• Title/Summary/Keyword: Intervertebral height

Search Result 45, Processing Time 0.025 seconds

The Distance from Skin to Cervical Epidural Space (피부에서 경부 경막외강까지의 깊이에 대한 연구)

  • Han, Kyung-Ream;Kwak, No-Kil;Whang, Hyuk-Ie;Kim, Ji-Young;Kim, Chan;Kim, Seoung-Mo
    • The Korean Journal of Pain
    • /
    • v.11 no.1
    • /
    • pp.105-108
    • /
    • 1998
  • Backgrounds: Cervical epidural nerve block is useful in the management of a variety of acute, chronic and cancer related pain syndromes involving the head, face, neck and upper extrimity. To safely perfom the cervical epidural block, an appreciation of the expected distance from skin to epidural space is important. We studied the distance from skin to cervical epidural space of adults to determine if any relationship exists between patient height, weight and neck circumference and the distance from skin to epidural space. Methods: Patients 170, suffering from neck and upper extremity pain with cervical HIVD(herniated intervertebral dics) were selected. Cervical epidural block was performed at $C_{6\sim7}$ or $C_{7-}T_1$ intervertebral space. Then measured the distance from skin to epidural space and analysed the relationship between age, height, weight and neck circumference and the distance from skin to epidural space. Results: The cervical epidural depth of male $C_{6\sim7}$, male $C_{7-}T_1$, female $C_{6\sim7}$ and female $C_{7-}T_1$ groups were $5.17{\pm}0.63$, $5.47{\pm}0.59$, $4.84{\pm}0.56$ and $5.01{\pm}0.60$ cm respectively. Cervical epidural depth significantly correlated with body weight, ponderal index and neck circumference. Conclusions: The distance from skin to cervical epidural space has significant relationships with weight, ponderal index and neck circumference. Although experience is important, patient's weight and neck circumference are indicating factor, of the cervical epidural depth.

  • PDF

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Anterior Lumbar Interbody Fusion with Stand-Alone Interbody Cage in Treatment of Lumbar Intervertebral Foraminal Stenosis : Comparative Study of Two Different Types of Cages

  • Cho, Chul-Bum;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.352-357
    • /
    • 2010
  • Objective : This retrospective study was performed to evaluate the clinical and radiological results of anterior lumbar interbody fusion (ALIF) using two different stand-alone cages in the treatment of lumbar intervertebral foraminal stenosis (IFS). Methods : A total of 28 patients who underwent ALIF at L5-S1 using stand-alone cage were studied [Stabilis$^{(R)}$ (Stryker, Kalamazoo, MI, USA); 13, SynFix-LR$^{(R)}$ (Synthes Bettlach, Switzerland); 15]. Mean follow-up period was 27.3 ${\pm}$ 4.9 months. Visual analogue pain scale (VAS) and Oswestry disability index (ODI) were assessed. Radiologically, the change of disc height, intervertebral foraminal (IVF) height and width at the operated segment were measured, and fusion status was defined. Results : Final mean VAS (back and leg) and ODI scores were significantly decreased from preoperative values (5.6 ${\pm}$ 2.3 ${\rightarrow}$ 2.3 ${\pm}$ 2.2, 6.3 ${\pm}$ 3.2 ${\rightarrow}$1.6 ${\pm}$ 1.6, and 53.7 ${\pm}$ 18.6 ${\rightarrow}$ 28.3 ${\pm}$ 13.1, respectively), which were not different between the two devices groups. In Stabilis$^{(R)}$ group, postoperative immediately increased disc and IVF heights (10.09 ${\pm}$ 4.15 mm ${\rightarrow}$ 14.99 ${\pm}$ 1.73 mm, 13.00 ${\pm}$ 2.44 mm ${\rightarrow}$ 16.28 ${\pm}$ 2.23 mm, respectively) were gradually decreased, and finally returned to preoperative value (11.29 ${\pm}$ 1.67 mm, 13.59 ${\pm}$ 2.01 mm, respectively). In SynFix-LR$^{(R)}$ group, immediately increased disc and IVF heights (9.60 ${\pm}$ 2.82 mm ${\rightarrow}$ 15.61 ${\pm}$ 0.62 mm, 14.01 ${\pm}$ 2.53 mm ${\rightarrow}$ 21.27 ${\pm}$ 1.93 mm, respectively) were maintained until the last follow up (13.72 ${\pm}$ 1.21 mm, 17.87 ${\pm}$ 2.02 mm, respectively). The changes of IVF width of each group was minimal pre- and postoperatively. Solid arthrodesis was observed in 11 patients in Stabilis group (11/13, 84.6%) and 13 in SynFix-LR$^{(R)}$ group (13/15, 86.7%). Conclusion : ALIF using stand-alone cage could assure good clinical results in the treatment of symptomatic lumbar IFS in the mid-term follow up. A degree of subsidence at the operated segment was different depending on the device type, which was higher in Stabilis$^{(R)}$ group.

A Minimally Invasive Rabbit Model of Progressive and Reproducible Disc Degeneration Confirmed by Radiology, Gene Expression, and Histology

  • Kwon, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.323-330
    • /
    • 2013
  • Objective : To develop a simple, reproducible model of disc degeneration in rabbits through percutaneous annular puncture and to confirm the degree of degeneration over time. Methods : Fifteen New Zealand white rabbits (4 to 5 months old and weighing approximately 3 to 3.5 kg each) underwent annular puncture of the L2-L3, L3-L4, and L4-L5 discs. Rabbits were sacrificed at 4, 8, or 20 weeks after puncture. For a longitudinal study to assess changes in disc height over time, serial X-rays were performed at 0, 2, 4, 8, and 20 weeks for rabbits in the 20-week group. Upon sacrifice, the whole spinal column and discs were extracted and analyzed with magnetic resonance imaging (MRI), real time reverse transcriptase-polymerase chain reaction, and histological staining. Results : The X-rays showed a slow, progressive decrease in disc height over time. Significant disc space narrowing compared to preoperative disc height was observed during the time period (p<0.001). The MRI grade, aggrecan, and matrix metalloprotease-13 mRNA expression and hematoxylin and eosin/safranin O/anti-collagen II staining were consistently indicative of degeneration, supporting the results of the X-ray data. Conclusion : Percutaneous annular puncture resulted in slow, reproducible disc degeneration that was confirmed by radiology, biochemistry, and histology. This in vivo model can be used to study and evaluate the safety and efficacy of biologic treatments for degenerative disc disease.

The Morphometric Analysis of the Extraforamen in the Lumbosacral Spine: Magnetic Resonance Imaging and Computed Tomography Study

  • Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.336-339
    • /
    • 2005
  • Objective: The goal of this study is to establish the anatomical criteria of the normal and stenotic lumbosacral extraforaminal tunnel, and also to determine the effect of the pathologic intervertebral disc on the size of extraforaminal tunnel in the lumbosacral spine. Methods: MRI and CT scans were reviewed and classified into two groups: (1) 40 patients with normal discs at L5- S1 (Group 1) and (2) 43 patients that had undergone successful decompression surgery for extraforaminal entrapment at the lumbosacral region(Group 2). In these two groups, the following parameters were compared are compared: the distance between the disc margin and the ala (lumbosacral tunnel) on the axial MRI, and the posterior disc height at L5-S1 on the mid-sagittal MRI. Results: In the group 1, the mean distance of the lumbosacral tunnel on the axial MRI was $10.1{\pm}2.2mm$. The mean posterior disc height at L5-S1 was $7.4{\pm}1.7mm$ on the mid-sagittal MRI. In the group 2, the mean distance between the disc margin and the ala (costal process) was $1.6{\pm}1.3mm$ on the axial MRI. The average posterior disc height was $4.4{\pm}1.5mm$ on the mid-sagittal MRI. The posterior disc height and the size of the lumbosacral tunnel between the two groups were statistically different on the paired t-test (p<0.0001). However, the posterior disc height was not positively correlated with the size of the extraforaminal tunnel for group 2 (p=0.909). Conclusion: The extraforaminal stenosis was correlated to pathologic disc. However, the posterior disc height was not correlated to the size of the of the extraforaminal tunnel.

Radiologic Assessment of Subsidence in Stand-Alone Cervical Polyetheretherketone (PEEK) Cage

  • Ha, Sung-Kon;Park, Jung-Yul;Kim, Se-Hoon;Lim, Dong-Jun;Kim, Sang-Dae;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.6
    • /
    • pp.370-374
    • /
    • 2008
  • Objective : Aim of study was to find a proper method for assessing subsidence using a radiologic measurement following anterior cervical discectomy and fusion (ACDF) with stand-alone polyetheretherketone (PEEK), $Solis^{TM}$ cage. Methods : Forty-two patients who underwent ACDF with $Solis^{TM}$ cage were selected. With a minimum follow-up of 6 months, the retrospective investigation was conducted for 37 levels in 32 patients. Mean follow-up period was 18.9 months. Total intervertebral height (TIH) of two fused vertebral bodies was measured on digital radiographs with built-in software. Degree of subsidence (${\Delta}TIH$) was reflected by the difference between the immediate postoperative and follow-up TIH. Change of postoperative disc space height (CT-MR ${\Delta}TIH$) was reflected by the difference between TIH of the preoperative mid-sagittal 2D CT and that of the preoperative mid-sagittal T1-weighted MRI. Results : Compared to preoperative findings, postoperative disc height was increased in all cases and subsidence was observed only in 3 cases. For comparison of subsidence and non-subsidence group, TIH and CT-MR ${\Delta}TIH$ of each group were analyzed. There was no statistically significant difference in TIH and CT-MR ${\Delta}TIH$ between each group at 4 and 8 weeks, but a difference was observed at the last follow-up TIH (p=0.0497). Conclusion : ACDF with $Solis^{TM}$ cage was associated with relatively good radiologic long-term results. Fusion was achieved in 94.5% and subsidence occurred in 8.1% by the radiologic assessment. Statistical analysis reveals that the subsidence seen later than 8 weeks after surgery and the development of subsidence does not correlate statistically with the change of the postoperative disc space height.

Efficacy of a Novel Annular Closure Device after Lumbar Discectomy in Korean Patients : A 24-Month Follow-Up of a Randomized Controlled Trial

  • Cho, Pyung Goo;Shin, Dong Ah;Park, Sang Hyuk;Ji, Gyu Yeul
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.691-699
    • /
    • 2019
  • Objective : Lumbar discectomy is an effective treatment for lumbar disc herniation (LDH); however, up to 2-18% of patients with LDH have experienced recurrent disc herniation. The purpose of this study was to evaluate the efficacy of a novel annular closure device (ACD) for preventing LDH recurrence and re-operation compared with that of conventional lumbar discectomy (CLD). Methods : In this prospective randomized controlled trial, we compared CLD with discectomy utilizing the $Barricaid^{(R)}$ (Intrinsic Therapeutics, Inc., Woburn, MA, USA) ACD. Primary radiologic outcomes included disc height, percentage of preoperative disc height maintained, and re-herniation rates. Additional clinical outcomes included visual analog scale (VAS) scores for back and leg pain, Oswestry Disability Index (ODI) scores, and 12-item short-form health survey (SF-12) quality of life scores. Outcomes were measured at preoperation and at 1 week, 1, 3, 6, 12, and 24 months postoperation. Results : Sixty patients (30 CLD, 30 ACD) were enrolled in this study. At 24-month follow-up, the disc height in the ACD group was significantly greater than that in the CLD group ($11.4{\pm}1.5$ vs. $10.2{\pm}1.2mm$, p=0.006). Re-herniation occurred in one patient in the ACD group versus six patients in the CLD group (${\chi}^2=4.04$, p=0.044). Back and leg VAS scores, ODI scores, and SF-12 scores improved significantly in both groups compared with preoperative scores in the first 7 days following surgery and remained at significantly improved levels at a 24-month follow-up. However, no statistical difference was found between the two groups. Conclusion : Lumbar discectomy with the $Barricaid^{(R)}$ (Intrinsic Therapeutics, Inc.) ACD is more effective at maintaining disc height and preventing re-herniation compared with conventional discectomy. Our results suggest that adoption of ACD in lumbar discectomy can help improve the treatment outcome.

Subsidence of Cylindrical Cage ($AMSLU^{TM}$ Cage) : Postoperative 1 Year Follow-up of the Cervical Anterior Interbody Fusion

  • Joung, Young-Il;Oh, Seong-Hoon;Ko, Yong;Yi, Hyeong-Joong;Lee, Seung-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.367-370
    • /
    • 2007
  • Objective : There are numerous reports on the primary stabilizing effects of the different cervical cages for cervical radiculopathy. But, little is known about the subsidence which may be clinical problem postoperatively. The goal of this study is to evaluate subsidence of cage and investigate the correlation between radiologic subsidence and clinical outcome. Methods : To assess possible subsidence, the authors investigated clinical and radiological results of the one-hundred patients who underwent anterior cervical fusion by using $AMSLU^{TM}$ cage during the period between January 2003 and June 2005. Preoperative and postoperative lateral radiographs were measured for height of intervertebral disc space where cages were placed intervertebral disc space was measured by dividing the sum of anterior, posterior, and midpoint interbody distance by 3. Follow-up time was 6 to 12 months. Subsidence was defined as any change in at least one of our parameters of at least 3 mm. Results : Subsidence was found in 22 patients (22%). The mean value of subsidence was 2.21 mm, and mean subsidence rate was 22%. There were no cases of the clinical status deterioration during the follow-up period No posterior or anterior migration was observed. Conclusion : The phenomenon of subsidence is seen in substantial number of patients. Nevertheless, clinical and radiological results of the surgery were favorable. An excessive subsidence may result in hardware failure. Endplate preservation may enables us to control subsidence and reduce the number of complications.

Radiological Findings of Relation Between Intercrestal Line and HIVD of Lumbar Spine (Intercrestal line 높이와 요추 추간판 탈출증의 상관관계에 대한 영상학적 연구)

  • Choo, Won-Jung;Kim, Min-Yeong;Seo, Min-Soo;Lee, Cha-Ro;Choi, Hee-Seung;Choi, Young-Il;Nam, Hang-Woo
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • Objectives : The purpose of this study is to find out the relation between the height of intercrestal line, and HIVD(Herniated Intervertebral Disc)of Lumbar spine. Methods : We investigated 445 cases (208 male, 237 female) of patients who were diagnosed as HIVD of L-spine at either L4/5 or L5/S1 level. We analysed the relation between the height of intercrestal line and the level of HIVD. Results : 1. Among 445 cases, the level of intercrestal line with HIVD of L-spine at the specific location was different between male and female. In male, the intercrestal line is more likely to be located at L4 level, while in female more likely to be located at L5 level. 2. Among 445 cases, L5/S1 HIVD patients(272, 61.1%) were more than L4/5 HIVD patients(173, 38.9%). At L4 body area, L4/5 HIVD patients were more than L5/S1 HIVD patients, however, at L4/5 intervertebral area and L5 body area, L5/S1 HIVD patients were more than L4/5 HIVD patients. (p<0.01) 3. When the line is located at higher level, HIVD of L-spine tends to be occurred at L4/5 level. Contrastly, when the line is located at lower level, HIVD of L-spine tends to be occurred at L5/S1 level. (p<0.01) Conclusions : High intercrestal line leads to L4/5 HIVD, while low intercrestal line leads to L5/S1 HIVD. Possibly, it is caused by different length and thickness of the iliolumbar ligament.

  • PDF

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.