• Title/Summary/Keyword: Internal-external control

Search Result 762, Processing Time 0.021 seconds

An Empirical Study on Key Success Factors of Company Informatization and Informatization Performance Determinants - Focused on SER-M Framework - (기업 정보화 핵심 성공요인과 정보화 성과 결정요인에 관한 실증 연구 - SER-M Framework을 중심으로 -)

  • Choi, Hae-Lyong;Gu, Ja-Won
    • Management & Information Systems Review
    • /
    • v.36 no.2
    • /
    • pp.277-306
    • /
    • 2017
  • Most past studies on the Critical Success Factors of Company Informatization focused on the completeness of Informatization and its financial effect, and there have not been enough studies on whether a company's management strategies can be supported by establishing Informatization direction. This implies that there must be verification on the followings; whether Informatization focuses on steering the implementation of management strategies, what correlation there are between major mechanism factors and Informatization performance. This also implies that there must be a new study to re-interpret the existing success factors of Informatization into strategic management paradigm. The purpose of this study is to empirically verify the influence of subject, environment, resource, and mechanism factors on informatization achievement, and to analyze the differences in influence of informatization success factors on informatization achievement depending on domestic large corporations and SMEs. This study presented the verification results for seven research hypotheses. It was confirmed through empirical analysis that securing resource factor was significant in informatization performance and that all sub-factors of learning mechanism and coordination mechanism were also significant in enterprise informatization achievement. In addition, it was confirmed through the control effect analysis depending on enterprise size that the differences in informatization performance of large corporations and SMEs are due to support environment factor, learning mechanism, and selection mechanism. The implications of this study are as follows: First, the significance of mechanism factors such as learning, internal coordination, and external coordination are relatively higher than other factors in informatization achievement. Secondly, informatization success factors that SMEs must focus on achieving are presented by analyzing the differences on informatization achievement of large corporations and SMEs. Third, since empirical research for informatization success mechanism factors not covered empirically in the prior research was directly progressed, it is thought that it could provide a comprehensive understanding for mechanism factors. In addition, this study is thought to provide a practical contribution that can be applied to other industrial areas and enterprises.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.