• Title/Summary/Keyword: Intramedullary Fixation Nail

Search Result 23, Processing Time 0.024 seconds

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Do the Rotating Hinge-Flexible Intramedullary Nail Composites Alleviate Junctional Osteolysis in Megaprothesis Reconstruction for Bone Tumor? (탄력성 있는 골수강 내고정물과 회전경첩형 슬관절 전치환물을 조합한 종양인공관절로 자가골의 골 용해를 감소시킬 수 있는가?)

  • Song, Won-Seok;Cho, Wan-Hyeong;Cho, Sang-Hyun;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.2
    • /
    • pp.96-104
    • /
    • 2007
  • Purpose: The authors investigated whether 35 flexible nail-rotating hinge composite reconstructions around knee joint minimize junctional osteolysis of host bone. Material and Method: The reconstructive technique was as follows: 1) en bloc tumor resection, 2) filling of the host bone marrow cavity with multiple Ender nails, 3) assembling the Ender nails and an Endo-Link type total knee component with wire and bone cement. Result: Mean follow-up was 53 months (ranged 30~79). At final follow-up, 29 patients retained a mobile joint. Resection of more than 40% of bone showed a positive relationship with junctional hypertrophy (p=0.028). Eight patients showed nail breakage and eight prostheses were removed due to early or late infection. The cumulative prosthetic survival rate was 33% at 6 year. Average functional score according to the MSTS criteria was 26.8. Conclusion: Mid-term evaluations showed that results were fair. The revision process was straightforward. Junctional hypertrophy observed appears to give some clues as to how to minimize osteolysis at the prosthesis-host junction after modular prosthesis fixation.

  • PDF