• Title/Summary/Keyword: Internal pressure

Search Result 2,762, Processing Time 0.024 seconds

Study on Bursting Prediction of Rectangular Battery Case with V-Notch (직사각형 전지 케이스의 V-notch부 터짐 예측에 관한 연구)

  • Kim, S.M.;Song, W.J.;Ku, T.W.;Kim, J.;Kang, B.S.
    • Transactions of Materials Processing
    • /
    • v.18 no.1
    • /
    • pp.59-66
    • /
    • 2009
  • In this study, V-notch part has been considered as one of safety components in rectangular cup used for mobile device. This kind of safety component in rectangular cup with the V-notch part, which controls adequately the increased internal pressure in the rectangular cup, plays an important role to prevent the explosion from the excessive internal pressure. The protecting mechanism on the mobile device against the explosion is that a series of fracture on the V-notch part at the critical internal pressure level occurs. Therefore, it is very crucial to estimate accurately the working pressure range of the safety device. Relationship between the working internal pressure and fracture phenomenon at V-Notch part was investigated through numerical analysis using ductile fracture criteria. Integral value, I, of the used ductile fracture criteria was calculated from effective stress and strain, and then the bursting pressure of the V-notch part was extracted. Comparisons between the estimated and experimental results show that this systematic approach to predict bursting pressure using the ductile fracture criteria gives fairly good agreements.

Shape Change Analysis of a Small Propane Container by Pressure Test (소형프로판용기 내압시험을 통한 용기의 형상변화 분석)

  • Lee, Jong-Sang;Jang, Kap-Man;Lee, Yoon Hyoung;Yim, Sang-Sik;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this study, it is analyzed that a change in the shape of small propane containers made of STS304 when increasing of internal pressure. When internal pressure of a small propane container increased, bottom of end plate is convexly changed. This test is applied to a water bath pressure test to analyze the characteristics of the container. Water bath is able to analyze relationship between internal pressure and volume. In result, shape change section is confirmed because bottom of end plate is convexly changed. In addition, this section tend to decrease internal pressure because a volume increment increase out of proportion to pressure. The results of this study are expected to contribute to improving the safety of the pressure vessel, as well as various small propane container.

Experimental Study on the Characteristics of Pressure Variation of KTX Passing Through Tunnel

  • Nam, Seong-Won
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.169-174
    • /
    • 2008
  • Experimental study has been conducted to clarify the internal and external pressure variation characteristics for KTX(Korea Train eXpress) passing through tunnel. Abrupt pressure variation gives rise to the ear-discomfort for passenger and fatigue for car body. In this study, the internal and external pressure variation are measured by using KTX real train experiment and on-board portable data acquisition system in Gyeongbu high speed commercial line. The tunnels from 200 m to 4000 m in length are chosen for the investigation of tunnel length effects. From the results of experiment, the internal pressure variation rate for all the test tunnels is lower than the standard criteria of 200 Pa/s. And, the critical tunnel lengths for pressure wave pattern are classified into 7 groups by using the theoretical L-t diagram analysis.

  • PDF

Elastic-Plastic Stress Analysis and Fatigue Lifetime Prediction of Cross-Bores in Autofrettaged Pressure Vessels

  • Koh, Seung-Kee
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.935-946
    • /
    • 2000
  • Elastic-plastic stress analysis has been performed to evaluate the fatigue life of an autofrettaged pressure vessel containing cross-bores subjected to pulsating internal pressure of 200 MPa. Finite element analyses were used to calculate the residual and operating stress distributions of the pressure vessel due to the autofrettage process and pulsating internal pressure, respectively. Theoretical stress concentration factors of 3.06, 2.58, and 2.64 were obtained at the cross-bore of the pressure vessel due to internal pressure, 50%, and 100% autofrettage loadings, respectively. Local stresses and local strains determined from the elastic-plastic finite element analysis were employed to calculate the failure location and fatigue life of the pressure vessel with radial cross-bores, incorporating the low-cycle fatigue properties of the pressure vessel steel and fatigue damage parameters. Increase in the amount of overstrain by autofrettage process moved the crack initiation location from the inner radius toward a mid-wall, and extended the crack initiation life. Predicted fatigue life of the fully autofrettaged pressure vessel with cross-bores increased about 50%, compared to the unautofrettaged pressure vessel. At the autofrettage level higher than 50%, the failure location and fatigue life of the pressure vessel were not significantly influenced by the autofrettage level.

  • PDF

The Relationship between Pulse Wave Velocity (PWV) and Risk Factors of Cardiovascular Disease including Serum Lipid Values (Pulse Wave Velocity(PWV)와 혈청지질수치를 포함한 심혈관 질환 위험 요인들과의 상관관계 연구)

  • Jeong, Seung-Hwan;Um, Eun-Jin;Park, Woo-Rham;Lee, Beom-Jun;Na, Byung-Jo
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.525-533
    • /
    • 2009
  • Objectives : There are lots of reports that cardiovascular disease, including hypertension, cerebro-vascular accident, and coronary heart disease, is related to atherosclerotic changes. Increased serum levels of lipids could play a role in these changes. This study aimed to investigate the relationship between PWV and risk factors of cardiovascular disease, including serum lipid values. Methods : This study included 261 subjects ($49.32{\pm}11.79$ years, 112 male) who underwent PWV and serum lipid evaluation. We investigated the correlation between serum lipid values, blood pressure, body mass index (EMI) and PWV. Pearson's correlation and partial correlation analysis were applied to examine the relationship between PWV and risk factors of cardiovascular disease. Results : Serum triglyceride, total cholesterol, systolic blood pressure, and diastolic blood pressure were significantly correlated with PWV. Partial correlation coefficient adjusted by age yielded significant correlation between serum triglyceride, systolic blood pressure, diastolic blood pressure and PWV. Conclusion : In this study, it seems that there are significant relationships between PWV, triglyceride and blood pressure. We could suggest that PWV might have some relationships with Dam-eum and blood stasis in oriental theory.

  • PDF

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

A Clinical Observation of two cases of Pressure Sore complicated by cerebrovascular diseases (뇌혈관질환 후 발생한 욕창에 대한 치험 2례)

  • Lee, Yun-Jae;Lee, Seong-Kyun;Kim, Jeong-Hwan;Ji, Dong-Hee;Song, Cheol-Min;Chang, Tong-Young;Yun, Jong-Min;Son, Ji-Young;Shin, Sun-Ho;Rhim, Eun-Kyung
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.426-432
    • /
    • 2004
  • Pressure sore(decubitus ulcer) is the an ulceration and necrosis of the skin and underlying tissue usually occuring on a bony prominence of the body after prolonged or repeated pressure. This study was designed to evaluate the effects of an oriental medicine(Sipjeondaebo-tang) on pressure sores complicated by cerebrovascular diseases. Methods: As For treatment, we used Sipjeondaebo-tang. Results: Both patients were treated with Sipjeondaebo-tang. After treatment, the pressure sores of two patients were improved. Conclusions: This study suggests that Sipjeondaebo-tang is effective in treatment of pressure sores(decubitus ulcer) complicated by cerebrovascular diseases.

  • PDF

An Engineering Method for Non-Linear Fracture Mechanics Analysis of Circumferential Through-Wall Cracked Pipes Under Internal Pressure (내압이 작용하는 원주방향 관통균열 배관의 비선형 파괴역학 해석법)

  • Huh, Nam-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1099-1106
    • /
    • 2002
  • This paper provides engineering J-integral and crack opening displacement (COD) estimation equations for circumferential through-wall cracked pipes under internal pressure and under combined internal pressure and bending. Based on selected 3-D finite element calculations for the circumferential through-wall cracked pipes under internal pressure using the idealized power law materials, the elastic and plastic influence functions for fully plastic J-integral and COD solutions are found as a function of the normalized crack length and the mean radius-to-thickness ratio. These developed GE/EPRI-type solutions are then re-formulated based on the enhanced reference stress method. Such re-formulation not only provides simpler equations for J-integral and COD estimations, but also can be easily extended to combined internal pressure and bending. The proposed equations are compared with elastic-plastic finite element results using actual stress-strain data, which shows overall excellent agreement.

Failure Criterion of Straight Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 직관의 파손 기준)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.76-83
    • /
    • 2014
  • This study was carried out an experimental and finite element analysis on the fracture behavior of straight pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion/corrosion metal loss. The configurations of the eroded area has an eroded ratio of d/t=0.80~0.92 and an eroded length of l=25, 50 and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using the finite element method, which is able to accurately simulate failure behaviors. In regards to the relation ship between pressure and eroded ratio, the criterion that can be used safely under operating pressure and design pressure were obtained from this calculation. The results of this calculation were in relatively good agreement with that of the experiment.

Pretest analysis of a prestressed concrete containment 1:3.2 scale model under thermal-pressure coupling conditions

  • Qingyu Yang;Jiachuan Yan;Feng Fan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2069-2087
    • /
    • 2023
  • In nuclear power plant (NPP) accidents, the containment is subject to high temperatures and high internal pressures, which may further trigger serious chain accidents such as core meltdown and hydrogen explosion, resulting in a significantly higher accident level. Therefore, studying the mechanical performance of a containment under high temperature and high internal pressure is relevant to the safety of NPPs. Based on similarity principles, the 1:3.2 scale model of a prestressed concrete containment vessel (PCCV) of a NPP was designed. The loading method, which considers the thermal-pressure coupling conditions, was used. The mechanical response of the PCCV was investigated with a simultaneous increase in internal pressure and temperature, and the failure mechanism of the PCCV under thermal-pressure coupling conditions was revealed.