• 제목/요약/키워드: Internal target volume

검색결과 64건 처리시간 0.028초

웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발 (Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging)

  • 안미숙;한용희
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Predictive factors of symptomatic radiation pneumonitis in primary and metastatic lung tumors treated with stereotactic ablative body radiotherapy

  • Kim, Kangpyo;Lee, Jeongshim;Cho, Yeona;Chung, Seung Yeun;Lee, Jason Joon Bock;Lee, Chang Geol;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • 제35권2호
    • /
    • pp.163-171
    • /
    • 2017
  • Purpose: Although stereotactic ablative body radiotherapy (SABR) is widely used therapeutic technique, predictive factors of radiation pneumonitis (RP) after SABR remain undefined. We aimed to investigate the predictive factors affecting RP in patients with primary or metastatic lung tumors who received SABR. Materials and Methods: From 2012 to 2015, we reviewed 59 patients with 72 primary or metastatic lung tumors treated with SABR, and performed analyses of clinical and dosimetric variables related to symptomatic RP. SABR was delivered as 45-60 Gy in 3-4 fractions, which were over 100 Gy in BED when the ${\alpha}/{\beta}$ value was assumed to be 10. Tumor volume and other various dose volume factors were analyzed using median value as a cutoff value. RP was graded per the Common Terminology Criteria for Adverse Events v4.03. Results: At the median follow-up period of 11 months, symptomatic RP was observed in 13 lesions (12 patients, 18.1%), including grade 2 RP in 11 lesions and grade 3 in 2 lesions. Patients with planning target volume (PTV) of ${\leq}14.35mL$ had significantly lower rates of symptomatic RP when compared to others (8.6% vs. 27%; p = 0.048). Rates of symptomatic RP in patients with internal gross tumor volume (iGTV) >4.21 mL were higher than with ${\leq}4.21mL$ (29.7% vs. 6.1%; p = 0.017). Conclusions: The incidence of symptomatic RP following treatment with SABR was acceptable with grade 2 RP being observed in most patients. iGTV over 4.21 mL and PTV of over 14.35 mL were significant predictive factors related to symptomatic RP.

Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

  • Choi, Euncheol;Kim, Jae Ho;Kim, Ok Bae;Byun, Sang Jun;Kim, Jin Hee;Oh, Young Kee
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.227-234
    • /
    • 2018
  • Purpose: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. Materials and Methods: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses of the actual 3D and 2D ICBT plans among patients grouped according to six anatomical variations: differences in a small-bowel V2Gy, small bowel circumference, the direction of bladder distension, bladder volume, sigmoid V3.5Gy, and sigmoid circumference. Seven dose parameters were measured in line with the EMBRACE recommendations. Results: In terms of bladder volume, the bladder and small-bowel D2cc values were lower in the 150-250 mL bladder volume subgroup; and the rectum, sigmoid, and bladder D2mL values were all lower in the >250 mL subgroup, for 3D vs. 2D ICBT. In the sigmoid V3.5Gy >2 mL subgroup, the sigmoid and bladder D2mL values were significantly lower for 3D than 2D ICBT. The bladder D2mL value was also significantly lower for 3D ICBT, as reflected by the sigmoid circumference. In patients with a small bowel V2.0Gy >10 mL or small bowel circumference >15%, most dose parameters were significantly lower for 3D than 2D ICBT. The bladder distension direction did not significantly affect the doses. Conclusion: Compared to 2D ICBT, a greater bladder volume can reduce the internal 3D ICBT organ dose without affecting the target dose.

RNA Modification and Its Implication in Plant Pathogenic Fungi

  • Jeon, Junhyun;Lee, Song Hee
    • The Plant Pathology Journal
    • /
    • 제37권6호
    • /
    • pp.505-511
    • /
    • 2021
  • Interaction of a pathogen with its host plant requires both flexibility and rapid shift in gene expression programs in response to environmental cues associated with host cells. Recently, a growing volume of data on the diversity and ubiquity of internal RNA modifications has led to the realization that such modifications are highly dynamic and yet evolutionarily conserved system. This hints at these RNA modifications being an additional regulatory layer for genetic information, culminating in epitranscriptome concept. In plant pathogenic fungi, however, the presence and the biological roles of RNA modifications are largely unknown. Here we delineate types of RNA modifications, and provide examples demonstrating roles of such modifications in biology of filamentous fungi including fungal pathogens. We also discuss the possibility that RNA modification systems in fungal pathogens could be a prospective target for new agrochemicals.

SWMM을 이용한 도시지역 내수침수 취약성 평가 (A study of Assessment for Internal Inundation Vulnerability in Urban Area using SWMM)

  • 손태석;강동호;장종경;신현석
    • 한국방재학회 논문집
    • /
    • 제10권4호
    • /
    • pp.105-117
    • /
    • 2010
  • 도시지역의 지형적인 저지대, 배수능력 부족, 하수역류 노면배수 등은 내수침수의 주요원인이며 최근 기후변화에 따른 강우증가, 경제발전과 인구증가에 따른 급격한 도시화, 도시지역 불투수 면적의 증가는 도시지역 내수침수의 위험성을 가중시키고 있다. 이에 본 연구는 도시지역의 내수침수 위험도 분석을 위하여 부산시 대표 도시하천인 온천천을 대상유역으로 하여 SWMM 모형을 구축하고 각 소유역의 대표 우수관을 선정하여 강우에 의한 도시하천 내수침수 위험 취약성 분석을 실시하였다. 침수위험 취약성 분석을 위하여 SWMM모형 내 관거의 용량을 나타내는 지표인 Capacity를 이용하였으며 Capacity에 따라 내수침수 위험도를 1단계에서 4단계로 구분하였다. 내수침수 위험도 분석은 2009년 7월 7일 부산시 집중호우에 의한 실제침수 구역과 SWMM 모형의 모의에 의한 결과를 비교 분석하여 모형의 타당성을 입증하고 부산지점 빈도별(10, 20, 50, 100년) 지속시간별(6, 12, 18, 24hr) 확률강우량을 입력하여 내수침수 위험 취약성 분석을 실시하였다. 본 연구의 결과는 도시지역의 내수침수 예경보 및 내수침수 취약지구 선정에 활용가능할 것이다.

The Upper Ascending Reticular Activating System between Intralaminar Thalamic Nuclei and Cerebral Cortex in the Human Brain

  • Jang, Sungho;Kwak, Soyoung
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.109-114
    • /
    • 2017
  • Purpose: The ascending reticular activating system (ARAS) is responsible for regulation of consciousness. In this study, using diffusion tensor imaging (DTI), we attempted to reconstruct the thalamocortical projections between the intralaminar thalamic nuclei and the frontoparietal cortex in normal subjects. Methods: DTI data were acquired in 24 healthy subjects and eight kinds of thalamocortical projections were reconstructed: the seed region of interest (ROI) - the intralaminar thalamic nuclei and the eight target ROIs - the medial prefrontal cortex, dorsolateral prefrontal cortex, ventrolateral prefrontal cortex, orbitofrontal cortex, premotor cortex, primary motor cortex, primary somatosensory cortex, and posterior parietal cortex. Results: The eight thalamocortical projections were reconstructed in each hemisphere and the pathways were visualized: projections to the prefrontal cortex ascended through the anterior limb and genu of the internal capsule and anterior corona radiata. Projections to the premotor cortex passed through the genu and posterior limb of the internal capsule and middle corona radiata; in contrast, projections to the primary motor cortex, primary somatosensory cortex, and posterior parietal cortex ascended through the posterior limb of the internal capsule. No significant difference in fractional anisotropy, mean diffusivity, and fiber volume of all reconstructed thalamocortical projections was observed between the right and left hemispheres (p>0.05). Conclusion: We reconstructed the thalamocortical projections between the intralaminar thalamic nuclei and the frontoparietal cortex in normal subjects. We believe that our findings would be useful to clinicians involved in the care of patients with impaired consciousness and for researchers in studies of the ARAS.

간암의 방사선치료 시 호흡운동 감소장치(respiratory motion reduction device, RRD)의 유용성에 관한 연구 (Use of Respiratory Motion Reduction Device (RRD) in Treatment of Hepatoma)

  • 이석;성진실;김용배;조광환;김주호;장세경;권수일;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제19권4호
    • /
    • pp.319-326
    • /
    • 2001
  • 목적 : 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하는 영역으로 조사 체적이 증가된다. 이로 인하여 방사선 독성 및 정상조직 선량이 증가되며, 호흡으로 인한 환자자세의 변화로 인해 종양의 정확한 위치파악이 어렵게 된다. 본 연구에서는 호흡에 따른 장기 움직임 유형을 분석하여 호흡에 의한 장기의 움직임을 최소화 할 수 있는 호흡운동 감소장치를 고안하고 방사선치료 시 호흡운동 감소장치의 유용성을 평가해 보고자 하였다. 대상 및 방법 : 간암환자 10명을 대상으로 하여 MeV-Green과 벨트, 스티로폼판 등을 사용하여 호흡운동감소장치(respiratory motion reduction device, RRD)를 제작하였다. 내부장기의 이동정도는 모의치료 시에 관찰된 횡경막의 이동 정도로 평가하였으며 앙와위와 복와위 및 RRD의 사용 시 이동정도를 쏠아보았고, 각각의 경우에서 이동정도를 고려하여 방사선치료계획을 수립하였다. 선량체적 히스토그램(dose-volume histogram, DVH)을 통해서 전체 간 용적 중 처방선량의 $50\%$가 조사되는 정상간 용적을 구하였다. 결과 : 호흡에 따른 횡경막의 평균이동거리는 앙와위 자세에서 $16{\pm}1.9\;mm$ 이었고, 복와위 자세에서는 $12{\pm}1.9mm$임을 알 수 있었다. 복와위 자세에서 본원에서 자체 제작한 RRD를 사용한 경우에는 $5{\pm}1.4\;mm$으로 감소되었고, 벨트 고정장치의 추가 사용 시에는 $3{\pm}0.9\;mm$으로 감소하여 총 9 mm 감소함을 알 수 있었다. 방사선치료계획에 따른 DVH에서 처방선량의 $50\%$가 조사되는 정상간의 용적은 호흡운동감소장치를 사용하지 않은 경우에 앙와위 자세에서 $43.7\%$, 복와위 자세에서 $40\%$ 이었고, 호흡운동 감소장치를 사용한 경우에 복와위 자세에서 $30.7\%$, 여기에 벨트 고정장치를 추가 사용하였을 경우에는 $21\%$로서 전체 간 용적 중 방사선에 조사되는 정상 간 용적은 최대 $22.7\%$ 감소됨을 알 수 있었다. 결론 : 호흡에 따른 내부장기의 움직임을 최소화 할 수 있는 RRD를 사용하여 정상조직에 불필요하게 조사되는 방사선을 감소시킬 수 있었다.

  • PDF

비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가 (Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient)

  • 박소연;안종호;서정민;김영일;김진만;최병기;표홍렬;송기원
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.123-135
    • /
    • 2012
  • 목 적: 비소세포성 폐암 환자의 호흡 조절 방사선 치료 시 호흡에 의한 종양의 움직임을 최소화하는 것이 필수적이다. 이에 본 연구에서는 자유호흡 주기와 제한호흡 주기를 각각 적용한 치료 계획을 비교, 분석하여 제한 호흡 주기의 유용성을 평가하고자 한다. 대상 및 방법: 2011년 4월부터 12월까지 비소세포성 폐암 환자 9명(tumor n=10)을 대상으로 환자에게 평소의 호흡주기를 바탕으로 측정한 '자유호흡 주기'와 의도적으로 줄인 '제한호흡 주기'를 '신호모니터-호흡(guided-breathing)'법을 사용하여 각각 훈련을 실시한 후 RPM과 4차원 전산화 단층촬영 모의치료기를 이용해 치료계획용 4D CT를 실시하여 총 10개의 호흡 위상(respiration phase)별 CT 영상을 획득하였다. 각 호흡 주기의 CT 영상에 관측자 두 명이 각각 설정한 육안적 종양체적(Gross Tumor Volume, GTV)과 내부표적체적(Internal Target Volume, ITV)부피를 측정, 비교하였고 들숨(end-inspiration, EI)인 0%와 날숨(end-exhalation, EE)인 50% 위상에서의 center of mass (COM)를 측정하여 종양 움직임의 진폭을 측정했다. 또한 관측자 두명이 각각 두 호흡 주기를 적용한 치료계획을 수립하였고 정상 폐 평균선량(mean dose to normal lung, MDTNL)과 정상 폐 용적의 정상조직합병증확률(normal tissue complication probability, NTCP)을 비교, 분석하였으며 측정된 자료의 정량적 평가를 위해 통계 분석을 실시했다. 결 과: 관측자 두 명의 '제한호흡 주기'를 적용한 치료 계획을 분석한 결과 '자유호흡 주기'에 비해 종양의 3D 방향 움직임이 관측자 1의 경우 38.75%, 관측자 2의 경우 41.10%의 감소율을 보였고 GTV와 ITV의 부피를 측정, 비교한 결과 GTV의 부피는 관측자 1의 경우 $14.96{\pm}9.44%$, 관측자 2의 경우 $19.86{\pm}10.62%$, ITV의 부피는 관측자 1의 경우 $8.91{\pm}5.91%$, 관측자 2의 경우 $15.52{\pm}9.01%$의 감소율을 보였으며 MDTNL과 NTCP를 분석, 비교한 결과 MDTNL은 관측자 1의 경우 $3.98{\pm}5.62%$, 관측자 2의 경우 $7.62{\pm}10.29%$의 감소율을, NTCP의 경우 관측자 1의 결과 $21.70{\pm}28.27%$, 관측자 2의 결과 $37.83{\pm}49.93%$의 감소율을 나타냈다. 또한 두 관측자의 결과 값의 상관관계를 분석한 결과 '자유호흡 주기'에서는 관측자간의 유의한 차이를 보이는 데 비해 '제한호흡 주기'에서는 관측자간의 차이가 없는 감소율을 보였다. 결 론: '자유호흡 주기'에 비해 '제한호흡 주기'를 적용한 치료 계획에서 평가인자들의 상대적인 감소를 나타내어 비소세포성 폐암 환자의 호흡 조절 방사선 치료 시 '제한호흡 주기'의 유용성 및 타당성을 확인할 수 있었다.

  • PDF

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 - (Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.