The Study on the Etching Characteristics of (Ba, Sr)TiO$_3$ Film by Inductively Coupled Plasma (유도결합 플라즈마에 의한(Ba, Sr)TiO$_3$ 박막의 식각 특성 연구)

  • 김승범;이영준;염근영;김창일
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.56-62
    • /
    • 1999
  • In this study, (Ba, Sr)$TiO_3$ thin films were etched with $Cl_2$/Ar gas mixing ratio in an inductively coupled plasma (ICP) by varying the etching parameter such as rf power, dc bias voltage, and chamber pressure. The etch rate was 56 nm/min under $Cl_2$/($Cl_2$+Ar) gas mixing ratio of 0.2, rf power of 600 W, dc bias voltage of 250 V, and chamber pressure of 5 mTorr. At this time, the selectivity of BST to Pt, $SiO_2$ was respectively 0.52, 0.43. The surface reaction of the etched (Ba, Sr)$TiO_3$ thin films was investigated with X-ray photoelectron spectroscopy (XPS). Ba is removed by chemical reaction between Sr and Cl to remove Sr. Ti is removed by chemical reaction such as $TiCl_4$ with ease. The results of secondary ion mass spectrometer (SIMS) analysis compared with the results of XPS analysis and the results were the same.

  • PDF

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

DEVELOPMENT AND EVALUATION OF THE MUON TRIGGER DETECTOR USING A RESISTIVE PLATE CHAMBER

  • Park, Byeong-Hyeon;Kim, Yong-Kyun;Kang, Jeong-Soo;Kim, Young-Jin;Choi, Ihn-Jea;Kim, Chong;Hong, Byung-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • The PHENIX Experiment is the largest of the four experiments that have taken data at the Relativistic Heavy Ion Collider. PHENIX, the Pioneering High Energy Nuclear Interaction eXperiment, is designed specifically to measure direct probes of the collisions such as electrons, muons, and photons. The primary goal of PHENIX is to discover and study a new state of matter called the Quark-Gluon Plasma. Among many particles, muons coming from W-boson decay gives us key information to analyze the spin of proton. Resistive plate chambers are proposed as a suitable solution as a muon trigger because of their fast response and good time resolution, flexibility in signal readout, robustness and the relatively low cost of production. The RPC detectors for upgrade were assembled and their performances were evaluated. The procedure to make the detectors better was optimized and described in detail in this thesis. The code based on ROOT was written and by using this the performance of the detectors made was evaluated, and all of the modules for north muon arm met the criteria and installation at PHENIX completed in November 2009. As RPC detectors that we made showed fast response, capacity of covering wide area with a resonable price and good spatial resolution, this will give the opportunity for applications, such as diagnosis and customs inspection system.

Application for Improving Resource Recover at Clay-Sandy Soil based on Electrokinetic Technology (동전기법을 이용한 점토성-사질토에 존재하는 자원 회수 증진을 위한 적용성 연구)

  • Shin, Sanghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.10
    • /
    • pp.5-9
    • /
    • 2013
  • Electrokinetics technology is proposed for improving the recovery metals ion and oil from clay-sandy soil. In order to restore or extract them from clay-sandy soil, the gas produced by anode chamber is re-injected to the clay-sandy soil(sample). Samples produced in this study were completed to verify the proposed performance for 7 days by gradually increasing the pressure to the final pressure of 30psi($2.11kgf/cm^2$) through the compression process. Before compression, the copper rings were inserted into the sample, allowing us to observe the changes in appearance of copper ring after the end of the experiment. In this study, pressurized module and non-pressurized module were tested, respectively. The condition of test is a continuous process and the voltage gradient is 2V/cm during 24 hours. As a result, the efficiency of pressurized module is better than non-pressurized module.

Etch Characteristics of TiN Thin Films in the Inductively Coupled Plasma System (유도 결합 플라즈마를 이용한 TiN 박막의 식각 특성)

  • Um, Doo-Seung;Kang, Chan-Min;Yang, Xue;Kim, Dong-Pyo;Kim, Chang-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.3
    • /
    • pp.83-87
    • /
    • 2008
  • This study described the effects of RF power, DC bias voltage, chamber pressure and gas mixing ratio on the etch rates of TiN thin film and selectivity of TiN thin film to $SiO_2$ with $BCl_3$/Ar gas mixture. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) with other conditions were fixed, the maximum etch rate of TiN thin film was 170.6 nm/min. When the DC bias voltage increased from -50 V to -200 V, the etch rate of TiN thin film increased from 15 nm/min to 452 nm/min. As the RF power increased and chamber pressure decreased, the etch rate of TiN thin film showed an increasing tendency. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) under others conditions were fixed, the intensity of optical emission spectra from radical or ion such as Ar(750.4 nm), $Cl^+$(481.9 nm) and $Cl^{2+}$(460.8 nm) was highest. The TiN thin film was effectively removed by the chemically assisted physical etching in $BCl_3$/Ar ICP plasma.

Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System (소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.

Effects of Activated Carbon on Growth and Physical Responses of Indoor Plant Dracaena braunii to Alleviate Salt-induced Stress in Water Culture (수경재배 시 염소흡착을 위한 활성탄 처리가 실내식물인 개운죽(Dracaena braunii)의 생육 및 생리에 미치는 영향)

  • Ju, Jin Hee;Son, Hye Mi;Kim, Won Tae;Yoon, Yong Han
    • Journal of Environmental Science International
    • /
    • v.28 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • This study aimed to analyze the growth and physical responsees of Dracaena braunii in response salt accumulation in ornamental water culture and to examine the effect of activated carbon on this growth response. The experiment was conducted in a plant growth chamber and the indoor environmental conditions of the chamber were set at $23{\pm}1^{\circ}C$ temperature, $70{\pm}3%$ humidity, and 1,000 lux brightness. The observation of the growth response of plants in the presence of activated carbon showed that the pH with activated carbon maintained sub-acidic to neutral (6.27~7.32) conditions and showed decreased electric conductivity in the media. As the treatment with added activated carbon showed good growth and physical responses, this indicated that absorption effect of activated carbon had a positive influence on the growth of plants. However, as the absorption effect of activated carbon may decrease over time and the use of high concentrations of activated carbon might cause nutrition shortage, various concentration of activated carbon and their absorption effects need to be investigated in the future.

Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.

Intercomparison of vacuum standards of Korea, United Kingdom, and Japan (진공표준의 국제비교 연구)

  • 홍승수;신용현;임종연;이상균;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.308-313
    • /
    • 1997
  • TDS (Thermal Lkso~ption Spectroscopy)system, for diagnosis of CRT manufacturing process, was designed and constructed. Outgassings and themla1 desorptions from the part or materials of CRT can be measured and analysed with this system at various temperatures. The system is consisted of 3 pirrts. vacuum chamher and pumping system with variable conductance, sample heating stages & their controller, and outgassing measurement devices, like as ion gauge or quadrupole mass spectrometer. The ultimate pressure of the system was under $1\times10^{-7}$ Pa. With the variable conductance system, the effective pumping speed of the chamber could he controlled from sub 11s to 100 11s. The effective pumping speed values were determined by dynamic flow measurement principle. The temperatures and ramp rate of sample were controlled by tungsten heater and PID controller up to $600^{\circ}C$ within t $\pm 1^{\circ}C$$difference to setting value. Ion gauge & QMS were calibrated for quantitative measurements. Some examples of TDS measurement data ;ind application on the CRT process analysis were shown.

  • PDF

Studies on Permeation Enhancers for Ocular Peptide Delivery Systems: Pz-peptide as a Novel Enhancer of Ocular Epithelial Paracellular Permeability in the Pigmented Rabbit

  • Chung, Youn-Bok;Lee, Vincnet H.L.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 1994
  • The objective of this study was to determine whether Pz-peptide, an enhancer of hydrophilic solute permeability in the intestine, could elevate the paracellular permeability of the cornea and conjunctiva in the pigmented rabbit. The in vitro penetration of four hydrophilic solutes, mannitol (MW 182), fluorescein (MW 376), FD-4 (FITC-dextran, 4 KDa), and FD-10 (FITC-dextran, 10 KDa) across the pigmented rabbit cornea and conjunctiva was studied either in the presence or absence of 3 mM enhancers. Drug penetration was evaluated using the modified Ussing chamber. The conjunctiva was more permeable than the cornea to all four markers. EDTA and cytochalasin B showed higher effects on marker transport than Pz-peptide, but Pz-peptide elevated the corneal transport of mannitol, fluoresein, and FD-4 by 50%, 26%, and 50%, respectively, without affecting FD-10 transport. Possibly due to the leakier nature of the conjunctiva, 3 mM Pz-peptide elevated the transport of only FD-4 by about 45%, without affecting the transport of other markers. Furthermore, the transport of Pz-peptide itself across the cornea and conjunctiva increased with increasing concentration in the 1-5 mM range, suggesting that Pz-peptide enhanced its own permeability, possibly by elevating paracellular permeability. Effects of ion transport inhibitors on Pz-peptide transport were then investigated. PZ-peptide penetration was not changed by mucosal addition of $10\;{\mu}M$ amiloride or $10\;{\mu}M$ hexamethylene amiloride, inhibiting serosal $Na^{+}$ exit by $100\;{\mu}M$ ouabain, or replacing $Na^{+}$ with choline chloride in the mucosal side buffer. These results seggested that Pz-peptide enhanced the paracellular permeability of rabbit cornea and conjunctiva and further indicate that ion transporters were not involved in the Pz-peptide induced elevation of paracellular marker permeability.