• 제목/요약/키워드: International Electro-technical Commission

검색결과 24건 처리시간 0.018초

저압직류전기설비 표준화 정책 도입의 필요성 및 제안에 관한 연구 (A Study on Proposal and Necessity to Adopt the LVDC Standardization Policy)

  • 오두석;강승진
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.121-127
    • /
    • 2015
  • Recently, LVDC(Low Voltage Direct Current) has been came into the newly spotlight with HVDC(High Voltage Direct Current) and as increasing digital load, DC power supply and high quality of demand is also getting extended. In accordance with the report of EPRI(Electric Power Research Institute), they expect digital load will grow to 50% of whole load in 2020. Subsequently, the use of DC equipment will grow dramatically. Therefore, the careful adoption of LVDC standardization policy is urgently required for the safety of people, prevention of confusion and occupancy of the market.

풍력단지 출력 검증을 위한 기상탑의 최적위치 선정 (Optimal Location of Meteorological Mast for Power Curve Verification of Wind Farm)

  • 오기용;이준신;박준영;이재경;김지영
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on "Power performance measurements of electricity producing wind turbines". By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.

  • PDF

IEC 62279 규격의 소프트웨어 정적분석에 관한 연구 (A Study on Software Static Analysis Method on IEC 62279)

  • 김철환;이창룡;이재호;김재식;이기서
    • 한국전자통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.513-519
    • /
    • 2015
  • 정적분석방식은 소프트웨어 코드분석방식중의 하나이다. 국제철도신호시스템 소프트웨어 관련규격 IEC 62279에서는 소프트웨어 안전성 레벨에 따라 총 9가지 분석방법을 조합하여 사용할 것을 권고하고 있다. 본 논문에서는 도시철도 차 지상간 열차운행 정보 통신장치 연구개발에서 소프트웨어 품질을 향상하기 위하여 세 가지 정적분석방식에 대하여 연구하고, LDRA 툴을 이용하여 사례 연구를 진행하였다. 따라서 철도신호시스템 소프트웨어개발주기에 필요한 시간을 단축하여 안전성 관련 소프트웨어의 효율적인 개발에 도움을 주고자 한다.

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

유방영상에서 엣지를 이용한 물리적 영상 평가 (Evaluation of the Performance Characteristic for Mammography by Using Edge device)

  • 김기원;최관우;정회원;장서구;이을규;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.415-420
    • /
    • 2016
  • 본 연구에서는 맘모그래피 장비에 대한 유지 보수에 대한 진단을 하는데 있어서 필수적인 정확성을 높이기 위해서 edge방법을 이용한, 유방영상의 물리적 특성에 대해서 알아보고자 한다. International electronical commission standard IEC: 61267의 RQA-M2 방법에 의해서 변조전달함수(modulation transfer function: MTF), 잡음전력스펙트럼(noise power spectrum: NPS), 양자검출효율(detective quantum efficiency: DQE)등을 측정하였다. 결과는 selenia demensions의 tomo장비와 lorad selenia는 맘모 전형장비의 MTF는 $10mm^{-1}$에서의 공간분해능을 유지하고 있었으며, NPS와 DQE는 낮은 nyquist frequency 포함하여 $6.0mm^{-1}$까지 나왔다. 따라서 정확한 진단을 위하여 주기적인 맘모시스템의 유지보수가 필요하며, 본 연구는 DDR 맘모시스템의 QA 및 수행성능 평가에 기초가 될 것으로 생각된다.

변조전달함수를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능 평가 (Evaluation of the Spatial Resolution for Exposure Class in Computed Radiography by Using the Modulation Transfer Function)

  • 성열훈
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.273-279
    • /
    • 2013
  • 본 연구에서는 변조전달함수(Modulation transfer function, MTF)를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능을 평가하여 컴퓨터 방사선영상 획득의 기초자료로 제시하고자 하였다. 본 실험에서는 $100{\mu}mm$ 픽셀의 영상판을 이용하여 엣지법의 MTF를 측정하였다. 방사선 선질은 IEC 61267에서 권고하고 있는 RQA5를 이용하였다. X-선이 조사된 영상판은 감도 노출 분류를 50, 100, 200, 300, 400, 600, 800, 1200으로 각각 설정한 후 디지털 영상화하였다. 최종 획득된 영상들은 공인된 영상분석 프로그램인 image J와 Origin 8.0을 이용하여 MTF 50%와 10%를 구하여 평가하였다. 그 결과 감도 노출 분류 200에서 가장 우수한 MTF 50%($1.979{\pm}0.114lp/mm$)와 MTF 10%($3.932{\pm}0.041$)의 공간주파수를 구하였다. 따라서 골절 등과 같이 높은 공간분해능을 요구하는 질병진단에 유용할 것으로 사료된다.

The development of a ship's network monitoring system using SNMP based on standard IEC 61162-460

  • Wu, Zu-Xin;Rind, Sobia;Yu, Yung-Ho;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권10호
    • /
    • pp.906-915
    • /
    • 2016
  • In this study, a network monitoring system, including a secure 460-Network and a 460-Gateway, is designed and developed according with the requirements of the IEC (International Electro-Technical Commission) 61162-460 network standard for the safety and security of networks on board ships. At present, internal or external unauthorized access to or malicious attack on a ship's on board systems are possible threats to the safe operation of a ship's network. To secure the ship's network, a 460-Network was designed and implemented by using a 460-Switch, 460-Nodes, and a 460-Gateway that contains firewalls and a DMZ (Demilitarized Zone) with various application servers. In addition, a 460-firewall was used to block all traffic from unauthorized networks. 460-NMS (Network Monitoring System) is a network-monitoring software application that was developed by using an simple network management protocol (SNMP) SharpNet library with the .Net 4.5 framework and a backhand SQLite database management system, which is used to manage network information. 460-NMS receives network information from a 460-Switch by utilizing SNMP, SNMP Trap, and Syslog. 460-NMS monitors the 460-Network load, traffic flow, current network status, network failure, and unknown devices connected to the network. It notifies the network administrator via alarms, notifications, or warnings in case any network problem occurs. Once developed, 460-NMS was tested both in a laboratory environment and for a real ship network that had been installed by the manufacturer and was confirmed to comply with the IEC 61162-460 requirements. Network safety and security issues onboard ships could be solved by designing a secure 460-Network along with a 460-Gateway and by constantly monitoring the 460-Network according to the requirements of the IEC 61162-460 network standard.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가 (Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).