• 제목/요약/키워드: Interrupt Circuit

검색결과 60건 처리시간 0.03초

향후 DC 전력 계통에서의 자려 공진 DC 차단기에 관한 연구 (Study of Self-excited Resonant DC Circuit Breaker in Future DC Grid)

  • 곽정래;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.396-397
    • /
    • 2015
  • With the increasing utilization of high-voltage, direct current (HVDC) transmissions in modern power systems, the DC grid is becoming a hot topic in academic and practical systems. In the DC grid, one of the urgent problems is the fast clearance of the DC fault in the DC network. One preferred method is to isolate the faulty point from the DC network in a short time. The DC circuit breaker is to interrupt the overcurrent after DC faults occur. In this paper, a self-excited resonant DC circuit breaker is an easy and cheap equipment to interrupt the DC fault current. The Mayr's arc model is utilized to simulate the self-excited DC circuit breaker in a DC test system in PSCAD/EMTDC.

  • PDF

시험용 이상전원(異狀電源) 발생장치의 개발에 관한 연구 (A Study on the Development of Abnormal Power Source Generator to Evaluate Electronic Appliances)

  • 박찬원;노재관
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.83-90
    • /
    • 2004
  • Generally, electronic appliances are used on the basis of normal power source supply. The power source inevitably includes the abnormal condition, such as, sudden voltage sagging, power interrupt, and induced noises. As the electronic appliances which include micro-controller-based circuits are being increased recently, the controller circuit sometimes malfunctions by the abnormal condition of the power source. This situation causes serious problems such as hitch of electric appliance, fire and medical instrument glitch, which produces serious situations. In this paper, development of power interrupt tester which is highly suitable for an endurance test device under abnormal power source to microprocessor-based circuits is proposed 89C2051 microcontroller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

GMA용접의 용접신호 모니터링에 관한 연구 (A study on monitoring of welding signals in gas metal arc welding)

  • 신정식;김재웅;나석주
    • Journal of Welding and Joining
    • /
    • 제9권3호
    • /
    • pp.34-40
    • /
    • 1991
  • An automatic welding system was constructed with a personal computer to capture the welding data in addition to vision seam tracking for the gas metal arc welding process. The monitoring of welding signals is composed of the acquisition of welding voltage and current, obtained by using two differential amplifiers and A/D converters, and processing of the measured data. Using interrupt handing circuit for time sharing, two jobs of seam tracking and monitoring were performed at the required sampling time. Relations between welding signals and various welding circumstances were analyzed from the experimental results.

  • PDF

강자계 구동형 460V/225A/50kA 배선용 차단기 대전력 차단성능평가 (Interrupting Test of Molded Case Circuit Breaker with Strong Driving Magnetic Force)

  • 최영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.36-38
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widly used in power distribution systems. In the paper, it was investigated how much Interrupting capability was improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), Prior to the interrupting testing, it was necessary for the optimum design to analyze magnetic forces on the contact system, generated by current and flux density. This paper presents both our compuational analysis and test results contact system in MCCB.

  • PDF

고속도 차단기에 대한 사고전류 감지기의 적용연구 (Application of the Fault current detector to High speed circuit breaker)

  • 이우영;송기동;박경엽
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 2003
  • In this paper the performance of the high speed circuit breaker with fault current detector is described. The operating mechanism of circuit breaker in use is a magnetic actuator and a fault current detector is based on the DSP and A/D converter. The results show that 3-cycle is enough to interrupt the fault current and the more speed up performance is expected with on-going project.

  • PDF

Arc Fault Circuit Interruption Design

  • Kang, C.S.
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.384-386
    • /
    • 2006
  • In this paper, arc current controller is designed for the interruption of arc fault current which is occurred in the low voltage network. Arc in electrical network have the characteristics of low current, high impedance and high frequency. Conventional controller does not have the arc current interrupt function. Hence, arc current controller is designed for the interruption of arc fault current.

  • PDF

Design of an Arc Current Controller for Arc Interruption

  • Kang, Chang-Soo
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.109-113
    • /
    • 2007
  • In this paper, an arc current controller was designed for the interruption of arc fault currents occurred in a low voltage network. Arc in an electrical network represents the characteristics of low current, high impedance, and high frequency. Conventional controllers do not have arc current interrupt functions. Thus, an arc current controller was designed for the interruption of arc fault currents.

대체 카운터 전압(ACV) DC 하이브리드 회로 차단기(DC-HCB)의 EMTP 모델링 (EMTP Modeling of an Alterative Counter voltage (ACV) DC Hybrid Circuit Breaker (DC-HCB))

  • 라자무하마드카짐;이상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.601-602
    • /
    • 2015
  • Interruption of AC is easier due to natural occuring of zero crossings. In DC, zero crossings is achieved by Forced commutation technique. In this paper an alternative counter voltage(ACV) DC Hybrid Circuit breaker(DC-HCB) is modeled using EMTP/ATP tool, Results show that, ACV DC-HCB can interrupt DC with in 5ms with a source voltage of upto 1 KV.

  • PDF

개극시간 조정회로를 삽입한 축소형 가스절연 차단기 (Compact Gas-Insulated Circuit-Breaker adopting opening-time control circuits)

  • 김정배;김두성;서경보;양대일;송원표;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.485-487
    • /
    • 2004
  • High-voltage gas-insulated circuit-breaker must interrupt short-circuit current successfully when breakdown occurs in electric power system. Among many test-duties, Basic Terminal fault T100a(BTF T100a) is the one of the severest duties because of its high DC component of short-circuit current. In this paper, we developed 245kV 50kA gas circuit breaker using control circuits to reduce DC component while interrupting short-circuit current, then got good performance through high-power tests in Korea Electrotechnology Research Institute(KERI) and KEMA

  • PDF