풍력단지 출력 검증을 위한 기상탑의 최적위치 선정 (Optimal Location of Meteorological Mast for Power Curve Verification of Wind Farm)

  • 오기용;이준신;박준영;이재경;김지영
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on "Power performance measurements of electricity producing wind turbines". By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.

  • PDF

The development of a ship's network monitoring system using SNMP based on standard IEC 61162-460

  • Wu, Zu-Xin;Rind, Sobia;Yu, Yung-Ho;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권10호
    • /
    • pp.906-915
    • /
    • 2016
  • In this study, a network monitoring system, including a secure 460-Network and a 460-Gateway, is designed and developed according with the requirements of the IEC (International Electro-Technical Commission) 61162-460 network standard for the safety and security of networks on board ships. At present, internal or external unauthorized access to or malicious attack on a ship's on board systems are possible threats to the safe operation of a ship's network. To secure the ship's network, a 460-Network was designed and implemented by using a 460-Switch, 460-Nodes, and a 460-Gateway that contains firewalls and a DMZ (Demilitarized Zone) with various application servers. In addition, a 460-firewall was used to block all traffic from unauthorized networks. 460-NMS (Network Monitoring System) is a network-monitoring software application that was developed by using an simple network management protocol (SNMP) SharpNet library with the .Net 4.5 framework and a backhand SQLite database management system, which is used to manage network information. 460-NMS receives network information from a 460-Switch by utilizing SNMP, SNMP Trap, and Syslog. 460-NMS monitors the 460-Network load, traffic flow, current network status, network failure, and unknown devices connected to the network. It notifies the network administrator via alarms, notifications, or warnings in case any network problem occurs. Once developed, 460-NMS was tested both in a laboratory environment and for a real ship network that had been installed by the manufacturer and was confirmed to comply with the IEC 61162-460 requirements. Network safety and security issues onboard ships could be solved by designing a secure 460-Network along with a 460-Gateway and by constantly monitoring the 460-Network according to the requirements of the IEC 61162-460 network standard.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

유방영상에서 엣지를 이용한 물리적 영상 평가 (Evaluation of the Performance Characteristic for Mammography by Using Edge device)

  • 김기원;최관우;정회원;장서구;이을규;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.415-420
    • /
    • 2016
  • 본 연구에서는 맘모그래피 장비에 대한 유지 보수에 대한 진단을 하는데 있어서 필수적인 정확성을 높이기 위해서 edge방법을 이용한, 유방영상의 물리적 특성에 대해서 알아보고자 한다. International electronical commission standard IEC: 61267의 RQA-M2 방법에 의해서 변조전달함수(modulation transfer function: MTF), 잡음전력스펙트럼(noise power spectrum: NPS), 양자검출효율(detective quantum efficiency: DQE)등을 측정하였다. 결과는 selenia demensions의 tomo장비와 lorad selenia는 맘모 전형장비의 MTF는 $10mm^{-1}$에서의 공간분해능을 유지하고 있었으며, NPS와 DQE는 낮은 nyquist frequency 포함하여 $6.0mm^{-1}$까지 나왔다. 따라서 정확한 진단을 위하여 주기적인 맘모시스템의 유지보수가 필요하며, 본 연구는 DDR 맘모시스템의 QA 및 수행성능 평가에 기초가 될 것으로 생각된다.

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

변조전달함수를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능 평가 (Evaluation of the Spatial Resolution for Exposure Class in Computed Radiography by Using the Modulation Transfer Function)

  • 성열훈
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.273-279
    • /
    • 2013
  • 본 연구에서는 변조전달함수(Modulation transfer function, MTF)를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능을 평가하여 컴퓨터 방사선영상 획득의 기초자료로 제시하고자 하였다. 본 실험에서는 $100{\mu}mm$ 픽셀의 영상판을 이용하여 엣지법의 MTF를 측정하였다. 방사선 선질은 IEC 61267에서 권고하고 있는 RQA5를 이용하였다. X-선이 조사된 영상판은 감도 노출 분류를 50, 100, 200, 300, 400, 600, 800, 1200으로 각각 설정한 후 디지털 영상화하였다. 최종 획득된 영상들은 공인된 영상분석 프로그램인 image J와 Origin 8.0을 이용하여 MTF 50%와 10%를 구하여 평가하였다. 그 결과 감도 노출 분류 200에서 가장 우수한 MTF 50%($1.979{\pm}0.114lp/mm$)와 MTF 10%($3.932{\pm}0.041$)의 공간주파수를 구하였다. 따라서 골절 등과 같이 높은 공간분해능을 요구하는 질병진단에 유용할 것으로 사료된다.

선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가 (Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교 (Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 김기원;최관우;정회원;장서구;권경태;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.171-176
    • /
    • 2016
  • 영상화 품질향상은 방사선 치료영역과 진단영역의 영상화 검사와 같이 quality assurance (QA) 장비들의 특성평가에 매우 중요한 요소이다. 본 연구의 목적은 치료장비의 megavoltage X-ray 에너지를 사용하여 측정방법에 있어서 NPS에 대한 수평, 수직적인 방법에 대한 측정결과를 비교 평가하는 것이다. 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission (IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 사용한 전자포털 영상장치(electronic portal imaging device, EPID)는 Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 데이터들로부터 각각의 주파수 값에 대응하는 노이즈 값들의 평균에 대해서, 각각의 주파수 별로 대응해서 표현하였으며, 수평 수직되어있는 주파수별 평균값의 노이즈값을 합산해서 정량적으로 장비마다 비교 평가하였다. 결과값은 Elekta iView에서 4가지 방법론에 의한 가로방향에서의 horizontal측정된 NPS값과 vertical 세로방향에서의 측정치는 비슷한 경향성에 따라서 horizontal과 vertical값은 3~5%정도의 차이가 있었으며, Siemens BEAMVIEW$^{PLUS}$, Varian Clinac$^R$ iX aS1000에서 horizontal측정된 NPS값과 vertical 측정된 NPS값은 편차의 차이가 전체값의 평균으로 했을 시 horizontal과 vertical값은 15%정도의 차이가 나타남을 보였다. 본 연구에서는 수평 수직되어있는 주파수별 평균값의 노이즈값을 합산해서 정량적으로 장비마다 비교 평가하였으며, 정량적인 평가방안을 제시하였다는 점을 둘 수 있다.

방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교 (Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;정회원;권경태;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.99-105
    • /
    • 2016
  • 잡음전력스펙트럼 (noise power spectrum, NPS)는 noise 진폭의 측정과 균일한 방사선 영역으로부터 획득된 영상의 품질에 가장 일반적인 방법 중 하나이다. 이 연구의 목적은 megavoltage X-ray 에너지를 사용하여 다른 잡음 전력스펙트럼 방법론들을 비교하는 것이다. 진단 영역에서의 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission(IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 우리가 사용한 전자포털영상장치(electronic portal imaging device, EPID)는 Varian TrueBeam$^{TM}$, Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 잡음전력스펙트럼의 관심영역을 측정하기 위해, 우리는 겹침 (overlapping), 비겹침 (non-overlapping), 평탄도 (flatness), 반음영 (penumbra) 4가지 인자를 사용하였다. 결과적으로는 Siemens BEAMVIEW$^{PLUS}$, Varian TrueBeam$^{TM}$ flattening filter, Varian Clinac$^R$ iX aS1000, Varian TrueBeam$^{TM}$ flattening filter free에서의 잡음 (noise) 분포는 기존의 첫번째, 두번째, 세번째 실험방법보다는 Elekta iViewGT보다 현격하게 높은 noise 분포가 나타남을 알 수 있다. 이번 연구는 다양한 인자들이 잡음전력스펙트럼의 megavoltage imaging (MVI)영상에서 MVI영역에서 잡음전력 스펙트럼의 기준의 방법론으로 사용되어질 수 있다는 것을 보여주었다.

시간에 따르는 CR장비의 영상의 질평가 (Measurement of Image Quality According to the Time of Computed Radiography System)

  • 손순룡;최관우;김정민;정회원;권경태;황선광;이익표;김기원;정재용;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.365-374
    • /
    • 2015
  • 진단의 높은 정확성을 유지하기 위하여 영상 품질의 정기적인 quality assurance (QA) 검사는 필수적이다. 이 연구의 목적은 2006년부터 2015년까지 시간에 따른 (2006, 2009, 2012, 2015) computed radiography (CR) system의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하여 평가 하는 것이다. 우리는 edge method를 이용하여 pre-sampled MTF를 구하였고 international electrotechnical commission standard IEC: 62220-1의 RQA5가 측정에 적용되었으며, X선관 초점으로부터 CR 표면까지의 거리는 150 cm이며, 부가필터 21 mmAl을 사용하였다. 관전압은 $72{\pm}2kVp$였으며 관전압을 1~2 kVp조절하여 HVL이 $7.1{\pm}1mmAl$되도록 하였다. 연구결과는 MTF의 공간주파수 50% ($mm^{-1}$)에서 사용 기간 별로 2006년은 1.54, 2009년은 1.14, 2012년은 1.12, 2015년은 1.38 이었고 공간주파수 10% ($mm^{-1}$)에서 사용 기간 별로 2006년은 2.68, 2009년은 2.44, 2012년은 2.44, 2015년은 2.46 이었다. 각각의 노이즈 분포는 2006년이 가장 낮은 노이즈 분포를 보였으며 2015, 2009, 2012 순으로 낮은 노이즈 분포를 나타내었다. Peak DQE와 $1mm^{-1}$에서도 2006년이 가장 우수한 DQE를 보였으며 2015년, 2009년, 2012년 순으로 DQE값을 나타내었다. 정확한 진단을 위하여 주기적인 CR 시스템의 유지보수가 필요하며 본 연구는 CR 시스템의 QA 및 수행성능 평가에 기초가 될 것으로 생각된다.