• Title/Summary/Keyword: Internal radiation dose

Search Result 341, Processing Time 0.027 seconds

Dosimetry and Medical Internal Radiation Dose of Re-188-DTPA for Endovascular Balloon Brachytherapy Against Restenosis after Coronary Angioplasty (혈관성형술 후 재협착 방지 치료에 사용하기 위한 원통형 풍선 Re-188-DTPA의 선량 분포와 내부피폭 선량)

  • Lee, Jin;Lee, Dong-Soo;Shin, Seung-Ae;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.163-171
    • /
    • 1999
  • Purpose: Liquid beta emitter filled in angioplasty balloon could be used to perform endovascular balloon brachytherapy to prevent coronary artery restenosis. We investigated the dosimetry for Re-188-DTPA liquid-filled balloon and medical internal radiation dosimetry in case of balloon leakage. Materials and Methods: We estimated radiation dose from an angioplasty balloon (20 mm length, 3 mm diameter cylinder) to the adjacent vessel wall using Monte Carlo EGS4 code. We obtained time-activity curves of kidneys in normal dog and calculated $T_{max},\;T_{1/2}$. Using MIRDOSE3 program, we estimated absorbed doses to the major organs (kidneys, bladder) and the whole body when we assumed that balloon leaked all the isotope contained. Results: The radiation dose was 17.5 Gy at the balloon surface when we applied 3,700 MBq/ml of Re-188 for 100 seconds, Fifty percent of the energy deposited within 1 mm from the balloon surface. The estimated internal dose to the whole body was 0.005 mGy/MBq and 18.5 mGy for the spillage of 3,700 MBq of Re-188. Conclusion: We suggest that Re-188-DTPA can be used for endovascular balloon brachytherapy to inhibit coronary artery restenosis after angioplasty with tolerable whole body radiation dose in case of balloon rupture.

  • PDF

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Reduced-dose whole-brain radiotherapy with tumor bed boost after upfront high-dose methotrexate for primary central nervous system lymphoma

  • Lee, Tae Hoon;Lee, Joo Ho;Chang, Ji Hyun;Ye, Sung-Joon;Kim, Tae Min;Park, Chul-Kee;Kim, Il Han;Kim, Byoung Hyuck;Wee, Chan Woo
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.35-43
    • /
    • 2020
  • Purpose: This retrospective study compares higher-dose whole-brain radiotherapy (hdWBRT) with reduced-dose WBRT (rdWBRT) in terms of clinical efficacy and toxicity profile in patients treated for primary central nervous system lymphoma (PCNSL). Materials and Methods: Radiotherapy followed by high-dose methotrexate (HD-MTX)-based chemotherapy was administered to immunocompetent patients with histologically confirmed PCNSL between 2000 and 2016. Response to chemotherapy was taken into account when prescribing the radiation dose to the whole brain and primary tumor bed. The whole brain dose was ≤23.4 Gy for rdWBRT (n = 20) and >23.4 Gy for hdWBRT (n = 68). Patients manifesting cognitive disturbance, memory impairment and dysarthria were considered to have neurotoxicity. A median follow-up was 3.62 years. Results: The 3-year overall survival (OS) and progression-free survival (PFS) were 70.0% and 48.9% with rdWBRT, and 63.2% and 43.2% with hdWBRT. The 3-year OS and PFS among patients with partial response (n = 45) after chemotherapy were 77.8% and 53.3% with rdWBRT, and 58.3% and 45.8% with hdWBRT (p > 0.05). Among patients with complete response achieved during follow-up, the 3-year freedom from neurotoxicity (FFNT) rate was 94.1% with rdWBRT and 62.4% with hdWBRT. Among patients aged ≥60 years, the 3-year FFNT rate was 87.5% with rdWBRT and 39.1% with hdWBRT (p = 0.49). Neurotoxicity was not observed after rdWBRT in patients aged below 60 years. Conclusion: rdWBRT with tumor bed boost combined with upfront HD-MTX is less neurotoxic and results in effective survival as higher-dose radiotherapy even in partial response after chemotherapy.

THE IMPORTANCE OF PATIENT-SPECIFIC DOSE CALCULATIONS IN NUCLEAR MEDICINE

  • Stabin, Michael G.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.527-532
    • /
    • 2008
  • As therapeutic uses of radionuclides in nuclear medicine increases, the use of patient-specific methods for calculation of radiation dose becomes more important. In this manuscript basic methods and resources for internal dose calculations are outlined, with a focus on how current changes and advances are making more accurate and detailed, patient-individualized dose calculations possible. Most current resources make use of standardized models of the human body representing median individuals, but the use of image-based and more realistic models will soon take their place, and will permit adjustments to represent individual patients and tailor therapy planning uniquely for each subject.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Analysis of Exposure Pathways and the Relative Importance of Radionuclides to Radiation Exposure in the Case of a Severe Accident of a Nuclear Power Plant (원전 중대사고시 피폭경로 및 핵종의 방사선 피폭에 대한 상대적 중요도 해석)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.209-221
    • /
    • 1994
  • In the case of a severe accident of a nuclear power plant, the whole body dose and the relative importance of the radionuclides during the lifetime of an exposed person were estimated for each exposure pathway with distances from the release point. The external exposure pathways due to immersion of radioactive cloud and deposition of radioactive materials on the ground, and the internal exposure pathways due to inhalation and ingestion of contaminated foodstuffs were considered. The effects due to the ingestion of contaminated foodstuffs were estimated considering the variation of radioactive concentration in the foodstuffs according to deposition time and elapsed time after deposition using a dynamic ingestion pathway model applicable to Korean environment, named 'KORFOOD'. As the results up to 80 km from the release point, the effects due to ingestion of contaminated foodstuffs showed the highest contribution to total exposure dose. The contribution of I isotopes was the highest in the case of the external dose due to immersion of radioactive cloud and internal dose due to inhalation. The contribution of Cs isotopes was highest in the case of the external dose due to deposition of radioactive materials on the ground. In the case of the internal dose due to ingestion of contaminated foodstuffs, Cs deposition in summer and Sr deposition in winter, respectively, were the most dominant radionuclide to whole body.

  • PDF

Deep inspiration breath-hold (DIBH) 적용한 림프절이 포함된 왼편 유방암의 방사선 치료계획에 따른 주변 장기 선량 평가

  • Jeong, Da-Lee;Gang, Hyo-Seok;Choe, Byeong-Jun;Park, Sang-Jun;Lee, Geon-Ho;Lee, Du-Sang;An, Min-U;Jeon, Myeong-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • Purpose: On the left side, breast cancer patients have more side effects than those on the right side because of unnecessary doses in normal organs such as heart and lung. DIBH is performed to reduce this. To evaluate the dose of peripheral organs in the left breast cancer including supraclavicular lymph nodes and internal mammary lymph nodes according to the treatment planning method of Conventional Radiation Therapy, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy. Materials and Methods: We performed CT-simulation using free breathing and deep inspiration breath-hold technique for 8 patients including left supraclavicular lymph nodes and internal mammary lymph nodes. Based on the acquired CT images, the contour of the body is drawn and the convention is performed so that $95%{\leftarrow}PTV$, $Dmax{\leftarrow}110%$. Conventional Radiation Therapy used a one portal technique on the supraclavicular lymph node and used a field in field technique tangential beam on the breast. Intensity Modulated Radiation Therapy was composed of 7 static fields. Volumetric Modulated Arc Therapy was planned using 2 ARC with a turning radius of $290^{\circ}$ to $179^{\circ}$. The peripheral normal organs dose was analyzed by referring to the dose volume of Eclipse. Results: By applying the deep inspiration breath-hold technique, the mean interval between the heart and chest wall increased $1.6{\pm}0.6cm$. The mean dose of lung was $19.2{\pm}1.0Gy$, which was the smallest value in Intensity Modulated Radiation Therapy. The V30 (%) of the heart was $2.0{\pm}1.9$, which was the smallest value in Intensity Modulated Radiation Therapy. In the left anterior descending coronary artery, the dose was $25.4{\pm}5.4Gy$, which was the smallest in Intensity Modulated Radiation Therapy. The maximum dose value of the Right breast was $29.7{\pm}4.3Gy$ at Intensity Modulated Radiation Therapy. Conclusion: When comparing the values of surrounding normal organs, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy were applicable values for treatment. Among them, Intensity Modulated Radiation Therapy is considered to be a suitable treatment planning method.

  • PDF

A Study on the X-ray Image Reading of Radiological Dispersal Device (방사능 폭발물의 X-ray 영상판독에 관한 연구)

  • Geun-Woo Jeong;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.

A Comparison between the Performance Degradation of 3T APS due to Radiation Exposure and the Expected Internal Damage via Monte-Carlo Simulation (방사선 노출에 따른 3T APS 성능 감소와 몬테카를로 시뮬레이션을 통한 픽셀 내부 결함의 비교분석)

  • Kim, Giyoon;Kim, Myungsoo;Lim, Kyungtaek;Lee, Eunjung;Kim, Chankyu;Park, Jonghwan;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • The trend of x-ray image sensor has been evolved from an amorphous silicon sensor to a crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor), is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a Select Transistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequency of exposure to radiation increases, the quality of the imaging device dramatically decreases. The most well known effects of a X-ray CIS due to the radiation damage are increments in the reset voltage and dark currents. In this study, a pixel array of a X-ray CIS was made of $20{\times}20pixels$ and this pixel array was exposed to a high radiation dose. The radiation source was Co-60 and the total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated the small pixel array to get the increments data of the reset voltage and the dark currents. Also, we simulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. From the comparison of actual data and simulation data, the most affected location could be determined and the cause of the increments of the reset voltage and dark current could be found.

STUDIES ON THE BIOLOGICAL HALF-LIVES OF TRITIUM RELEASED AT WOLSONG NUCLEAR POWER PLANTS

  • Kim, H.G.;Eum, H.M.;Cha, S.C.;Kim, M.C.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.139-142
    • /
    • 2001
  • The one of important parameter involved in the calculation of internal radiation dose to the human body is the biological half-life of the radionuclide. The biological half-life is population specific and may differ from one population group to another. So the effective half-life of tritium exposure based on urinal bioassay measurement of Wolsong Nuclear Power Plants was investigated and studied.

  • PDF