• 제목/요약/키워드: Intra-motion

검색결과 211건 처리시간 0.031초

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교 (A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods)

  • 김현숙;이원휘;정성대
    • 한국전문물리치료학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.

동영상 트랜스코더를 위한 적응적 인트라 매크로블록 업데이트에 대한 연구 (Adaptive Intra Macroblock Update for Video Transcoder)

  • 서동완;최윤식
    • 융합신호처리학회논문지
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 일반적으로 동영상 트랜스코딩 기술에서는 시스템의 복잡도를 줄이기 위해, 입력 비트열로부터 매크로블록 종류와 움직임 벡터, DCT 계수 등의 중간 데이터를 추출하여 사용한다. 본 논문에서는 프레임 내에서 매크로블록의 중요도를 이용한 새로운 인트라 매크로블록 업데이트 방법을 제안한다. 매크로블록의 중요도는 입력 비트열을 복호화하는 과정에서 얻어지는 움직임벡터에 의해 계산한다. 참조 프레임 내의 매크로블록의 참조율은 현재 복호화하는 프레임의 움직임 벡터에 의해서 계산이 가능하며, 참조율이 놀은 매크로블록은 다음 프레임과 그 이후 프레임에 영향력이 놀다 제안한 기법을 통해, 전송 오류에 대해 강인하고 더 우수한 화질을 나타내는 동영상 비트열을 얻을 수 있다.

  • PDF

H.264 Encoder Hardware Chip설계 (A design of Encoder Hardware Chip For H.264)

  • 서기범
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2647-2654
    • /
    • 2009
  • 본 논문에서는 AMBA 기반으로 사용될 수 있는 H.264용 Encoder Hardware 모듈 (Intra Prediction, Deblocking Filter, Context-Based Adaptive Variable Length Coding, Motion Estimation)을 Integration하여 설계하였다. 설계된 모듈은 한 매크로 블록당 최대 440 cycle내에 동작한다. 제안된 인코더 구조를 검증하기 위하여 JM 9.4부터 reference C를 개발하였으며, reference C로부터 test vector를 추출하여 설계 된 회로를 검증하였다. 제안된 회로는 최대 166MHz clock에서 동작하며, 합성결과 Charterd 0.18 um 공정에 램 포함 약 173만 gate 크기이다. MPW제작시 chip size $6{\times}6mm$의 크기와 208 pin의 Package 형태로 제작 하였다.

국내외 판내부 지진기록을 이용한 한국 표준수직설계스펙트럼의 개발 (Development of Korean Standard Vertical Design Spectrum Based on the Domestic and Overseas Intra-plate Earthquake Records)

  • 김재관;김정한;이진호;허태민
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.413-424
    • /
    • 2016
  • The vertical design spectrum for Korea, which is known to belong to an intra-plate region, is developed from the ground motion records of the earthquakes occurred in Korea and overseas intra-plate regions. From the statistical analysis of the vertical response spectra, a mean plus one standard deviation spectrum in lognormal distribution is obtained. Regression analysis is performed on this curve to determine the shape of spectrum including transition periods. The developed design spectrum is valid for the estimation both spectral acceleration and displacement. The ratio of vertical to horizontal response spectrum for each record is calculated. Statistical analysis of the ratios rendered the vertical to horizontal ratio (V/H ratio). Subsequently the ratio between the peak vertical ground acceleration to the horizontal one is obtained.

호흡 동조 췌장 암 용적 세기조절 회전 치료 시 Inter-fraction Intra-fraction 분석 (Analysis of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in Pancreas Ca)

  • 조영필;서동린;홍택균;강태영;백금문;홍동기;윤인하;김진산
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.247-256
    • /
    • 2014
  • 목 적 : 췌장 환자 방사선 치료 중 기점(Fiducial) 대상 내부 및 외부 종양 움직임의 오차를 정량화 하고자 한다. 또한 cone beam computed tomography (CBCT) 를 기반으로 호흡 시 췌장의 움직임 분석하고자 한다. 대상 및 방법 : 용적 세기변조 회전조사 (V-MAT)를 적용, 정위적 방사선 치료를 국소 진행성 췌장암 환자 11명을 대상으로 하였다. CBCT 및 직교 투시이미지를 적용하여 기점(Fiducial Marker)의 Inter, intra-fraction 움직임 변화를 치료 전, 치료 진행 시 분석하였다. 결 과 : 치료 후 프로토콜을 오프라인 교정 프로토콜을 사용하여, CBCT 와 직교투시 간의 평균 오차(범위)는 0.0(-1.7~4.0), 0.3(-0.5~3.0) and 0.0(-4.1~6.6)mm 측방 (LR), 세로 (AP) 및 종 방향 (SI) 이였다. 무작위 Inter-fraction Setup 오차 결과는 -0.1, -2.3 and -1.1 mm: 95% Fiducial포함 마진은 각 9.9, 7.8, 12.5mm로 수식되었다. 결 론 : 위 분석으로 뼈 일치 정렬 후 잔류 불확실성이 있으며, SI 방향에 큰 임의의 움직임은 적합한 여백이 필요하다. 주변 내부 장기를 보호, 내부 장기 문제점을 최소화, 호흡편차를 고려, 치료 시 정기적으로 측정하여야 한다.

반월상 연골 손상에 대한 관절강내 봉약침 치료 증례보고 4례 (The Effect of Intra-articular Bee Venom Injection on Meniscal Injury : Four Cases Report)

  • 김동은;유덕선;염승룡;권영달;송용선
    • 한방재활의학과학회지
    • /
    • 제20권1호
    • /
    • pp.219-230
    • /
    • 2010
  • According to previous reports, intra-articular bee venom injection is very effective for synovitis, intra-articular lesions. In this article, we report 4 cases of well-treated meniscal tear with intra-articular bee venom injection. We used intra-articular bee venom injection on meniscal tear diagnosed by MR imaging and prescribed herbal medication, physiotherapy if necessary. Outcomes were measured by Visual Analogue Scale(VAS) and Lysholm Knee Scoring Scale. Patients who are treated by intra-articular bee venom injection had a significant effect on the pain reduction, improved range of motion and knee function. Further well-designed, controlled studies and more cases are needed to define the effect of intra-articular bee venom injection on knee.

견관절 유착성 관절낭염에 대한 관절강 내 봉약침 적용 1례 (A Case Report of Intra-articular Bee Venom Pharmacopuncture for Adhesive Capsulitis)

  • 권오곤;이윤규
    • Journal of Acupuncture Research
    • /
    • 제29권4호
    • /
    • pp.99-103
    • /
    • 2012
  • Objectives : This study was performed to report a case of adhesive capsulitis treated by intra-articular bee venom pharmacopuncture. Methods : Patient was treated by intra-articular bee venom pharmacopuncture four times during two weeks, and after that the patient had intermission period for 2 weeks. The same treatment was administered four times during two weeks after the intermission. The effect of treatment was evaluated by visual analog scale(VAS), range of motion(ROM). Results : After treatment, VAS score declined from 7 to 4, ROM increased. Conclusions : Intra-articular bee venom pharmacopuncture was effective for adhesive capsulitis.

압축상태에서 MPEG2 P 프레임을 H.263 P 프레임으로 변환하기 위한 가이드 탐색 방법 연구 (A Study on the Guided Search Method for Transcoding MPEG2 P frame to H.263 P frame in a Compressed Domain)

  • 엄성민;강의선;임영환;황재각
    • 정보처리학회논문지B
    • /
    • 제9B권6호
    • /
    • pp.745-752
    • /
    • 2002
  • 본 논문은 이 기종간의 표준 압축형식을 변환하는데 있어 실시간 변환이 가능하도록 하며 프레임의 특성을 이용하여 압축률을 좀 더 높여 보는데 그 목적을 두고 있다. 이 기종간의 표준 압축형식 변환으로는 압축률이 낮은 MPEG2에서 압축률이 높은 H.263으로의 변환을 시도하였다. MPEG2에서 H.263으로 변환한 후 좀 더 압축률을 높이기 위하여 분석한 결과 MPEG2의 P 프레임내의 인트라 매크로블록 수가 H.263의 P 프레임의 인트라 매크로블록보다 많다는 것을 알 수 있었다. 인트라 매크로블록은 P 프레임을 생성하는 과정에서 움직임 예측 과정의 결과치가 임계치에 미치지 못했을 경우에 생성되는 것으로써 공간적인 압축 과정을 통하여 압축되기 때문에 P 프레임의 압축률에 큰 영향을 준다. 따라서 본 논문에서는 P 프레임의 압축률을 높이기 위하여 MPEG2 P 프레임에 생성된 인트라 매크로블록의 개수를 줄여 보았다. 이를 위한 해결방법으로써 P 프레임내의 인트라 매크로블록 변환 과정에 움직임 예측 과정을 삽입하여 변환하였다. 그리고 움직임 예측 과정의 복잡도를 줄이기 위하여 복원과정에서 알 수 있는 이웃하는 매크로블록의 정보와 움직임 벡터 정보를 이용하여 가이드 탐색 방법을 제안하였다. 실험 결과 MPEG2에서 H.263으로 변환이 실시간으로 이루어짐을 확인하였다.

지역 통계를 이용한 H.264/AVC의 고속 인터 모드 예측 (A fast Inter Mode Decision Based on Local Statistics in H.264/AVC)

  • 이동식;김영모
    • 한국멀티미디어학회논문지
    • /
    • 제10권8호
    • /
    • pp.997-1003
    • /
    • 2007
  • H.264/AVC는 프레임 간 움직임 추정에서 새로운 인트라 모드(intra mode)와 인터 모드(inter mode) 방식을 도입하여 프레임 간 압축률을 높이고 있다. 이들 두 모드들은 가변 크기 블록 모드를 사용하고 있으며 H.264 인코더는 이들 새로운 예측 모드들을 사용하여 이전 표준안들에 비해 뛰어난 압축률과 유연성을 제공해 준다. 그러나 압축률과 유연성에서 이득을 보는 대신, 이들 두 예측으로 인해 복잡도가 증가하고 부호화 시간을 많이 요구하게 되었다. 본 논문에서는 결과 인트라 모드, 움직임 벡터와 모드 맵의 지역 통계를 사용하여 인터 모드를 예측하는 기법을 제안한다. 인트라와 인터 모드는 선택되는 블록 크기에서 연관성을 보이고 있으며, 영상 내용의 stationary에 따라 주변 매크로 블록의 결과 모드와 움직임 벡터를 이용하여 매크로 블록의 인터 모드를 예측할 수 있다. 본 논문의 결과에서는 다양한 비트율과 여덟 개의 영상 열에서 FMD와 비교하여 PSNR과 비트 율에서 거의 비슷하면서 평균 39.43%의 부호화 시간을 감소시키는 것을 보여 주고 있다.

  • PDF

범함수 정의역 분할에 바탕을 둔 비선형 계층적 움직임 추정기법 (Nonlinear hierarchical motion estimation method based on decompositionof the functional domain)

  • 심동규;박래홍
    • 한국통신학회논문지
    • /
    • 제21권4호
    • /
    • pp.807-821
    • /
    • 1996
  • In this paper, we proposed a nonlinear hierarchical mtion estimation method. Generally, the conventional hierarchical motion estimation methods have been proposed for fast convergence and detection of large motions. But they have a common drawback that large error in motion estimation is propapated across motion discontinuities. This artifiact is due to the constriaint of motion continuity and the linear interpolation of motion vectors between hierarchical levels. In this paper, we propose an effective hierarchical motion estimation mechod that is robust to motion discontinuities. The proposed algorithm is based on the decomposition of the functional domain for optimizing the intra-level motion estimation functional. Also, we propose an inter-level nonlinear motion estimation equation rather than using the conventional linearprojection scheme of motion field. computer simulations with several test sequences show tht the proposed algorithm performs better than several conventional methods.

  • PDF