• Title/Summary/Keyword: Intraoral pH

Search Result 24, Processing Time 0.022 seconds

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Chemical burns of the oral mucosa caused by Policresulen: report of a case (Policresulen 오용에 의한 구강 궤양의 발병 증례 및 화학화상에 대한 고찰)

  • Jung, Jung-Woo;Byun, Jin-Seok;Jung, Jae-Kwang;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.109-114
    • /
    • 2013
  • Chemical burn on the oral mucosa is caused by contact with various chemical products and manifests with localized mucositis, keratotic white lesions, bleeding, and painful tissue surface due to the coagulation of the tissue. Policresulen ($Albothyl^{(R)}$) is a topical antiseptic, commonly used over-the-counter drug for vaginitis, thrush and stomatitis. This drug is highly acidic with pH 0.6, and can act as a strong corrosive agent to oral mucosa. When inadvertently used in oral cavity, it may cause chemical burns of oral mucosa, resulting necrosis and bleeding surface resembling to erythema multifome. A 56 years old female patient presented with the chief complaints of painful ulcerations on the tongue, the upper and lower lips. On intraoral examination, an erythromatous, erosive or ulcerative surface covered with inflammatory exudates or bleeding crust is observed on the anterior half of the tongue and the upper and lower lips. She has occasionally applied the policresulen solution topically on the tongue to relieve pain from recurrent focal glossitis for about 10 years. In this time she applied it broadly and repeatedly to the tongue, the upper and lower lips for the purpose of pain relief by herself without instruction by physician or dentist. After cessation of policresulen application, the oral mucosa was rapidly recovered with use of topical steroids. In 2 weeks the lesions subsided completely. In summary, inadvertent use of $Albothyl^{(R)}$ on oral mucosa may result in chemical burn, causing mucosal erosion, ulceration and inflammation. It can be recovered by topical use of corticosteroid for 2 weeks after cessation of using $Albothyl^{(R)}$.

A STUDY ON PROFILE CHANGE OF SKELETAL CLASS III MALOCCLUSION PATIENTS AFTER WEARING PROTRACTION HEAD GEAR (골격성 제III급 부정교합 환자에서 상악골 전방견인장치 사용후 측모 변화에 대한 연구)

  • Lim, Joong-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.375-401
    • /
    • 1995
  • Cause of skeletal Class III malocclusion in growing patients can be classified into maxillary deficiency, mandibular overgrowth, and combination of the two. Use of Protraction Head Gear(P.H.G.) has been recommended for treatment of growing Class III malocclusion patients, for it results in forward & downward movement of maxilla and backward & downward rotation of mandible. Numerous animal experiments were performed and clinical study data have been reported ; nevertheless, studies on soft tissue profile change and comparison of treatment effects among the patients who had undergone treatment are considered to be somewhat insufficient. The author selected 93 patients, who had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with P.H.G. ; the sample group was divided according to sex, treatment beginning age, palatal suture opening(intraoral appliance), and facial growth pattern. For each group, changing patterns of hard and soft tissue profile observed, and comparision with 20 normal group(Angle's Class I) patients of statistical significance in amount of growth and treatment of hard and soft tissue was done. The following results were obtained. 1. Skeletal, dental, and soft tissue measurements indicated that more growth changes was induced in the sample group that used P.H.G. compared to the growth amount of normal group. 2. No statistical significance was observed in the amounts of maxillary forward movement and mandibular backward & downward rotation depending on treatment beginning age in both sex group. 3. R.P.E. showed more significant maxillary forward movement and less protrusion of upper incisor than La-Li. 4. There was no statistical significance in the amount of maxillary forward movement depending on facial growth pattern. On the other hand, measurements indicating mandibular downward & backward rotation indicated greater change in counterclockwise growth pattern group than the clockwise. 5. Changes in upper and lower lip thicknesses showed a close relationship with positional changes in underlying bone tissue and upper and lower teeth, and upper lip height and nasolabial angle increased and mentolabial angle decreased.

  • PDF

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.