• Title/Summary/Keyword: Internal exposure

Search Result 623, Processing Time 0.032 seconds

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

  • Spencer C. Lacy;Mina M. Benjamin;Mohammed Osman;Mushabbar A. Syed;Menhel Kinno
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.108-115
    • /
    • 2023
  • BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

Utilization of Immersion-Drying Method for Measuring Damage Depth of Fire-Damaged High-Strength Concrete (화재로 손상된 고강도 콘크리트의 손상 깊이 측정을 위한 수중침지 건조방법의 활용)

  • Kim, Jong;Lim Gun-Su;Beak, Seung-Bok;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.297-308
    • /
    • 2024
  • This study presents a novel approach for evaluating fire-induced damage depth in concrete. The methodology leverages the principle that exposure to high temperatures causes internal expansion within concrete, leading to increased voids and microcracks in the damaged zones. This heightened porosity results in greater absorption rates compared to undamaged areas. By immersing fire-damaged concrete samples in water and subsequently monitoring the drying process, the depth of damage can be assessed. Differences in drying rates and color variations between damaged and undamaged areas serve as visual indicators for determining the extent of the damage. Experimental results from this water immersion method revealed damage depths of 38.7mm and 37.5mm for two different concrete mixtures. These measurements notably surpass the damage depths estimated using traditional phenolphthalein-based methods. This discrepancy suggests that utilizing the absorption rate principle, which is directly linked to the physical changes caused by thermal expansion, offers a more accurate and sensitive assessment of fire damage depth compared to methods relying solely on the presence of Portlandite for colorimetric indication.

Evaluation of Electrical Damage to Electric-vehicle Bearings under Actual Operating Conditions (실제 운전조건을 고려한 전기자동차 베어링의 전기적 손상 평가 )

  • Jungsoo Park;Jeongsik Kim;Seungpyo Lee
    • Tribology and Lubricants
    • /
    • v.40 no.4
    • /
    • pp.111-117
    • /
    • 2024
  • Due to global CO2 emission reductions and fuel efficiency regulations, the trend toward transitioning from internal combustion engine vehicles to electric vehicles (EVs) has accelerated. Consequently, the problem of EV failures has become a focal point of active research. The parasitic capacitance generated during motor-shaft rotation induces voltage that deteriorates the raceway and ball surfaces of bearings, causing electrical damage in EVs. Despite numerous attempts to address this issue, most studies have been conducted under high viscosity lubricant and low load conditions. However, due to factors such as high-speed operation, rapid acceleration and deceleration, motor heating, and motor system-decelerator integration, current EV applications have shown diminished stability in lubrication films of motor bearings, thereby leveraging the investigation to address the risk of electrical damage. This study investigates the electrical damage to rolling bearing elements in EV motor drive systems. The experimental analysis focuses on the effects of electric currents and operational loads on bearing integrity. A test rig is designed to generate high-rate voltage specific to a motor system's parasitic capacitance, and bearing samples are exposed to these currents for specified durations. Component evaluation involves visual inspections and vibration measurements. In addition, a predictive model for electrical failure is developed based on accumulated data, which demonstrates the ability to predict the likelihood of electrical failure relative to the duration and intensity of current exposure. This in turn reduces uncertainties in practical applications regarding electrical erosion modes.

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Experimental Studies on the Effects of Chunggeumtang (청금탕(淸金湯)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Eung-Sik;Lee, Si-Hyeong
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.1-26
    • /
    • 1997
  • Chunggeumtang has been used in Korea for many centuries as a treatment for respiratory disease. The effect of Chunggeumtang on tracheal smooth muscle is not konwn. The purpose of the present study is to determine the effect of Chunggeumtang on histamine and acetylcholine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig(500g, male) and Sprague Dawley rats (250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each rat and guinea pig was cut into equal swegments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force diplacement transducers under 0.5g loading tension. The dose of histamine (His) and acetylcholine (Ach) which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine and acetylcholine($10^{-7}{\sim}10^{-4}M$). Contractions evoked by His ($ED_{50}$) and Ach ($ED_{50}$) were inhibited significantly by Chunggeumtang. In guinea pig tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.1%after\;30{\mu}l/ml$ Chunggeumtang, and 49.4% (p<0.01) after $100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.7%\;after\;30{\mu}l/ml$ Chunggeumtang, and $54.2%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Also, in guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $30.6%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $53.0%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $24.1%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $55.3%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Propranolol and indomethacin($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Chunggeumtang. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 27.6% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.2% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by histamine contraction. Indomethacin, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 20.0% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 16.9% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.4% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 23.1% (p<0.05) in rat induced by histamine contraction. Methylene blue($10^{-7}M$) did not significantly alter the inhibitory effect of Chunggeumtang. Also, I could find the effects of Chunggeumtang and Chunggeumtanggamorphine on the tracheal smooth muscle in guinea pig and rat did not change significantly. These results indicate that Chunggeumtang can relax histamine and acetylcholine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves sympathetic effects and the release of cyclooxygenase products.

  • PDF

Biological Monitoring of Paint Handling Workers exposed to PAHs using Urinary 1-Hydroxypyrene (다핵방향족탄화수소류에 노출된 페인트 취급 근로자에서 요 중 1- Hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong-Seong;Kim, Eun-A;Lee, Yong-Hag;Moon, Deog-Hwan;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Cytosolic Phospholipase A2 Activity in Neutrophilic Oxidative Stress of Platelet-activating Factor-induced Acute Lung Injury (Platelet-activating Factor에 의한 급성폐손상에서 호중구성 산화성 스트레스에 관여하는 Cytosolic Phospholipase A2 활성도의 변화)

  • Kwon, Young Shik;Hyun, Dae Sung;Lee, Young Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.497-506
    • /
    • 2007
  • Background: The present investigation was performed in rats and isolated human neutrophils in order to confirm the presumptive role of the positive feedback loop of cytosolic phospholipase $A_2$ ($cPLA_2$) activation by plateletactivating factor (PAF). Methods: The possible formation of the positive feedback loop of the $cPLA_2$ activation and neutrophilic respiratory burst was investigated in vivo and in vitro by measurement of the parameters denoting acute lung injury. In addition, morphological examinations and electron microscopic cytochemistry were performed for the detection of free radicals in the lung. Results: Five hours after intratracheal instillation of PAF ($5{\mu}g/rat$), the lung leak index, lung myeloperoxidase (MPO) activity, the number of neutrophils and the concentration of cytokine-induced neutrophil chemoattractant (CINC) in bronchoalveolar lavage fluid were increased by PAF as compared with those of control rats. The NBT assay and cytochrome-c reduction assay revealed an increased neutrophilic respiratory burst in isolated human neutrophils following exposure to PAF. Lung and neutrophilic $cPLA_2$ activity were increased following PAF exposure and exposure to hydrogen peroxide increased $cPLA_2$ activity in the lung. Histologically, inflammatory findings of the lung were observed after PAF treatment. Remarkably, as determined by $CeCl_3$ cytochemical electron microscopy, increased production of hydrogen peroxide was identified in the lung after PAF treatment. Conclusion: PAF mediates acute oxidative lung injury by the activation of $cPLA_2$, which may provoke the generation of free radicals in neutrophils.

A Study on Urinary Cadmium Concentration and Renal Indices of Inhabitant in an Abandoned Mine Area (폐광지성(廢鑛地城) 주민(住民)의 요중(尿中) 카드뮴 농도(濃度)와 현기능평가(賢機能評價))

  • Park, Jung-Duck;Park, Chan-Byung;Choi, Byung-Sun;Kang, Eun-Yong;Hong, Yeon-Pyo;Chang, Im-Won;Chun, Byung-Yeol;Yeh, Min-Hae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.424-439
    • /
    • 1998
  • Urinary cadmium is used as a sensitive indicator for internal Cd dose, and increased excretion of $N-acetyl-\beta-D-glucosaminidase(NAG)$, $\beta_2-microglobulin(MG)$ and total protein are useful indices for renal dysfunction by chronic exposure to Cd. The target group was 184 inhabitant(82 men and 102 women) in an abandoned mine area known as exposure to low level Cd. The control group was took 160 individuals(64 men and 96 women) in Cd not-exposed area. Urinary Cd concentration was significantly higher in the target group than the control. The geometric mean of urinary Cd for male was $2.56{\mu}g/\ell,\;2.80{\mu}g/g$ creatinine and $2.50{\mu}g/S.G.$ in the target group and $1.19{\mu}g/\ell,\;1.36{\mu}g/g$ creatinine and $1.17{\mu}g/S.G.$ in the control. For female $2.69{\mu}g/\ell,\;3.94{\mu}g/g$ creatinine and $2.63{\mu}g/S.G.$ in the target group and $1.27{\mu}g/\ell,\;1.97{\mu}g/g$ creatinine and $1.25{\mu}g/S.G.$ in the control, respectively. In addition, urinary Cd of the target group had affected by the period of residence and dietary habit for the rice and the vegetables from the target area. These findings suggest the chronic exposure to Cd of the target population. Mean excretion of urinary NAG, $\beta_2-MG$ and total protein were not significant between two groups. In the target group, urinary NAG activity and total protein were significantly correlated with urinary Cd, but $\beta_2-MG$ was not related. Urinary excretion of NAG, $\beta_2-MG$ and total protein were significantly increased in $10\leqq$ than in <2 of urinary Cd level. In $2\sim10$ group of urinary Cd level, the excretion of NAG significantly increased while not showed for $\beta_2-MG$. In present study, urinary excretion of NAG was relatively sensitive than $\beta_2-MG$ in chronic exposure population to low level Cd.

  • PDF