• Title/Summary/Keyword: Intracavitary

Search Result 154, Processing Time 0.022 seconds

Coronary Artery Bypass Graft (CABG) for Intracavitary Coronary Artery Disease - A case report- (심강내관상동맥(Intracavitary Coronary Artery)질환에 대한 관상동맥우회술 -수술치험 1예-)

  • Kim Su-Wan;Sung Kiick;Park Pyo Won;Jun Tae-Gook;Park Kay-Hyun;Lee Young Tak
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.504-506
    • /
    • 2005
  • Intracavitary coronary artery is variant anomalous entrance to right ventricular cavity of left anterior descending artery. Since the disease is extremely rare, there has not been any report of it in Korea and is only found in $0.2\~0.3\%$ of all CABG patients. It is very difficult to be diagnosed by preoperative coronary arteriography (CAG) and secure suture is needed for right ventriculotomy after CABG due to bleeding from right ventricle. Horizontal mattress suture with pledget has been recommended but, it could compress the myocardium surrounding ventriculotomy and result in disturbed flow of left anterior descending artery branch and perforating artery. So we used simple interrupted suture and the patient was recovered as other CABG patients without complications.

A Case of Right Atrial Mass Associated with Hepatocellular Carcinoma (간세포암에 동반된 우심방 종괴 1례)

  • Park, Chan-Won;Choi, Jin-Soo;Kwon, Soon-Uk;Song, Young-Doo;Kim, Jun-Hwan;Lee, Heun-Joo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.1
    • /
    • pp.119-124
    • /
    • 1999
  • Right atrial metastasis occurs in 1 to 4% of patients with hepatoma, and the extension to intracavitary or metastasis of a tumor as a large mass rare. However, the high risk of progressive heart failure and sudden death from the tricuspid valve obstruction necessitates prompt diagnosis of intracavitary extension, and adequate intervention is needed to prolong a patient's life. A 49 year-old female was referred to our hospital for further evaluation of a liver mass, which was identified at a local clinic. The liver mass was confirmed as hepatocellular carcinoma with CT and celiac angiographies findings. She was treated with transarterial chemoembolization. Thirty-four months after discharge, a low density right atrial mass was noted incidentally with chest computed tomography while investigating a massive right pleural effusion for possible pulmonary metastasis. Echocardiography showed a huge inhomogenous echogenic mass at the right atrium. The present report describes a case of primary hepatocellular carcinoma with a intracavitary cardiac mass detected with two dimensional echocardiography.

  • PDF

Comparison of Clinical Efficacy of Three Different Neoadjuvant Approaches (Chemotherapy Combined Vaginal Intracavitary Irradiation, Neoadjuvant Chemotherapy Alone or Radiotherapy) Combined with Surgery for Patients with Stage Ib2 and IIa2 Cervical Cancer

  • Fu, Jian-Hong;Gao, Zhan;Ren, Chen-Chen;Shi, Yong-Gang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2377-2381
    • /
    • 2013
  • A total of 285 patients with stage Ib2 and IIa2 cervical cancer were categorized into three groups, and received preoperative neoadjuvant chemotherapy combined with vaginal intracavitary irradiation, neoadjuvant chemotherapy alone or radiotherapy, respectively. The effective rate of 70.6 % in group 1 was much higher than 41.4% in group 2 (P=0.000) and 46.9 % in group 3 (P=0.000); The percentage of patients receiving postoperative adjuvant therapy was 44.1% in group 1, much lower than 67.8% in group 2 (P=0.001) and 64.6% in group 3 (P=0.004); The percentage of patients with no postoperative risk factor in group 1 was 52.0%, much higher than 32.2% in group 2 (P=0.006) and 35.4% in group 3 (P=0.019); The occurrence rate of surgery-related complications in groups 1, 2 and 3 were 29.4%, 28.7%, and 33.3%, respectively, with no statistical differences among the groups (P=0.981). Regarding preoperative neoadjuvant complications, none were obvious in group 3, while occurrence rates of myelosuppression in groups 1 and 2 were 89.1% and 86.6%, of nausea and vomitting were 78.4% and 78.2%, but without significant differences (all P>0.05). Among 166 patients who received postoperative adjuvant therapy in the three groups, the occurrence rates were: 65.4%, 64.3% and 61.1% respectively for myelosuppression; 42.3%, 38.1%, and 38.9% for nausea and vomiting; 9.6%, 9.5% and 9.7% for urocystitis; and 63.5%, 69.0% and 65.3% enteritis and rectitis. There were no statistically significant differences among them (all P>0.05). The five-year disease-free survival rates (DFS) in groups 1, 2, 3 were 78.3%, 75.1%, 80.9%, respectively; the five-year overall survival rates (OS) were 81.4%, 78.2%, and 81.1%, respectively. The five-year OS of 166 patients receiving postoperative in the three groups were 72.4%, 69.5%, and 71.8%, respectively, with no significant variation (all P>0.05). Although there were no differences among three groups in DFS and OS, preoperative neoadjuvant chemotherapy combined with intracavitary radiotherapy may increase the effective rate and the percentage of patients with no postoperative risk factors and decrease the percentage of patients receiving postoperative adjuvant therapy, thereby decreasing complications indirectly and increasing quality of life.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.

Rectal Injuries after Radiotherapy for Carcinoma of the Uterine Cervix (자궁경암(子宮頸癌) 방사선치료(放射線治療)에 의한 직장손상(直腸損傷))

  • Kim, Jung Jin
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.103-109
    • /
    • 1983
  • 47 out of 56 cases of intact uterine cervix cancer treated by radiation at the Hanyang University Hospital were followed 18 months or more after treatment. (7 patients died before 18 months, 2 cases lost to follow-up). Age distribution reveal 5 cases in 30's, 18 cases in 40's, 17 cases in 50's, 7 cases in 60's. Histologically, all cases were squamous cell type except one case of adenocarcinoma. 1. 45 cases were treated by combined external Co-60 irradiation and intracavitary irradiation by Cs-137 small sources. 1 case was treated by external irradiation only, and 1 case by intracavitary only. 2. Rectal injuries were observed in 13 cased (27.6%), 4 cases in Grade 1, 8 cased in Grade 2 and 1 cases in Grade 3 which needed surgical management. 3. Average intervals of rectal injury following treatment was 9.2 months varying from 5 to 15 months. 4. Relation between rectal injury and point A dose reveal 6 cases between 7000-7999 rad and 6 cases between 8000-8999 rad and 1 case above 9000 rad. Even though there is no direct relation between point A dose and rectal injury, it is expected that rectal injury increases as point A dose increase. 5. In the normal condition, rectal injury can't be attributed to one major cause. Radiation dose, small source distribution, general condition of patients, local anatomy of the individual patient, history of PID and previous surgery, all play complex roles.

  • PDF

The evaluation of absorbed dose of rectum for the patient of intracavitary treatment $^{60}$ Co by MgB$_4$O$_{7}$ (Mn) TLD (MgB$_4$O$_{7}$ (Mn) TLD에 의한 $^{60}$ Co 강내 치료 환자의 직장의 흡수선량 평가)

  • 유명진;신병철;문창우;정태식;염하용;도시홍
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.21-26
    • /
    • 1994
  • By measuring with TLD, absorbed dose of rectum will be determined more accurately than calculated value. MgB$_4$O$\sub$7/(Mn) TLD phosphor was prepared and its characteristic was studied. To measure the absorbed dose of rectum with TLD, 33 patients who had intracavitary treatment with $\^$60/Co from April 1994 to September 1994 at Kosin Medical center. There were 10-59% differecne in most cases between the calculation and the measurement for the absorbed dose of rectum. The difference was less the case with tandem and ovoid than the case with only ovoid.

  • PDF

Treatment of Carcinoma of the Uterine Cervix with High-Dose-Rate Intracavitary Irradiation using Ralstron (고선량률 강내조사를 사용한 자궁경부암의 치료)

  • Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.231-239
    • /
    • 1990
  • From May 1979 through December 1981 a total of 524 patients with carcinoma of the uterine cervix were treated by radiation therapy with curative intent. Among the 524 patients, 350 were treated with a high-dose-rate (HDR), remote-controlled, afterloading intracavitary irradiation (ICR) system using a cobalt source (Ralstron), and 168 patients received a low-dose-rate (LDR) ICR using a radium source. External beam irradiation with a total dose of 40-50 Gy to the whole pelvis followed by intracavitary irradiation with a total dose of 30-39 Gy in 10-13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rates in the HDR-ICR group were $77.6{\%}$ in stage IB (N=20), $68.2{\%}$ in stage II (N=182), and $50.9{\%}$ in stage III (N=148). In LDR-ICR group, 5-year survival rates were $87.5{\%}$ in stage IB (N=22), $66.3{\%}$ in stage II (N=91), and $55.4{\%}$ in stage III (N=52). Survival rates showed a statistically significant difference by stage, but there was no significant difference between the two ICR groups. Late bowel complications after radiotherapy were noted in $3.7{\%}$ of the HDR-ICR group and $8.4{\%}$ of the LDR-ICR group. There was no severe complication requiring surgical management. The incidence of bladder complications was $1.4{\%}$ in the HDR-ICR group and $2.4{\%}$ in the LDR-ICR group. The application of HDR-ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually nil in contrast to that of LDR-ICR. Within a given period of time, more patients can be treated with HDR-ICR because of the short treatment time. Therefore, the HDR-ICR system is highly recommended for a cancer center, particularly one with a large number of patients to be treated. In order to achieve an improved outcome, however, the optimum dose-fractionation schedule of HDR-ICR and optimum combination of intracavitary irradiation with external beam irradiation should be determined through an extensive protocol.

  • PDF

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Fabrication and Evaluation of Mercury(II) Iodide Unit Cell Dosimeter to Confirm the Feasibility of Digital Quality Assurance in Intracavitary Radiotherapy (방사선 근접치료의 디지털 정도관리 가능성 확인을 위한 HgI2 Unit Cell 선량계의 제작 및 평가)

  • Jung, Jae-Hoon;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.257-263
    • /
    • 2022
  • In intracavitary radiotherapy, it is essential to verify the correct location of radiation source among quality control items because an incorrect location will irradiate an unnecessary dose to normal tissues. As a basic study of digital line dosimeters, this study fabricated a unit cell dosimeter based on polycrystalline mercury (II) iodide (HgI2) and compared its performance with a diode. The study result showed that for reproducibility, the relative standard deviation (RSD) was 1.21%, satisfying the RSD evaluation criterion of within 1.5%. Considering linearity, the coefficient of determination R2 showed an excellent result of 0.9997. Regarding the evaluation of distance dependence, it showed a similar trend in general with a difference of 0.035 cm for intensity 50% when compared with the inverse square value. This study suggests the applicability of a digital dosimeter for brachytherapy quality control by evaluating the performance of the HgI2 dosimeter. This study on dosimeter for candidate photoconductor materials can be used as basic data in all areas using radiation.