A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

치과용 초소형 X-선 튜브의 선량평가 (Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging)

  • 지윤서;김연우;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.160-167
    • /
    • 2015
  • 의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다.

국내 치과방사선의 현황 및 이용 실태 (The Actual State and the Utilization for Dental Radiography in Korea)

  • 신귀순;김유현;이보람;김세영;이귀원;박창서;박혁;장계용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 치과 X선 검사 시 환자선량의 권고량 가이드라인을 개발하기 위해서 우선 국내 치과방사 선의 현황 및 이용 실태를 설문조사하여 비교분석하였다. 응답을 받은 77곳의 치과병 의원 중에서 치과대학이 있는 치과대학병원을 A그룹(11곳), 치과대학이 없는 대학병원을 포함한 치과병원을 B그룹(30곳), 치과의원을 C그룹(36곳)으로 분류하였다. 그룹별로 분석한 결과는 다음과 같았다. 치과병 의원 한 곳당 평균 unit chairs수는 A그룹 140.2개, B그룹 15.3개, C그룹 5.8개, 평균치과의사수는 A그룹 112.6명, B그룹 7.3명, C그룹 1.7명, 평균방사선사수는 A그룹 3.1명, B그룹 0.5명, C그룹에는 한 명도 없었고, 평균치과위생사수는 A그룹 19.7명, B그룹 12.5명, C그룹 3.3명이었다. 설치된 치과용 X선장치의 평균보유수는 A그룹 14.64대, B그룹 3.21대, C그룹 2.19대로 나타났다. 이 중에서 구내촬영장치가 가장 많았고, 다음은 파노라마 장치, 세팔로 장치, CBCT 장치 순이었으며, 장치시스템의 비율은 세 그룹 모두 DR 시스템이 50% 이상으로 가장 많았다. 필름 시스템인 경우, 사용된 구내필름은 감광도가 높은 Insight 필름(Kodak, USA)이 대부분이었으며, 자동 현상기는 사용하는 곳이 적었으나, 필름유지기구는 사용하는 곳이 약간 많았다. PACS 이용률은 A그룹 90.9%, B그룹 83.3%, C그룹 16.7%이었고, 프로그램은 국내의 Infinitt에서 개발된 PiView STAR가 가장 많이 이용되고 있었다. 치과병 의원 한 곳당 2008년도의 연간 평균촬영건수는 A그룹이 B그룹보다 6.8배, C그룹보다 21.2배 더 많았으며, 구내 치근단 촬영과 파노라마 촬영이 대부분이었다. 구내 치근단 촬영 시 관전압과 관전류는 세 그룹 모두 비슷하였으나, 노출시간은 C그룹이 A그룹의 12배, B 그룹의 3.5배 정도 길었다. 즉, 대부분 치과위생사가 촬영하고 있는 C그룹에서는 방사선 노출량이 다른 그룹에 비해 훨씬 많았다. 그러나 파노라마촬영 시의 조건은 세 그룹에서 큰 차이가 없었다. 결론적으로, 촬영조건은 경험적 지식을 따르기보다는 권장량을 사용해야 하며, 필름시스템에서는 자동현상기와 필름유지기구를 사용하여 방사선의 노출량을 줄여준다. 또한 환자선량의 감소와 X선 영상의 질 향상을위해서 X선발생장치 및 관련기기의 체계적인 정도관리가 반드시 필요하다.