• Title/Summary/Keyword: Internal gap

Search Result 407, Processing Time 0.02 seconds

Is an Arthroscopically Assisted Reduction and Fixation Necessary in the Medial Malleolar Fracture of the Ankle? (족관절 내과 골절시 보조적 관절경적 정복 및 내고정술이 필요한가?)

  • Shin, Dong Min;Ju, Pyong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.93-96
    • /
    • 1998
  • We treated 10 cases of the medial malleolar fracture of the ankle by open reduction and internal fixation from June 1997 to December 1997. After the rigid internal fixation, we measured the gap of the fracture site and the step off of the articular surface by special instrument under the ankle arthroscopy whether it was reduced anatomically or not. And we tried to know the necessity of the arthroscopically assisted reduction and fixation in the medial malleolar fracture of the ankle. Under the arthroscopic view, all 10 cases were anatomically reduced as less than 1 mm of gap of the fracture site and less than 1mm of step off of the articular surface after open reduction and internal fixation in the medial malleolar fractures. In conclusion, through the arthroscopic management, it has advantage in finding and treating the accompanying intraarticular lesion, but also has disadvantage in setting the arthroscope and prolonging the operation time.

  • PDF

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Trial Manufacture and Characteristics of a Multi-discharge Type ozonizer(I) (다중방전형 오존발생기의 試作 및 特性(I))

  • Song, Hyeon-Jik;Lee, Gwang-Sik;Park, Won-Ju;Lee, Dong-Heon;Kim, Geum-Yeong;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.533-541
    • /
    • 1999
  • Multi-discharge type ozonizer(MDO) using superposed silent discharge has been designed and manufactured. It consists of three electrodes( central electrode, internal electrode, and external electrode ) and double gaps( gap between central electrode and internal electrode, gap between internal electrode and external electrode ). Therefore, ozone is generated by superposing silent discharges generated between the gaps respectively. And the MDO consists of three types of superposed discharge ozonizers according to voltage appling method for each electrode ; A.C. high voltages are applied two of three electrodes with phase difference of 180[˚], the other electrode is a ground. This paper describes that discharge and ozone generation characteristics of MDO which comprising central electrode and internal electrode applied A.C. high voltages with phase difference of 180[˚] respectively, and the grounded external electrode. As a result, the maximum ozone concentration, generation, and yield can be obtained 10208[ppm], 6.4[g/h], and 280[g/kwh] respectively.

  • PDF

Computational Study of Magnetically Suspended Centrifugal Blood Pump (The First Report: Main Flow and Gap Flow)

  • Ogami, Yoshifumi;Matsuoka, Daisuke;Horie, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.2
    • /
    • pp.102-112
    • /
    • 2010
  • Artificial heart pumps have attracted the attention of researchers around the world as an alternative to the organ used in cardiac transplantation. Conventional centrifugal pumps are no longer considered suitable for long-term application because of the possibility of occurrence of blood leakage and thrombus formation around the shaft seal. To overcome this problem posed by the shaft seal in conventional centrifugal pumps, the magnetically suspended centrifugal pump has been developed; this is a sealless rotor pump, which can provide contact-free rotation of the impeller without leading to material wear. In Europe, clinical trials of this pump have been successfully performed, and these pumps are commercially available. One of the aims of our study is to numerically examine the internal flow and the effect of leakage flow through the gap between the impeller and the pump casing on the performance of the pump. The results show that the pressure head increases compared with the pump without a gap for all flow rates because of the leakage of the fluid through the gap. It was observed that the leakage flow rate in the pump is sufficiently large; further, no stagnant fluid or dead flow regions were observed in the pump. Therefore, the present pump can efficiently enhance the washout effect.

Characteristics of Diamondike Carbon thin Films by Low Discharging Frequency(450KHz) PECVD (저주파수(450 KHz) PECVD에 의한 Diamondlike Carbon박막의 특성)

  • Kim, Han-Ju;Ju, Seung-Gi
    • Korean Journal of Materials Research
    • /
    • v.4 no.2
    • /
    • pp.227-232
    • /
    • 1994
  • Diamondlike carbon thin film has been fabricated with low discharging frequency, 450KHz by plasma enhanced chemical vapor deposition. Its physical properties such as optical band gap, microhardness and internal stress have been compared with 13.56MHz film. Optical band gap of 450KHz DLC thin film was less than 13.56MHz film and it was found that C-H bond concentration and total hydrogen contents in the film decreased greatly as the result of FT-IR and CHN analysis. Also, when DLC thin film was fabricated with low discharging frequency, it was expected that the adhesion of the film to the substrate was improved by the great decrease of internal stress without any considerable decrease of microhardness.

  • PDF

An Internal Segmentation Method for the On-line Recognition of Run-on Characters (온라인 연속 필기 한글의 인식을 위한 내부 문자 분할에 관한 연구)

  • 정진영;전병환;김우성;김재희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.1231-1238
    • /
    • 1995
  • In on-line character recognition, to segment input character is important. This paper proposes an internal character segmentation algorithm. The internal segmentation algorithm produces candidate words by considering possible combinations of Korean alphabets. In this process, we make use of projections of strokes onto the horizontal axis to remove ambiguities among candidate words. As a result of experiments, the internal segmentation algorithm shows better performance than external segmentation algorithm as the gap between sample characters becomes smaller.

  • PDF

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.

Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

  • Habib, Syed Rashid;Asiri, Waleed;Hefne, Mohammed Jameel
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.444-450
    • /
    • 2014
  • PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ${\times}200$ magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be $155.93{\pm}33.98{\mu}m$ with Anatomical Occlusal preparation design having the least gap value of $139.23{\pm}30.85{\mu}m$ showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.

The Characteristics of Ozone Generation Synergy Effect for 3 Electrode-1 Discharge Gap Silent Discharge Type Ozonizer using Frequency-Vacuum (주파수-진공도를 이용한 3전극-1방전간극 무성방전형 오존발생기의 오존생성 상승 효과 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-101
    • /
    • 2005
  • The silent discharge type ozonizer with three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode) has been designed and manufactured. It is a silent discharge type ozonizer for which the AC high frequency voltages applied to the central electrode within vacuum discharge tube and the internal electrode for which the external electrode is a ground Ozone is generated by silent discharge in discharge gap. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, frequency of AC power source, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, ozone characteristics proportional to vacuum of discharge tube and frequency of AC power source. The maximum value of ozone can be obtained 7,700[ppm], 460[mg/h] and 70[g/kwh].

Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro (Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro)

  • Lee, Tae-Hee;Lee, Ha-Bin;Kim, Ji-hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.