• Title/Summary/Keyword: Intra-view

Search Result 89, Processing Time 0.021 seconds

Differences of 1-2 Intermetatarsal Angle between Intra-operative nonweight-bearing and Postoperative weight-bearing in Proximal Metatarsal Osteotomy for Hallux Valgus (무지 외반증의 근위 중족골 절골술에 있어서 수술 중 비체중부하와 수술 후 제중부하 방사선 소견에서의 제 1-2 종족골간 각의 차이)

  • Sung, Il-Hoon;Kim, Joo-Hak;Whang, Khun-Sung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2003
  • Purpose: To study the relationship of the 1st to 2nd intermetatarsal angle(1-2 IMA) between the intra-operative and weight bearing postoperative anterior-posterior(AP) radiography, and evaluate the intra-operative predictability for the postoperative 1-2 IMA after proximal metatarsal osteotomy(PMO) in the hallux valgus deformity. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. After the oblique PMO(Ludloff procedure) was performed and the osteotomy site was fixed temporarily, the AP view was taken intra-operatively. About 10 weeks after surgery, postoperative weight bearing AP view was taken. The pre -. intra -, and postoperative 1-2 IMAs were compared and ana lysed statistically. Results: The 1-2 IMAs of the weight bearing preoperative, non-weight bearing intra-operative and weight bearing postoperative AP view were $15.9^{\circ}{\pm}1.8^{\circ},\;4.7^{\circ}{\pm}2.1^{\circ}$, and $6.8^{\circ}{\pm}2.5^{\circ}$ (Mean${\pm}$SD) respectively. The postoperative 1-2 IMA was greater than intra-operative measurement by $2.1^{\circ}{\pm}1.8^{\circ}$ (range; $-1^{\circ}$ to $6^{\circ}$) which was stastistically significant(p<0.05). To get less than $9^{\circ}$ postoperatively as an average normal, intra-operative 1-2 IMA should be within $3.8^{\circ}$ to $5.2^{\circ}$ (95% confidence interval), and intra-operative 1-2 IMA should be within $3.4^{\circ}{\pm}$to $5.4^{\circ}$(95% confidence interval) to get more than $6^{\circ}$ difference between preoperative and postoperative 1-2 IMA, which is regarded as more than average correction by the distal metatarsal osteotomy. Conclusion: In hallux valgus surgery, it should be considered that intra-operative 1-2 IMA was less than the postoperative. To achieve postoperative 1-2 IMA less than $9^{\circ}$ and more than correction angle of $6^{\circ}$, it is suggested that the intra-operative 1-2 IMA should be measured less than about $5^{\circ}$.

  • PDF

Screen Content Coding Analysis to Improve Coding Efficiency for Immersive Video (몰입형 비디오 압축을 위한 스크린 콘텐츠 코딩 성능 분석)

  • Lee, Soonbin;Jeong, Jong-Beom;Kim, Inae;Lee, Sangsoon;Ryu, Eun-Seok
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.911-921
    • /
    • 2020
  • Recently, MPEG-I (Immersive) has been exploring compression performance through standardization projects for immersive video. The MPEG Immersion Video (MIV) standard technology is intended to provide limited 6DoF based on depth map-based image rendering (DIBR). MIV is a model that processes the Basic View and the residual information into an Additional View, which is a collection of patches. Atlases have the unique characteristics depending on the kind of the view they are included, requiring consideration of the compression efficiency. In this paper, the performance comparison analysis of screen content coding tools such as intra block copy (IBC) is conducted, based on the pattern of various views and patches repetition. It is demonstrated that the proposed method improves coding performance around -15.74% BD-rate reduction in the MIV.

Structural similarity based efficient keyframes extraction from multi-view videos (구조적인 유사성에 기반한 다중 뷰 비디오의 효율적인 키프레임 추출)

  • Hussain, Tanveer;Khan, Salman;Muhammad, Khan;Lee, Mi Young;Baik, Sung Wook
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.14 no.6
    • /
    • pp.7-14
    • /
    • 2018
  • Salient information extraction from multi-view videos is a very challenging area because of inter-view, intra-view correlations, and computational complexity. There are several techniques developed for keyframes extraction from multi-view videos with very high computational complexities. In this paper, we present a keyframes extraction approach from multi-view videos using entropy and complexity information present inside frame. In first step, we extract representative shots of the whole video from each view based on structural similarity index measurement (SSIM) difference value between frames. In second step, entropy and complexity scores for all frames of shots in different views are computed. Finally, the frames with highest entropy and complexity scores are considered as keyframes. The proposed system is subjectively evaluated on available office benchmark dataset and the results are convenient in terms of accuracy and time complexity.

Fast Intra Mode Decision Algorithm for Depth Map Coding using Texture Information in 3D-AVC (3D-AVC에서 색상 영상 정보를 이용한 깊이 영상의 빠른 화면 내 예측 모드 결정 기법)

  • Kang, Jinmi;Chung, Kidong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.2
    • /
    • pp.149-157
    • /
    • 2015
  • The 3D-AVC standard aims at improving coding efficiency by applying new techniques for utilizing intra, inter and view predictions. 3D video scenes are rendered with existing texture video and additional depth map. The depth map comes at the expense of increased computational complexity of the encoding process. For real-time applications, reducing the complexity of 3D-AVC is very important. In this paper, we present a fast intra mode decision algorithm to reduce the complexity burden in the 3D video system. The proposed algorithm uses similarity between texture video and depth map. The best intra prediction mode of the depth map is similar to that of the corresponding texture video. The early decision algorithm can be made on the intra prediction of depth map coding by using the coded intra mode of texture video. Adaptive threshold for early termination is also proposed. Experimental results show that the proposed algorithm saves the encoding time on average 29.7% without any significant loss in terms of the bit rate or PSNR value.

Multiple Camera Calibration for Panoramic 3D Virtual Environment (파노라믹 3D가상 환경 생성을 위한 다수의 카메라 캘리브레이션)

  • 김세환;김기영;우운택
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.2
    • /
    • pp.137-148
    • /
    • 2004
  • In this paper, we propose a new camera calibration method for rotating multi-view cameras to generate image-based panoramic 3D Virtual Environment. Since calibration accuracy worsens with an increase in distance between camera and calibration pattern, conventional camera calibration algorithms are not proper for panoramic 3D VE generation. To remedy the problem, a geometric relationship among all lenses of a multi-view camera is used for intra-camera calibration. Another geometric relationship among multiple cameras is used for inter-camera calibration. First camera parameters for all lenses of each multi-view camera we obtained by applying Tsai's algorithm. In intra-camera calibration, the extrinsic parameters are compensated by iteratively reducing discrepancy between estimated and actual distances. Estimated distances are calculated using extrinsic parameters for every lens. Inter-camera calibration arranges multiple cameras in a geometric relationship. It exploits Iterative Closet Point (ICP) algorithm using back-projected 3D point clouds. Finally, by repeatedly applying intra/inter-camera calibration to all lenses of rotating multi-view cameras, we can obtain improved extrinsic parameters at every rotated position for a middle-range distance. Consequently, the proposed method can be applied to stitching of 3D point cloud for panoramic 3D VE generation. Moreover, it may be adopted in various 3D AR applications.

Emergency Neuroendoscopic Management of Third Ventricular Neurocysticercosis Cyst Presented with Bruns Syndrome : Report of Two Cases and Review of Literature

  • Teegala, Ramesh;Rajesh, K. Ghanta;Raviprasad, V. Yerramsetty;Chennappa, Yemba
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.173-177
    • /
    • 2014
  • Neurocysticercosis is the commonest parasitic disease of the human central nervous system. The incidence of intra ventricular form of neurocysticercosis (NCC) is less common accounting 10-20% that of total central nerve system cysticercosis. Intra ventricular NCC is complicated due, to its high incidence of acute hydrocephalus caused by ball valve mechanism. The only reliable tool for diagnosis of NCC is by neuroimaging with CT or MRI. MRI preferred over CT because of its high specificity and sensitivity. In emergency situations like acute hydrocephalus one can proceed with emergency endoscopic surgery. Through the endoscopic view, intra ventricular NCC (IVNCC) has distinguished morphological features like the full moon sign. This feature not only helps in identification of IVNCC, but also guides in further endoscopic treatment strategy. Authors report two cases of 3rd ventricular NCC with acute hydrocephalus managed with emergency endoscopy. Authors have discussed the clinical features, intra operative endoscopic findings and role of endoscopy in emergency surgery for NCC with acute hydrocephalus.

An Energy Efficient Variable Area Routing protocol in Wireless Sensor networks (무선 센서 네트워크에서 에너지 효율적인 가변 영역 라우팅 프로토콜)

  • Choi, Dong-Min;Moh, Sang-Man;Chung, Il-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.8
    • /
    • pp.1082-1092
    • /
    • 2008
  • In wireless sensor networks, clustering protocol such as LEACH is an efficient method to increase whole networks lifetime. However, this protocol result in high energy consumption at the cluster head node. Hence, this protocol must changes the cluster formation and cluster head node in each round to prolong the network lifetime. But this method also causes a high amount of energy consumption during the set-up process of cluster formation. In order to improve energy efficiency, in this paper, we propose a new cluster formation algorithm. In this algorithm, we define a intra cluster as the sensor nodes within close proximity of each other. In a intra cluster, a node senses and transmits data at a time on the round-robin basis. In a view of whole network, intra cluster is treated as one node. During the setup phase of a round, intra clusters are formed first and then they are re-clustered(network cluster) by choosing cluster-heads(intra clusters). In the intra cluster with a cluster-head, every member node plays the role of cluster-head on the round-robin basis. Hence, we can lengthen periodic round by a factor of intra cluster size. Also, in the steady-state phase, a node in each intra cluster senses and transmits data to its cluster-head of network cluster on the round-robin basis. As a result of analysis and comparison, our scheme reduces energy consumption of nodes, and improve the efficiency of communications in sensor networks compared with current clustering methods.

  • PDF

Use of Subtalar Arthroscopy in Intra-Articular Calcaneus Fractures (관절 내 종골 골절에서 거골하 관절경술의 이용)

  • Inha Woo;Chul Hyun Park
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Displaced intra-articular calcaneal fractures are difficult to treat because of complex anatomy and high soft tissue complications. Various surgical approaches have been introduced to solve these problems, but the treatment remains complex. Recently, clinically and radiographically superior results were reported using a subtalar arthroscopy in reducing the posterior facet in both percutaneous and open approaches. In the percutaneous approach, the arthroscopically assistant percutaneous approach must be selected carefully for mild-to-moderately displaced fractures because of the limited view. In the open approach, there is little evidence of the utility of subtalar arthroscopy. Therefore, intraoperative arthroscopy should always be used in conjunction with fluoroscopy to achieve reduction and assess the internal fixation placement.

Ultra-mode Decision Algorithm for Fast Encoding of H.264/AVC Video (H.264/AVC비디오의 고속 부호화를 위한 인트라모드 선택 알고리듬)

  • Kim, Dong-Hyung;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6C
    • /
    • pp.585-593
    • /
    • 2007
  • For the improvement of coding efficiency, the H.264 standard uses new coding tools such as VBS, 1/4-pel accurate ME, multiple references, intra prediction, loop filter, etc. Using these coding tools, H.264 has achieved significant improvements from rate-distortion point of view compared to existing standards. However, the encoder complexity is greatly increased due to these coding tools. We focus on the complexity reduction method of intra-mode decision. Our algorithm first restricts selective prediction modes of Intra4x4 using a simple preprocessing. The prediction modes of Intra4x4 are used for restricting those of the other inter-modes. Simulation results show that the proposed method outperforms other conventional methods and save about 82% of total encoding time.

Fast Intra Mode Selection Algorithm Based on Edge Activity in Transform Domain for H.264/AVC Video (변환영역에서의 에지활동도에 기반한 H.264/AVC 고속 인트라모드 선택 방법)

  • Seo, Jae-Sung;Kim, Dong-Hyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.8C
    • /
    • pp.790-800
    • /
    • 2009
  • For the improvement of coding efficiency, the H.264/AYC standard uses new coding tools such as 1/4-pel-accurate motion estimation, multiple references, intra prediction, loop filter, variable block size etc. Using these coding tools, H.264/AYC has achieved significant improvements from rate-distortion point of view compared to existing standards. However, the encoder complexity was greatly increased due to these coding tools. We focus on the complexity reduction method of intra macroblock mode selection. The proposed algorithm for fast intra mode selection calculates the edge activity in transform domain, and performs fast encoding of intra frame in H.264/AYC through the fast prediction mode selection of intra4x4 and chrominance blocks. Simulation results show that the proposed method saves about 59.76% for QCIF sequences and 65.03% for CIF sequences of total encoding time, while bitrate increase and PSNR decrease are very small.