• Title/Summary/Keyword: International Electronic Transmission

Search Result 75, Processing Time 0.023 seconds

Pre-Equalization Techniques for Mitigating Rain Attenuation Channels in a Broadband Fixed Wireless Uplink System

  • Lee, Yeon-Woo;Cho, Choon-Geun;Hur, Kyeong;Cho, Kwang-Moon;Alsusa, Emad
    • International Journal of Contents
    • /
    • v.2 no.4
    • /
    • pp.19-24
    • /
    • 2006
  • In this paper, the performance of pre-equalization technique which can be applicable for the B-WLL uplink is evaluated and compared to post-equalization technique under three kinds of rain attenuation channels such as rain, intermittent light rain and thundershower. The BER performance comparisons of two algorithms (LMS and RLS) are investigated in the context of channel models and the length of training sequence. From the simulation results, it is shown that the post-equalization outperforms only at quite good channel conditions such as AWGN, while the pre-equalization can guarantee better BER performance at every channel conditions, especially performance gain increases as the severity of channel increases. It is concluded that the pre-equalizer using LMS algorithm is preferable at delay-tolerant situation where the complexity of algorithm is not a strict factor, while one using RLS is suitable for fast burst transmission with a relatively short training sequence.

  • PDF

Performance Analysis of UWA Communication System by Diversity in UWA Channel (수중 음향 다중 경로 채널에서 수중 음향 통신 시스템 성능 분석)

  • Lee, Hojun;Kang, Jiwoong;Ahn, Jongmin;Chung, Jaehak
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.4
    • /
    • pp.191-198
    • /
    • 2017
  • In this paper, we compare the transmission performance of Code Division Multiple Access (CDMA) and Orthogonal Frequency Division Multiplexing (OFDM) under long duration multipath channel environments. This paper generates underwater channels through Bellhop based on the underwater environmental data of the west sea. BER performance of CDMA and OFDM are analyzed through various underwater channels based on the channels. Computer simulations result show that CDMA has better performance than OFDM when multipath delay time of underwater channel is shorter than spreading factor (SF). However, OFDM has better BER performance than CDMA as multi-path delay time increases.

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

A Practical Measurement Method of the Occupied Bandwidth for 8-VSB DTV Signal Using Modified ACPR

  • Kim, Young Soo;Lee, Bong Gyou;Song, Kyeongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3550-3565
    • /
    • 2019
  • This paper proposes a new measurement method for the effective measurement of the 99% occupied bandwidth (OBW) at monitoring stations. Although the OBW measurement of radio signal is recommended by the International Telecommunication Union Radio (ITU-R) with several methods, there still does not exist a clear measurement recommendation or standard for terrestrial DTV signal on-air environment. Modified adjacent channel power ratio (MACPR), which can be applied to 8-VSB (Vestigial Side Band) DTV (Digital Television) signal, is herein defined to verify the results of measurements obtained using the proposed measurement method. MACPR is a proper measuring parameter for determining the measuring area of a monitoring station. From measurement results obtained in real field environment, it has been found that the OBW of 8-VSB DTV signal can be effectively measured in areas where the MACPR value is over 35 dB and when the measurements are repeated more than 600 times in the same reception site. It also has been verified that measured results are within an error range of +/-0.1% compared to results directly obtained at a transmission station. It is expected that the proposed method is able to be employed in order to determine the proper location of monitoring station and provide a reliable OBW measurement procedure for 8-VSB DTV signal on-air environment.

A Study on the Information Exchange in Container Cargo Logistics (우리나라 컨테이너 물류 정보 교환에 관한 연구)

  • 박남규
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.3
    • /
    • pp.81-103
    • /
    • 1994
  • Increasing costs and competition in the global trade and transportation arena have led to a search for effient, cost-effective, particularly through the application of computer and information technologies. Most recently the introduction of Electronic Data Interchange(EDI) technologies in both trading and trade facili-tation activitiess have bagun to change the complextion of the international transport space. Korea as well as the other developing countries has become aware of the need to embrace EDI strate-gies in order to maintain a competitive market position with their more technologically advanced neighbou-ring and international trading partners. A way of EDI implementation, KMPA has invested large budgets in the research of the EDI since 1990. As the result of study in EDI of transport, KL-Net(Korea Logistics Network) was organized for the EDI business in cargo logistics. In spite of these KMPA's activities, the development plan of container logistics data interchange is not good and useful. So a new model of EDI in transportation is required by using the concepts of cargo data sharing. The purpose of this paper is to suggest a new way of container logistics data interchange model. This paper therefore analyze the information flow in the current container logistics and find the problem in the area to derive a new model. The followings are the results of this paper : (1) There are many problems and user's requirements in container logistics data interchange in Korea. (2) Many messages of UN/EDIFACT are able to be used in container logistics data interchange. (3) The container cargo data are stored in Container Logistics Network(CL-Net) database. And when necessary by requesting message transmission, the container logistics data interchange is possible. (4) Customs cargo clearance system and PORT-MIS can be linked to CL-Net. If the systems, however, are to introduce EDI in data interchange, the quality of user's software has to be assured.

  • PDF

Handling Of Sensitive Data With The Use Of 3G In Vehicular Ad-Hoc Networks

  • Mallick, Manish;Shakya, Subarna;Shrestha, Surendra;Shrestha, Bhanu;Cho, Seongsoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • Data delivery is very challenging in VANETs because of its unique characteristics, such as fast topology change, frequent disruptions, and rare contact opportunities. This paper tries to explore the scope of 3G-assisted data delivery in a VANET within a budget constraint of 3G traffic. It is started from the simple S_Random (Srand) and finally reached the 3GSDD, i.e., the proposed algorithm. The performance evaluation of different algorithms is done through the two metrics delivery ratio and average delay. A third function utility is created to reflect the above two metrics and is used to find out the best algorithm. A packet can either be delivered via multihop transmissions in the VANET or via 3G. The main challenge is to decide which set of packets should be selected for 3G transmissions and when to deliver them via 3G. The aim is to select and send those packets through 3G that are most sensitive and requiring immediate attention. Through appropriate communication mechanism, these sensitive information are delivered via VANET for 3G transmissions. This way the sensitive information which could not be transmitted through normal VANET will certainly find its destination through 3G transmission unconditionally and with top priority. The delivery ratio of the packets can also be maximized by this system.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.

Generation, Storing and Management System for Electronic Discharge Summaries Using HL7 Clinical Document Architecture (HL7 표준임상문서구조를 사용한 전자퇴원요약의 생성, 저장, 관리 시스템)

  • Kim, Hwa-Sun;Kim, Il-Kon;Cho, Hune
    • Journal of KIISE:Databases
    • /
    • v.33 no.2
    • /
    • pp.239-249
    • /
    • 2006
  • Interoperability has been deemphasized from the hospital information system in general, because it is operated independently of other hospital information systems. This study proposes a future-oriented hospital information system through the design and actualization of the HL7 clinical document architecture. A clinical document is generated using the hospital information system by analysis and designing the clinical document architecture, after we defined the item regulations and the templates for the release form and radiation interpretation form. The schema is analyzed based on the HL7 reference information model, and HL7 interface engine ver.2.4 was used as the transmission protocol. This study has the following significance. First, an expansion and redefining process conducted, founded on the HL7 clinical document architecture and reference information model, to apply international standards to Korean contexts. Second, we propose a next-generation web based hospital information system that is based on the clinical document architecture. In conclusion, the study of the clinical document architecture will include an electronic health record (EHR) and a clinical data repository (CDR), and also make possible medical information-sharing among various healthcare institutions.

ROUTE/DASH-SRD based Point Cloud Content Region Division Transfer and Density Scalability Supporting Method (포인트 클라우드 콘텐츠의 밀도 스케일러빌리티를 지원하는 ROUTE/DASH-SRD 기반 영역 분할 전송 방법)

  • Kim, Doohwan;Park, Seonghwan;Kim, Kyuheon
    • Journal of Broadcast Engineering
    • /
    • v.24 no.5
    • /
    • pp.849-858
    • /
    • 2019
  • Recent developments in computer graphics technology and image processing technology have increased interest in point cloud technology for inputting real space and object information as three-dimensional data. In particular, point cloud technology can accurately provide spatial information, and has attracted a great deal of interest in the field of autonomous vehicles and AR (Augmented Reality)/VR (Virtual Reality). However, in order to provide users with 3D point cloud contents that require more data than conventional 2D images, various technology developments are required. In order to solve these problems, an international standardization organization, MPEG(Moving Picture Experts Group), is in the process of discussing efficient compression and transmission schemes. In this paper, we provide a region division transfer method of 3D point cloud content through extension of existing MPEG-DASH (Dynamic Adaptive Streaming over HTTP)-SRD (Spatial Relationship Description) technology, quality parameters are further defined in the signaling message so that the quality parameters can be selectively determined according to the user's request. We also design a verification platform for ROUTE (Real Time Object Delivery Over Unidirectional Transport)/DASH based heterogeneous network environment and use the results to validate the proposed technology.

Shortening of Nursing Record Time about Real Time Transmission Effect of Blood Pressure, Blood Glucose Value Based on U-Healthcare (유-헬스케어 기반 실시간 혈압, 혈당 측정치 전송의 간호기록 시간 단축)

  • Park, Jeong-Eun;Kim, Hwa-Sun;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.4
    • /
    • pp.164-172
    • /
    • 2013
  • Purpose: The aim was to measure the real-time trans-mission effect of blood-pressure and blood-glucose value based on u-healthcare for saving the time and effort of nursing recording time. Methods: This study used a u-healthcare system based on the international standards for the exchange of health information. In order to verify the effectiveness of the u-healthcare, a clinical trial for the system regarding blood-pressure and blood-glucose targeting of patients with endocrine disorders at KNUH from February 7 to 9, 2012 was performed. Results: According to the analyzed results, of the 86 times the 11 patients were tested, measuring blood-pressure and blood-glucose using the u-healthcare system, we found the time differences between the real-time transfer recording method and existing hospital records that were used in the hospital. Based on the average time interval, there was a difference of 1,090.45 seconds (18.17 minutes). Conclusion: Therefore, it's cumbersome that nurses in the hospital have to record the numerical values of the measured blood-pressure and blood-glucose manually and input the recorded values directly into the electronic nursing record system. However, it was found in terms of the newly designed system, that it could save time and effort for nurses, since measured information is sent to the hospital information system on a real-time basis.