. The effects of finite rising time of pulse bias voltage on the ion current and energy was studied. The influence of surface charging on the evolution of sheath was also investigated

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

초고압 직류 가공송전 후보 도체방식의 이온류 환경특성 코로나 케이지 모의시험 (Corona Cage Simulation on Environmental Characteristics Caused by the Ion flow of Candidated Conductor Bundles for HVDC Overhead Transmission)

  • 주윤노;양광호;이동일;신구용
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1791-1795
    • /
    • 2007
  • Small ions generated at conductor corona sources remain in the atmosphere until they recombine with ions of opposite polarity, attach to aerosols, or make contact with an object. Ion current density is major factor to design conductor configuration of DC overhead transmission line. Several techniques have been used to measure the ion current of HVDC overhead transmission line. In this study, the ion current density was measured by a plate electrode made of a metal flat board at DC corona cage. The sensitivity of the plate electrode is $0.156uA/m^2/V$. To obtain an useful database on corona discharge, it is necessary to do corona test on several kinds of conductor bundles. Therefore, a number of experiments were conducted on several kinds of conductor bundles. To reliably analyze ion effects, corona cage test data were obtained over a long period of time under various weather conditions and expressed as a statistical distribution. Ion current density distribution in foul weather shows a significant increase in levels over the corresponding fair weather. Based on this results, we evaluated the environmental characteristic caused by ion flow of three candidated conductor bundles.

Effect of Amygdalin from Armeniacae Semen on Ion Currents Changed by Lipopolysaccharide in Rat Periaqueductal Gray Neurons

  • Lee, Gil-Jae;Song, Yun-Kyung;Lim, Hyung-Ho
    • 대한한의학회지
    • /
    • 제28권4호
    • /
    • pp.104-113
    • /
    • 2007
  • Background : Amygdalin is abundant in Armeniacae semen, and it is recently reported to treat cancers and relieve pain. But modus operandi of amygdalin at the level of neuron has not been reported, yet. Objective : This study aimed to find out the effect of amygdalin on glycine- and glutamate-induced ion currents in periaqueductal gray (PAG) neurons. And it was investigated that amygdalin participates in the regulation of the descending pain control system in the level of PAG neurons. Method : We investigated that the changes of glycine- and glutamate-induced ion currents in PAG neurons through application of lipopolysaccharides (LPS) and application of amygdalin with LPS by using the nystatin-perforated patch clamp method. Result : Application of LPS on PAG neurons resulted in increased glycine-induced ion current, and in decreased glutamate-induced ion current. In contrast, application of amygdalin with LPS resulted in decreased glycine-induced ion current increased by LPS, and increased glutamate-induced ion current decreased by LPS. Conclusion : Amygdalin from Armeniacae semen controls glycine- and glutamate-induced ion current by LPS in PAG neurons, and it is suggested that amygdalin participates in the regulation of the descending pain control system in the level of PAG neurons.

  • PDF

Duoplasmatron 이온원에서의 $He^+$ 이온빔 인출에 관한 연구 (A Study on $He^+$ Ion Beam Extraction in the Duoplasmatron Ion Source)

  • Myong-Seop KIM;Hae-iLL BAK
    • Nuclear Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.438-443
    • /
    • 1991
  • 각확산도가 작은 $He^+$ 이온빔 인출전류를 최대로 얻기 위하여 Duoplasmatron 이온원의 동작특성을 조사하였다. 이온원의 기체압력, 아크전류. 전자석 전류, 인출전압등을 변화시키면서 인출되는 $He^+$ 이온빔 전류의 변화를 관찰하였다. 열음극으로는 Ni망위에 BaO와 SrO의 혼합물을 코팅한 산화물 필라멘트를 사용하였으며, 그것의 평균수명은 약 100시간이었다. 인출전류는 아크전류에 선형적으로 비례했다 이온원 전자석전류를 증가시킴에 따라 인출전류는 증가하였지만 빔의 각확산도가 커졌다. 최대의 인출전류는 0.084 Torr의 이온원 압력에서 얻어졌다. 인출전류는 이론에서와 마찬가지로 인출전압의 3/2승에 비례하였다. 5.72 kV의 인출전압에서는 최적인출조건하에서 50 $\mu$A의 인출전류가 얻어졌다.

  • PDF