Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Single Center Experience of the Balloon-Stent Technique for the Treatment of Unruptured Distal Internal Carotid Artery Aneurysms: Sharing a Simple and Reliable Tip to Use Scepter-Atlas Combination (원위내경동맥에 위치한 비파열성 동맥류의 치료에 있어 풍선-스텐트 테크닉에 대한 단일기관의 경험: Scepter-Atlas 조합을 사용하기 위한 간단하지만 확실한 방법)

  • Yu-jung Park;Jieun Roh;Seung Kug Baik;Jeong A Yeom;Chul-Hoo Kang;Hee Seok Jeong;Sang Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1258-1273
    • /
    • 2021
  • Purpose The balloon-stent technique (BST) has certain strengths as an assisted technique for the treatment of complex aneurysms. After Atlas release, the BST can be executed without an exchange maneuver of the balloon to the stent-delivery catheter. The purpose of this article is to share our experience with the BST using the Scepter-Atlas combination. Materials and Methods Device inspection led us to a simple method to avoid failure in loading Atlas to the Scepter. From March 2018 to December 2019, 57 unruptured distal internal carotid artery (dICA) aneurysms were treated with coil embolization; among which, 25 aneurysms in 23 patients were treated with BST. Clinical and angiographic data were retrospectively collected and reviewed. Results The technical success rate of the Scepter-Atlas combination increased from 50% to 100% after careful inspection. BST angiographic results were comparable to the stent-assisted coil (SAC) group treated during the immediately post-embolization same period (modified Raymond-Roy classification [MRRC] 1 & 2 84% in BST, 96.3% in SAC) and during short-term follow-up (MRRC 1 & 2 95.8% in BST, 88.4% in SAC). A small number of patients showed periprocedural complications, but none had clinical consequences. Conclusion BST using the Scepter-Atlas combination can provide an effective and safe method for the treatment of dICA aneurysms. Scepters can be used as delivery catheters for Atlas.

The Effect of External Radiation Therapy for Intracrania1 Arteriovenous Malformation - Conventional Radiation Therapy vs Stereotactic Radiosurgery - (뇌동정맥성 기형의 외부방사선 치료 효과)

  • Kim In Ah;Jang Hong Suk;You Mi Ryung;Yoon Sei Chul;Kim Moon Chan;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 1991
  • From February 1987 through July 1990, the seventeen cases of inoperable intracranial arteriovenous malformation (AVM) were treated using 6 MV linear accelerator at the Division of Therapautic Radiology, Kang Nam 51. Mary's Hospital. Of seventeen cases, fourteen were male and three were female. Ages ranged from 10 to 51 years (median age of 25 years). The main symtoms were headache, epilepsy and hemiparesis in decreasing order of frequency. The middle cerebral artery is the most common origin of the feeding vessel $(41.2\%)$. Four were treated by conventionally fractionated radiation therapy (CRT, thirteen were treated by stereotactic radiosurgery (RS). duration or follow-up in CRT and RS group were 4 to 43 months (median 33 months) and 3 to 12 months (median 13 months), respectively. When the response was assessed by radiologic follow-up study, two of four CRT group showed minimal response. Of thirteen cases of RS group, two $(15.4\%)$ showed complete response, five $(38\%)$ partial response, two $(15.4\%)$ minimal response and four $(30.7\%)$ no response by the same assessment. There was no statistical significance in terms of follow-up period (p=0.22), size of lesion (p=0.82) and treated dose (p=0.05). Further accumulation of experience is recommended with proper case selection and sufficient follow-up period.

  • PDF

The Clinical Experience of the Aortic Arch Replacement in Acute Type A Aortic Dissection (급성대동맥박리증에서 궁치환술의 임상 경험)

  • 조광조;우종수;성시찬;김시호;이길수
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.335-342
    • /
    • 2003
  • Background: The aortic arch replacement in an acute aortic dissection is technically demanding procedure that has a lot of postoperative morbidity and high mortality The authors have applied several techniques of aortic arch replacement to overcome the risks of the procedure. Therefore we analysed the results of these techniques. Material and Method: From March of 1996 to July of 2002, we performed 31 cases of the aortic arch replacement in the Stanford type A acute aortic dissection. There were 12 male and 19 female patient's with 59.6$\pm$9.4 years of mean age. Among them 18 cases were treated with the hemiarch replacement and 13 cases with the total arch replacement. We approached the aortic arch through median sternotomy in all but 3 cases of Clamshell incision and applied the deep hypothermic circulatory arrest with retrograde cerebral perfusion. The associated procedures were 2 Bentall's procedures, an axillobifemoral bypass, a femorofemoral bypass and a carotid artery bypass. Result: The postoperative morbidities were 8 acute renal failures, 3 CNS complications, 2 low cardiac output syndromes, 2 malpefusion syndromes, and 2 deep wound infections. There were 4 cases of early hospital mortality which were from an acute renal failure a postoperative bleeding, a low cardiac output syndrome, and a reperfusion syndrome. There were 3 cases of late hospital mortality which were from an acute renal failure, and 2 multiorgan failures. So the total mortality rate was 22.5%. There were 4 cases of late mortality after the discharge, which were form 2 cases of distal anastomotic rupture and 2 cases of intracranial hemorrhage. Conclusion: The hemiarch replacement has relatively shorter operative time and lower hospital mortality but higher late mortality than the total arch replacement. The total arch replacement needs more technically demanding procedure.