• Title/Summary/Keyword: Internal margin

Search Result 239, Processing Time 0.028 seconds

Micromorphology of Benthic Diatom Species Achnanthes alteragracillima Lange-Bert

  • Lee, Jung Ho
    • Journal of Plant Biology
    • /
    • v.37 no.4
    • /
    • pp.417-420
    • /
    • 1994
  • Morphology of Achnanthes alteragracillima Lange-Bert. was studied with scanning electron microscopy in epilithic samples from the Kwang River (Kwangchun), Kyungsangbuk-Do, Korea. The species was characterized by the external raphe terminal fissure deflecting up to valve margin, the internal raphe proximal endings slightly deflecting to the opposite direction each other and biased hyaline area at the valve pole. It could be distinguished from A. minutissima K tz., closely related species, in having not straight external raphe terminal fissures, and from A. convergens H.Kob. in having a biased hyaline area at the valve pole and not a convergent striae arrangement at the pole of the raphe valve.

  • PDF

Esophageal Basaloid Squamous Carcinoma Treated by Endoscopic Resection and Radiation (내시경 절제술과 방사선 치료로 완치한 식도의 기저양 편평세포암)

  • Kim, Sung Bum;Lee, Si Hyung;Jeong, Da Eun;Kim, Kyeong Ok;Gu, Mi Jin
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.258-261
    • /
    • 2018
  • Esophageal basaloid squamous carcinoma (BSC) is a rare, aggressive variant of squamous cell carcinoma. BSC is usually diagnosed in advanced stage and its prognosis is relatively poor. A 59-year-old male with subepithelial lesion of the esophagus that was incidentally discovered during health promotion examination was referred to our hospital. Esophagogastroduodenoscopy showed a 10-mm bulging mucosa with an intact surface at 34 cm from incisor teeth. Endoscopic ultrasonography revealed a smooth margined homogenous hypoechoic lesion, measuring $11.3{\times}3.9mm$ with a submucosal layer of origin. The patient underwent endoscopic mucosal resection of the subepithelial lesion. Pathologic examination of the resected specimen revealed BSC with involvement of vertical margin by tumor. The patient then underwent radiotherapy, and is doing well without recurrence for 35 months. We report a case of esophageal BSC confined to submucosal layer successfully treated with endoscopic resection followed by radiation.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

The external and internal morphological standard of original plants and herbal states in 2 kinds of Arisaematis Rhizoma (2종 천남성(天南星)의 외부(外部) 및 내부형태(內部形態)에 대한 연구)

  • Kang Jun-Hyug;Yun Ju-Bong;Ju Young-Sung
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.213-232
    • /
    • 2003
  • Objectives : This study was designed to establish a characteristic discrimination of internal and external morphological standard of original plants and herbal states in Arisaema amurense var. serratum $N_{AKAI}$ and A. amurense $M_{AXIM}.$. Methods : In this studies, the external-internal morphological standards were determined by using stereoscope and butanol series. Results : 1. In the external shape of original plant, Arisaema amurense var. serratum $N_{AKAI}$ has high stem, an oval-elliptic leaflet and a serrate leaf margin. But A. amurense $M_{AXIM}$ has a relatively low stem, an upside oval leaflet and no serrate leaf margin. 2. On the herbs character of original plant, Arisaema amurense var. serratum $N_{AKAI}$ is small in height and diameter, but A. amurense $M_{AXIM}$ is relatively large in height and diameter. 3. On the gathered herbs character of original plant, the section of Arisaema amurense var. serratum $N_{AKAI}$ is brightly white, easily spilt and strong scent. But the section of A. amurense $M_{AXIM}$ is thin yellowish brown, not easily spilt and weak scent. Also the grade of gathered herbs, both can be classified by diameter and external scent. 4. In the current herbs character, Korean and Sichuan Province products are irregullar shape and have no scent, Jilin Province products are regular shape. Also, Guangxi Province products are small size and concave in one side, Hebei Province products are irregular size and shape. 5. In internal shape of original plant, epidermal cell of Arisaema amurense var. serratum is very tight. With the except of micro difference in parenchyma cell of cortex, on the whole there are nearly no differences with A. amurense $M_{AXIM}.$ Also, samely in the internal shape, according to collecting sites, epidermis exhibits a lot layer in curving state and secreting duct is developed and vascular bundle and exists between parenchyma cell of cortex. Conclusion : In the future, additional study is needed to distinguish herb and effect between same genus-degree of relatedness.

  • PDF

MARGINAL AND INTERNAL FIT OF CAD/CAM-MANUFACTURED CERAMIC INLAY (CAD/CAM으로 제작된 세라믹 인레이의 변연 및 내면 적합성)

  • Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.618-629
    • /
    • 1998
  • CAD/CAM-fabricated ceramic restorations nowadays are used as alternatives of amlagam and posterior composite resin restorations, especially in the cases of inlay restorations. But the reported results on marginal and internal fit of CAD/CAM-fabricated ceramic inlay have showed considerable difference. In this study, to evaluate the marginal and internal fit of CEREC2-fabricated ceramic inlay restoration and to compare with the fit of gold inlay and amalgam restoration, standardized Class II MO cavities were prepared in forty extracted caries-free human premolars. The teeth with prepared cavities were divided into 4 groups of ten teeth each. In group 1, CEREC2-fabricated ceramic inlays were treated with Scotchbond Multi-Purpose Plus(SMP plus) and cemented with Scotchbond Resin Cement. In group 2, casted gold inlays were cemented in the same method as in group 1. In group 3, casted gold inlays were cemented with zinc-phosphate cement. And in group 4, the prepared cavities were restored with amalgam. Restored teeth were thermocycled, stored in 1% methylene blue for 24 hours, and sectioned faciolingually and mesiodistally using EXAKT. Sectioned surfaces were observed with stereomicroscope and the gaps were measured at 9 points of mesiodistally sectioned surface and 7 points of faciolingually sectioned surface. The measured data were treated by Kruskal-Wallis one way ANOVA and Student-Newman-Keuls test. 1. The differences among measured gaps at each points were statistically significant for 4 experimental groups (P<0.05). 2. There were statistically significant differences in the measured gaps at each points between group 1 and group 2, group 1 and group 3, group 1 and group 4, group 2 and group 4, and group 3 and group 4 (P<0.05). 3. There were not statistically significant differences in the measured gaps at each points between group 2 and group 3 (P>0.05). 4. In the cases of inlay restorations(group 1, group 2, group 3), the gaps at internal line angle(distopulpal, axiogingival, faciopulpal, linguopulpal line angle) had a tendency to increase. In the cases of amalgam restorations(group 4), the gaps at occlusal margin, gingival margin and axiogingival line angle were greater than those at the other parts of cavities. 5. In CEREC2-fabricated ceramic inlays which were treated with Scotchbond Multi-Purpose Plus and cemented with Scotchbond Resin Cement, the mean gaps were $111{\mu}m$ at cavity margins, $168{\mu}m$ at vertical walls of cavities, $225{\mu}m$ at internal line angles and $123{\mu}m$ at cavity floors.

  • PDF

Enthalpy Rise for Pressure Loss of Spacer Grids of Dual Coolant Fuel (이중냉각연료에서 지지격자의 압력손실에 대한 엔탈피 증가)

  • Chun, Kun-Ho;Chun, Tae-Hyun;Shin, Chang-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3473-3478
    • /
    • 2007
  • A dual side cooling annular fuel having internal and external coolant channels has many advantages basically due to low fuel temperature and high DNBR margin, which can make a significant increase of core power density possible. So recently a 12x12 square annular fuel array was proposed for the fuel assembly to be reloaded without structural interference with operating reactors of OPR-1000s. Even through the inherent potential of the annular fuel on the high power density, it may be seriously eroded in the case of a severe unbalanced mass flux split to the internal and external channels in standpoint of DNB. Mass flux split is determined pressure drop characteristics between inner and outer channels. The spacer grids binding fuel array influence greatly the pressure drop in outer channels and the mass flux split. As an important factor of DNB behavior, the enthalpy differences at both channel exits were evaluated using the mass flux splits.

  • PDF

Sensitivity Analysis on the Seismic Responses of the Reactor Structures (원자로구조물의 지진응답 민감도해석)

  • Lee, J. H.;Kim, J. B.;Koo, G. H.;Kim, J. I.;Yoo, B.;Choi, S.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.183-190
    • /
    • 1993
  • The seismic response of the reactor structures depends on the dynamic charact-eristics of the structures and the input earthquake loadings. The stuctural integ-rity of the reactor internal components can be verified by the dynamic response analyses to implement the effects of the design loadings like earthquakes. The sensitivity analyses of the dynamic characteristics for the analytical model of reactor structures considering the possible variations of the stiffnesses of the CSB upper flange and the snubber were performed to improve the dynamic characteri-stics of the structures against seismic loading. And to enhance the structural design margin of the reactor internal components the nonlinear time history analyses were attempted for the modified analytical model, and the results were compared between the reference model and the modified ones.

  • PDF

Patch Reinforcement and Safety Evaluation for Pressure Vessel with Internal Wall Thinning (내부 부식 감육부를 갖는 압력용기의 패치 보강 및 안전성 평가)

  • Song, Tae-Kwang;Chun, Yun-Jae;Myung, Man-Sik;Kim, Yon-Jae;Lee, Tae-Hee;Park, Ji-Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.22-29
    • /
    • 2008
  • This paper provides the evaluation method for the pressure vessel with internal wall-thinning defect, which is based on ASME design criteria. Pressure vessel has wall-thinning partially and patch reinforcement has been attached for reliable operating. However, present partial wall thinning could be through wall thinning at the next inspection time with present corrosion progress speed. Therefore safety margin was calculated for various conditions from present wall-thinning condition to additive patch reinforced condition via two-dimensional and three-dimensional, geometrically linear FE analyses using elastic materials.

Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system (시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.39 no.4
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

Limited internal fixation for the treatment of the Ovadia and Beals type II or III Pilon fracture (Ovadia와 Beals 제2형 또는 3형 경골 천정 골절의 제한적 내고정술을 이용한 치료)

  • Kim, Hyoung-Chun;Kim, Kwang-Yul;Lim, Mun-Sup;Kim, Jin-Hyoung;Kwon, Joon-Hyoung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.250-257
    • /
    • 2003
  • Purpose: Pilon fracture is caused by high energy and axial compression forces, and it is often associated with severe comminution and soft tissue injury. Recently, limited internal fixation of this fracture may avoid the soft tissue complications associated with formal open reduction and internal fixation and avoid incongruity of joint margin associated with conservative treatment. We have treated Ovadia and Beals type II or III pilon fracture with limited internal fixation and the results were satisfactory. Materials and Methods: We analyzed 15 cases of Ovadia and Beals type II or III fractures who were treated by limited internal fixation(K-wire or screw fixation) from January 1995 to December 2000. The average follow up period was 20 months(range, 12 to 38 months). According to the Ovadia and Beals classification, seven cases were type II, and eight cases were type III. Radiographic results were assessed by Ovadia and Beals criteria. We also assessed the functional results by Mast and Teipner criteria. Results: Radiographic results showed good in 67% and fair in 33% of cases. Clinical results showed good in 73% and fair in 27% of cases. There were no complications such as wound infection and skin necrosis, but traumatic arthritis were 2 cases. Conclusion: Pilon fractures are high energy injuries with significantly associated soft tissue damage and traumatic arthritis. Limited internal fixation offers good solution to Ovadia and Beals type II or III fracture.

  • PDF