• Title/Summary/Keyword: Internal loss

검색결과 1,362건 처리시간 0.028초

Impact of hydrogen on rupture behaviour of Zircaloy-4 nuclear fuel cladding during loss-of-coolant accident: a novel observation of failure at multiple locations

  • Suman, Siddharth
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.474-483
    • /
    • 2021
  • To establish the exclusive role of hydrogen on burst behaviour of Zircaloy-4 during loss-of-coolant accident transients, an extensive single-rod burst tests were conducted on both unirradiated as-received and hydrogenated Zircaloy-4 cladding tubes at different heating rates and internal overpressures. The visual observations of cladding tubes during bursting as well as post-burst are presented in detail to understand the effect of hydrogen concentration, heating rate, and internal pressure. Impact of hydrogen on burst parameters-burst stress, burst strain, burst temperature-during loss-of-coolant accident transients are compared and discussed. Rupture at multiple locations for hydrogenated cladding at lower internal pressure and higher heating rate is reported for the very first time. A novel burst criterion accounting hydrogen concentration in nuclear fuel cladding is proposed.

전기차와 내연기관차의 파워트레인 손실 및 효율 비교 (Comparative Study of Powertrain Loss and Efficiency for the Electric Vehicle and Internal Combustion Engine Vehicle)

  • 김정민
    • 한국기계가공학회지
    • /
    • 제18권7호
    • /
    • pp.29-35
    • /
    • 2019
  • In this paper, the component loss models of the electric vehicle(EV) and the internal combustion engine vehicle(ICEV) are developed to analyze the losses and efficiencies of these two types of vehicles. The EV powertrain efficiency decreases as the vehicle velocity increases over most of the vehicle velocity range because the battery efficiency decreases. Especially, the EV powertrain efficiency decreases significantly when the battery SOC is low. But the ICEV powertrain efficiency increases as the vehicle velocity increases. This is because the efficiencies of both the transmission and engine increases.

Streptococcus suis causes bacterial meningitis with hearing loss in patients without direct exposure to pigs in a regional pork industry territory

  • Joong-Goo Kim;Gil Myeong Seong;Young Ree Kim;Sang Taek Heo;Jeong Rae Yoo
    • Journal of Medicine and Life Science
    • /
    • 제20권1호
    • /
    • pp.43-47
    • /
    • 2023
  • Streptococcus suis (S. suis) is an emerging zoonotic pathogen that causes bacterial meningitis in humans. S. suis is an encapsulated gram-positive facultative anaerobic bacterium and is an important pathogen in pigs. This infectious disease usually manifests in humans as meningitis, endocarditis, septicemia, and arthritis. Most cases originate in Southeast Asia, and human S. suis infections are often reported in countries with a high density of pigs. Meningitis is a common clinical manifestation of S. suis infection. Moreover, hearing loss is a common complication that can be bilateral, profound, and/or permanent. This report presents two cases of bacterial meningitis and hearing loss caused by S. suis in patients without a history of direct exposure to pigs in an intensive pork industry region.

Ge를 첨가한 Nb$_3$Sn 초전도 선에서의 교류손실 및 미세조직 변화 (Influence of Ge addition on AC loss and micro-structure in $Nb_{3}Sn$ wires)

  • 하도우;이남진;오상수;하홍수;송규정;권영길;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2001
  • In order to investigate the effect of Ge addition to the Cu matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt % Ge alloys were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$. The values of AC loss of Ge added wires were decreased to 40 % compare with no addition wire. Low AC loss was due to segregation of Ge rich layer in the Cu-Ge matrix. If Ge added wire with thin Nb filaments were fabricated, slow diffusion rate of Sn would be overcome and decreased AC loss that is weak Point of internal tin method.

  • PDF

Impact of monthly arteriovenous fistula flow surveillance on hemodialysis access thrombosis and loss

  • Ara Ko;Miyeon Kim;Hwa Young Lee;Hyunwoo Kim
    • Journal of Medicine and Life Science
    • /
    • 제20권3호
    • /
    • pp.115-125
    • /
    • 2023
  • Arteriovenous fistula flow dysfunction is the leading cause of vascular access thrombosis and loss in patients undergoing hemodialysis. However, data regarding the influence of access flow rate measurements on the long-term outcomes of access are limited. This study aims to identify accesses at a high risk of thrombosis and loss among patients undergoing hemodialysis by measuring the access flow rate and exploring an optimal threshold value for predicting future access thrombosis. We enrolled 220 patients with arteriovenous fistula undergoing hemodialysis. The primary outcome was the occurrence of access thrombosis. Access flow rates were measured monthly using the ultrasound dilution method and were averaged using all measurements from patients with patent access. In patients experienced access thrombosis, those immediately before the thrombosis were selected. Using these data, we calculated the access flow rate threshold for thrombosis occurrence by analyzing the receiver operating characteristic curve, and the patients were divided into two groups according to whether access flow rates were higher or lower than 400 mL/min. During a median follow-up period of 3.1 years, 4,510 access flows were measured (median measurements per patient, 33 times; interquartile range, 11-54). A total of 65 access thromboses and 19 abandonments were observed. Access thrombosis and loss were higher in the lowflow group than in the high-flow group. This study revealed that low access flow rates are strongly associated with access thrombosis occurrence and subsequent loss of arteriovenous fistulas in patients undergoing hemodialysis.

마황복용이 성인의 체중감소에 미치는 영향에 대한 이중맹검 임상연구 (Effects of Mahuang for Weight Loss in Healthy Adults : A Double-Blind, Controlled, Randomized, Clinical Trial)

  • 여진주;형례창;양창섭;정승일;서의석;장인수
    • 대한한의학회지
    • /
    • 제28권1호통권69호
    • /
    • pp.63-71
    • /
    • 2007
  • Objectives : To provide an objective assessment of the effectiveness for weight loss of Mahuang. Methods : Effects were assessed by measuring changes in body weight, body mass index (BMI), body fat (kg, %),body muscle, and abdominal f3t ratio. The subjects of this study were healthy adults who agreed to participate in this study. Eligibility requirements include age between 20 and 50 and BMI more than 18.5 kg/m2. One hundred subjects were randomly assigned to two groups (control and Mahuang group) in a double-blind manner. Mahuang group subjects took 8g of Mahuang capsule/day for two weeks; control subjects took the same amount of indistinguishable placebo. We analyzed the body weight, body mass index, body fat, abdominal fat, body muscle and BMR (basal metabolic rate) before and after the study. Result After two weeks of clinical trial, body weight and BMI decreased in both groups, but the Mahuang group showed more significant decrease. On body fat, the Mahuang group showed significant decrease. while it increased in the placebo group. Although body muscle, body fat ratio and basic metabolic rate showed differences between the two groups, there was no statistical significance. Conclusion : It is suggested that intake of Mahuang may induce weight loss and body f3f decrease in healthy adults.

  • PDF

초소형 고체 추진제 추력기의 내탄도 성능연구 (Internal Ballistic Analysis of Solid Propellant Micro-Thruster)

  • 양준서;이종광;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.215-218
    • /
    • 2007
  • 고체추진제를 사용한 초소형 추력기의 내탄도 모델링과 성능예측에 관하여 기술하였으며, 특히 초소형화 되면서 고려해야하는 연소실 내의 열손실을 고려하였다. 추진제는 일반 HTPB-AP계열을 선택하였으며, 계산 모델은 간단한 1차원 축대칭 end-burner 모델로 정하였다. 연소실내의 화염에 노출되는 표면과 체적에 대한 비율을 변화시키면서 연소실 가스 온도, 압력, 추력을 계산하여 본 논문의 경우 열손실효과로 약 3%의 총역적 감소가 있음을 확인하였다.

  • PDF

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

전력 케이블용 저밀도 폴리에틸렌의 냉각 조건에 따른 기계적 및 유전손실에 관한 연구 (A study on the Dynamic Mechanical and Dielectric Loss according to Quenched Condition in Low Density Polyethylene fer Power Cable)

  • 김재환;권병휘;박재준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.27-37
    • /
    • 1992
  • We studied the dielectric and dynamic mechanical losses according to the quenching condition in low density polyethylene being used to power cables. According to severe quenching condition, characteristics of the temperature in internal friction los peak have decreased the magnitude of loss peak as amorphous region lengthen. From now on, the frequency dependent characteristics of dielectric loss have investigated at room temperature, and the dielectric loss peak due to interface polarization, between crystal and amorphous region, occurs about 30[Hz], and that, the peak due to orientation polarization in correspondence to the loss peak in internal friction has observed at about 3 [MHz]. As quenching velocity increased, the effect on quenching condition about the dielectric loss has decreased the magnitude of the loss peak. Thus, estimation has been carried out on the activation energies nd the degree of crystallinity by means of X-ray diffraction are obtained as follows: room quenching : 26.4 [kal/mole] and 54.73 [%], ice quenching : 25.6 [kcal/mole] and 48.47 [%], liquid nitrogen quenching specimens : 22.56 [kcal/mole] and 40.95 [%].

  • PDF

WBG 스위치를 적용한 소용량 플라이백 컨버터의 내부손실 특성과 효율 개선에 관한 연구 (A Study A on Internal Loss Characteristics and Efficiency Improvement of Low Power Flyback Converter Using WBG Switch)

  • 안태영;유정상
    • 반도체디스플레이기술학회지
    • /
    • 제19권4호
    • /
    • pp.99-104
    • /
    • 2020
  • In this paper, efficiency and loss characteristics of GaN FET were reported by applying it into the QR flyback converter. In particular, for the comparison of efficiency characteristics, QR flyback converter experimental circuits with Si FET and with GaN FET were separately produced in 12W class. As a result of the experiment, the experimental circuit of the QR flyback converter using GaN FET reached a high efficiency of 90% or more when the load power was 2W or more, and the maximum efficiency was observed to be about 92%, and the maximum loss power was about 1.1W. Meanwhile, the efficiency of the experimental circuit with Si FET increased as the input voltage increased, and the maximum efficiency was observed to be about 82% when the load power was 9W or higher, and the maximum loss power was about 2.8W. From the results, it is estimated that that in the case of the experimental circuit applying the GaN FET switch, the power conversion efficiency was improved as the switching loss and conduction loss due to on-resistance were reduced, and the internal loss due to the synchronous rectifier was minimized. Consequently, it is concluded that the GaN FET is suitable for under 20W class power supply unit as a high efficiency power switch.