• 제목/요약/키워드: Inverter built-in

검색결과 107건 처리시간 0.019초

Direct Power Control without Current Sensors for Nine-Switch Inverters

  • Pan, Lei;Zhang, Junru;Wang, Kai;Wang, Beibei;Pang, Yi;Zhu, Lin
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, the nine-switch inverter has been proposed as a dual output inverter. To date, studies on the control strategies for NSIs have been mostly combined with their application. However, in this paper, a mathematical model and control strategy for nine-switch inverters has been proposed in view of the topology. A switching function model and equivalent circuit model of a nine-switch inverter have been built in ${\alpha}{\beta}$ coordinates. Then, a novel current observer with an improved integrator is proposed based on the switching function model, and a direct power control strategy is proposed. No current sensors are used in the proposed strategy, and only two voltage sensors are employed. The performance of the proposed control method is verified by simulation and experimental results.

LLC 공진형 인버터를 이용한 IPT 전력전송 효율 특성 분석 (Characteristic Analysis of The Efficiency of the Power Transfer of the IPT Using LLC Resonant Inverter)

  • 김기병;이형우;박찬배;이병송;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.401-408
    • /
    • 2011
  • Nowadays, the development of sustainable transportation has been researched all over the world and Korea Railroad Research Institute (KRRI) is conducting a study in order to apply the sustainable Contactless Inductive Power Supply Technology to the electric railway system. But, inherent large flux leakage has limited the high power transmission because the gap of the Inductive Power Transformer(IPT) is much larger than one of the conventional transformers. In this study, a method to compensate the leakage flux and improve the power transmission by using LLC resonant inverter was proposed, incorporated in a built system, and verified by experimental work.

  • PDF

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

Design Considerations for Low Voltage Claw Pole Type Integrated Starter Generator (ISG) Systems

  • Lee, Geun-Ho;Choi, Geo-Seung;Choi, Woong-Chul
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.527-532
    • /
    • 2011
  • Due to the need for improved fuel consumption and the trend towards increasing the electrical content in automobiles, integrated starter generator (ISG) systems are being considered by the automotive industry. In this paper, in order to change the conventional generator of a vehicle, a belt driven integrated starter generator is considered. The overall ISG system, the design considerations for the claw pole type AC electric machine and a low voltage very high current power stage implementation are discussed. Test data on the low voltage claw pole type machine is presented, and a large current voltage source DC/AC inverter suitable for low voltage integrated starter generator operation is also presented. A metal based PCB (Printed Circuit Board) power unit to attach the 4-parallel MOS-FETs is used to achieve extremely high current capability. Furthermore, issues related to the torque assistance during vehicle acceleration and the generation/regeneration characteristics are discussed. A prototype with the capability of up to 1000 A and 27 V is designed and built to validate the kilo-amp inverter.

Analysis and Implementation of PS-PWAM Technique for Quasi Z-Source Multilevel Inverter

  • Seyezhai, R.;Umarani, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.688-698
    • /
    • 2018
  • Quasi Z-Source Multilevel Inverter (QZMLI) topology has attracted grid connected Photovoltaic (PV) systems in recent days. So there is a remarkable research thrust in switching techniques and control strategies of QZMLI. This paper presents the mathematical analysis of Phase shift- Pulse Width Amplitude Modulation (PS-PWAM) for QZMLI and emphasizes on the advantages of the technique. The proposed technique uses the maximum and minimum envelopes of the reference waves for generation of pulses and proportion of it to generate shoot-through pulses. Hence, it results in maximum utilization of input voltage, lesser switching loss, reduced Total Harmonic Distortion (THD) of the output voltage, reduced inductor current ripple and capacitor voltage ripple. Due to these qualities, the QZMLI with PS-PWAM emerges to be the best suitable for PV based grid connected applications compared to Phase shift-Pulse Width Modulation (PS-PWM). The detailed math analysis of the proposed technique has been disclosed. Simulation has been performed for the proposed technique using MATLAB/Simulink. A prototype has been built to validate the results for which the pulses were generated using FPGA /SPARTAN 3E.

IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포특성 (Distribution Characteristics of Irregular Voltage in Stator Windings of IGBT PWM Inverter-Fed Induction Motors)

  • 황돈하;김용주;이인우;배성우;김동희;노체균
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.351-358
    • /
    • 2003
  • 본 논문에서는 IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 스위칭 써지전압 분포특성을 분석하였다. 고정자 권선의 턴 및 코일간의 전압분포를 해석하기 위하여 케이블을 포함한 유도전동기의 등가모델을 제안하고, 유한요소법을 이용하여 고주파 파라메타를 산출하였다 또한, 유도전동기, IGBT PWM 인버터 및 케이블등에 대한 전체 시스템의 EMTP 시뮬레이션을 통하여 인버터 상승시간, 케이블 길이 및 스위칭 주파수 등의 영향에 따른 전압분포를 분석하였다. 380[V], 50[HP] 유도전동기 고정자 권선을 대상으로 한 전압분포 특성실험을 통하여 인버터용 전동기 설치 및 과전압 억제용 필터 설계시의 유용한 자료를 제시하였다.

중국 티베트지역의 100kWp급 태양광발전시스템 실증연구 (Installation and Performance Evaluation of 100kWp PV System in Tibet)

  • 김석기;윤재호;이정철;안세진;윤경훈;송진수
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.16-22
    • /
    • 2006
  • This paper present the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea.

  • PDF

Switching-Mode BJT Driver for Self-Oscillated Push-Pull Inverters

  • Borekci, Selim;Oncu, Selim
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.242-248
    • /
    • 2012
  • Self oscillating current fed push pull resonant inverters can be controlled without using special drivers. Dc current flows through the choke coil and the power switches, although the driving signals of the power switches are sinusoidal. When the base current is near zero, the transistors cannot be operated in switching mode. Hence higher switching power losses and instantaneous peak power during off transitions are observed. In this study, an alternative design has been proposed to overcome this problem. A prototype circuit has been built which provides dc bias current to the base of the transistors. Experimental results are compared with theoretical calculations to demonstrate the validity of the design. The proposed design decreases the peak and average power losses by about 8 times, when compared to conventional designs.

New MPPT Control Strategy for Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Bae, Hyun-Su;Park, Joung-Hu;Cho, Bo-Hyung;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.174-180
    • /
    • 2007
  • In this paper, a simple control method for two-stage utility grid-connected photovoltaic power conditioning systems (PCS) is proposed. This approach enables maximum power point (MPP) tracking control with post-stage inverter current information instead of calculating solar array power, which significantly simplifies the controller and the sensor. Furthermore, there is no feedback loop in the pre-stage converter to control the solar array voltage or current because the MPP tracker drives the converter switch duty cycle. This simple PCS control strategy can reduce the cost and size, and can be utilized with a low cost digital processor. For verification of the proposed control strategy, a 2.5kW two-stage photovoltaic grid-connected PCS hardware which consists of a boost converter cascaded with a single-phase inverter was built and tested.

중국 티베트지역의 100kWp급 태양광발전시스템 실증연구 (Installation and Performance Evaluation of 100kWp PV System in Tibet)

  • 김석기;윤재호;이정철;안세진;윤경훈;송진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.125-129
    • /
    • 2006
  • This paper presents the isolation and performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module by using Koreans solar cells, constructed site and built control house.

  • PDF