• Title/Summary/Keyword: Inverter driven system

Search Result 170, Processing Time 0.03 seconds

A Study on Drive System Characteristics of the Ballast for 35W(T5) Fluorescent Lamp using Piezoelectric Transformer (압전 변압기를 이용한 35W(T5)급 형광등 안정기 구동 시스템 특성에 관한 연구)

  • Hwang, L.H.;Jang, J.H.;Na, S.K.;Kim, Y.S.;Ahn, I.S.;Cho, M.T.;Song, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1031-1033
    • /
    • 2006
  • In this study, in order to solve these problems, a new type of electronic ballast, which is composed of rectifier, active power factor corrector, series resonant half bridge inverter and piezoelectric transformer, was proposed for driving T5 fluorescent lamp. Driving of piezoelectric transformer was carried out with input region for the ring electrode and output region for the dot electrode. A 35W (T5) fluorescent lamp was successfully driven by the fabricated ballast with piezoelectric transformer.

  • PDF

Cost-effective Power Module Package using Leadframe and Ceramic substrate

  • Jeon, O-S;Jeun, G-Y;Park, S-Y;Lee, K-H;Kim, B-G
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.04a
    • /
    • pp.9-25
    • /
    • 2001
  • Fairchild has been developing a new class IPM called SPM consisting of dramatic Packaging technology to achieve the lowest cost rind better performance for low power home appliances and industrial AC drive applications. The first Fairchild SPM development with IGBT 600V/15A for washing machine application started in 1999 and was completed successfully. Fairchild SPMs are going to be the best solution for low power inverter-driven AC drive system after 2001. The new SPM Packages like SPM ∥ and SPIM for the next generation IPM with the highest competitiveness (cost & performance) shall be continuouslly developed.

  • PDF

Condition Diagnosis by the Complex Accelerating Degradation for Fault Prediction & Estimation of Reliability on the Traction Motor - Dielectric loss and PD Properties according to High Voltage (견인전동기의 고강예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 고전압 인가에 따른 유전손실 및 부분방전 특성 연구)

  • Wang, Jong-Bae;Baek, Jong-Hyen;Byun, Yoon-Sub;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1371-1373
    • /
    • 2000
  • In this paper, the complex accelerating degradation of traction motor driven with VVVF controlled inverter were performed on the form coil samples with the 200 Class insulation system. in order to evaluate the reliability and the long-term life. After aging, the dielectric and PD properties were investigated on the 10 cycles aging sample in the range of $20{\sim}160[^{\circ}C]$ and AC $250{\sim}2250[V]$ to diagnosis the condition of end-life and find the dominative factors of degradation.

  • PDF

Maximum Efficiency Drive of Vector-Controlled Induction Motors (벡터제어 유도전동기의 최대효율 운전)

  • Yoon, Duck-Yong;Choe, Gyu-Ha;Hong, Soon-Chan;Baek, Soo-Hyun;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.27-37
    • /
    • 1996
  • This paper proposes the control algorithm for maximum efficiency drive of PWM inverter - induction motor system with high dynamic performance. If the induction motor is driven under light load with rated magnetizing current, the Iron loss is excessively large compared with the codder loss which results in doer motor efficiency. Maximum efficiency drive of an induction motor can be achieved by controlling the magnetizing current to satisfy the optimal ratio that leads the total motor loss to be a minimum value at a given speed. The proposed control algorithm essentially uses vector control technique and adopts voltage decoupling control strategy to prevent the degradation of dynamic performance due to reduced magnetizing current. To verify the proposed method, digital simulations and experiments are carried out for a squirrel-cage induction motor with the rating of 2.2[kW].

  • PDF

Development of Interior type Permanent Magnet Synchronous Motor for Electric Golf Car (전동 골프카 구동용 매입형 영구자석 동기전동기 개발)

  • Oh, Young-Jin;Ryu, Sung-Lay;Kim, Ji-Hyun;Lee, In-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1025-1026
    • /
    • 2007
  • Recently study on components for a electric golf car and a utility car driven by a electric motor has been performed actively, and the study on a drive motor, a inverter and a battery focuses on a small, light weight and high power density source to improve fuel efficiency using limited electric energy. Especially, since a utility car such as a golf car performance depends on initial acceleration and maximum speed capability, a drive system requires high power and large and wide operation area, This study therefore investigates on the interior permanent magnet synchronous motor with high power density and wide operation, and is verified with the test result after design and characteristic analysis is performed

  • PDF

The study of isolation driver for Reversible Power Converter (가역전력변환기 구동의 절연에 관한 연구)

  • Chun, J.H.;Lee, H.W.;Taniguchi, Hatsunori
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1349-1351
    • /
    • 2005
  • In this paper discusses isolation driver of single phase AC-DC reversible power converter The reversible power converter driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality with out filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/BC-AC multi-level reversible converter.

  • PDF

System Fault Analysis of Inverter Fed Induction Motor drives (인버터 구동 유도전동기의 계통사고 해석)

  • Kwon Young Mok;Kim Jae Chul;Song Seung Yeop;Shin Joong Eun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.304-306
    • /
    • 2004
  • Recently, operating equipment with the high quality is necessary as technology is developing rapidly and equipment becomes more accurate. Therefore, the importance of diagnosis has been rising in modem industries. This paper presents that the induction motor is driven by invertor. We were using EMTP (Electromagnetic Transient Program) to study different characteristics of induction motor caused by faults; single phasing and the short circuit fault. After having the fault occurred in feeder cable, motor current, flux and torque waveform are analyzed

  • PDF

A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train (한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구)

  • 이상우;김근웅;윤종학;한성수
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

Torsional Vibration Phenomenon due to Pulse Torque of Variable Speed Induction Motor on Rotating Systems (가변 속도 유도 전동기에서 발생한 펄스 토크에 의한 회전축계의 비틀림진동 현상)

  • Lee, Donchool;Vuong, QuangDao;Nam, Taekkun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.414-419
    • /
    • 2015
  • Recently, commercial ships and other specialized vessels with electric propulsion system employ variable speed induction motor as its prime mover. The wide application of electrical motors also includes being the main drive system in most industrial machineries. However, during its start-up, shutdown, and brake switch operation, excessive torque variation are generated. As such, flexible coupling are installed in order to reduce the transmitted torque fluctuation to the driven side. In this paper, the pulse torque generated by an variable speed induction motor was analyzed theoretically and through measurement of torsional vibration. Induction motor with inverter on marine propulsion system and industrial compressor were used as experimental subjects. The study confirmed that pulse torque are generated regardless of motor speed and interpreted as a vibration source of the whole system. Results presented herein can be adopted as the basis in future amendment of inspection classifying body regulations.

Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve (전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究))

  • Choi, S.O.;Kim, J.H.;Yang, H.S.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.

  • PDF