• Title/Summary/Keyword: Internal environment

Search Result 2,384, Processing Time 0.033 seconds

A Basic Study on the Performance Relationship among Internal Marketing Factors in Construction Company by Using AHP Method (AHP기법을 활용한 건설기업 내부마케팅 구성요인 간의 성과관계 기초연구)

  • Lee, Jong Sun;Kim, Boo-Young;Cho, Han Byung;Son, Kiyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.224-225
    • /
    • 2014
  • In recent years, the domestic construction business is continuously stagnated caused by housing depression, global financial crisis etc. To overcome these difficulties, the construction companies should reinforce the internal marketing like the service business. However, it is not easy to conduct active internal marketing reinforcement since the companies do not directly receive customers under special situation like construction. Therefore, it is necessary to resolve the urgent issue by selecting order of priority among internal marketing factors. To address this issue, the objective of this study is to analysis the internal marking factors by using Analytic Hierarchy Process.

  • PDF

Research Trend on Internal Marketing of Medical Service Organization

  • Kim, Woon-Shin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.83-88
    • /
    • 2016
  • In this research aimed to deduce internal marketing factors, purpose, and their practical application by analyzing preceding researches on internal marketing of Korean medical service organization and investigating the recent trend of its research. Subjects of research are ten preceding researches that have been published in KCI records for the last five years from 2011 to 2016. Summarize result of researches, first, internal factors that were most frequently used were internal communication, compensation system, and education and training, which were used by 8(.8). Second, occupations that had most interest in the internal marketing research appeared to be nursing(.9) and administration(.3). Third, the practical application of the internal marketing appeared to be job satisfaction(.8), followed by customer orientation(.6), and organizational commitment(.4). Suggestion do, necessary to develop subordinate factors regarding the realistic internal marketing, such as both-sided internal communication enhancement, education and training, compensation system differentiated by individuals and teams, fairness in performance rating, work environment improvement, delegation of authority, career development, shared organizational vision in order to maximize job satisfaction, job commitment, and organizational commitment of employees as internal customers, before establishing strategies to satisfy patients and guardians who are external customers.

Occupational Lung Cancer Surveillance in South Korea, 2006-2009

  • Leem, Jong-Han;Kim, Hwan-Cheol;Ryu, Jeong-Seon;Won, Jong-Uk;Moon, Jai-Dong;Kim, Young-Chul;Koh, Sang-Baek;Yong, Suk-Joong;Kim, Soo-Geun;Park, Jae-Yong;Kim, In-Ah;Kim, Jung-Il;Kim, Jung-Won;Lee, Eui-Cheol;Kim, Hyoung-Ryoul;Kim, Dae-Hwan;Kang, Dong-Mug;Hong, Yun-Chul
    • Safety and Health at Work
    • /
    • v.1 no.2
    • /
    • pp.134-139
    • /
    • 2010
  • Objectives: The lung cancer mortality in Korea has increased remarkably during the last 20 years, and has been the first leading cause of cancer-related deaths since 2000. The aim of the current study was to examine the time trends of occupational lung cancer and carcinogens exposure during the period 2006-2009 in South Korea, by assessing the proportion of occupational burden. Methods: We defined occupational lung cancer for surveillance, and developed a reporting protocol and reporting website for the surveillance of occupational lung cancer. The study patients were chosen from 9 participating university hospitals in the following 7 areas: Seoul, Incheon, Wonju, Daejeon, Daegu, Busan, and Gwangju. Results: The combined proportion of definite and probable occupational lung cancer among all lung cancers investigated in this study was 10.0%, 8.6%, 10.7%, and 15.8% in the years 2006 to 2009, respectively, with an average of 11.7% over the four-year study period. The main carcinogens were asbestos, crystalline silica, radon, polyaromatic hydrocarbons (PAHs), diesel exhaust particles, chromium, and nickel. Conclusion: We estimated that about 11.7% of the incident lung cancer was preventable. This reveals the potential to considerably reduce lung cancer by intervention in occupational fields.

Cyber Security Management of Small and Medium-sized Enterprises with Consideration of Business Management Environment (중소기업의 기업경영 환경을 고려한 사이버 보안 관리)

  • Chun, Yong-Tae
    • Korean Security Journal
    • /
    • no.59
    • /
    • pp.9-35
    • /
    • 2019
  • Until now, a lot of research on cyber security have been tried, but there have been few studies on overall relationships, including internal factors and external factors. Therefore, this study examined cyber security management considering not only internal elements of SMEs but also corporate management environment. The first qualitative analysis and the second quantitative analysis were conducted through mixed method research. Qualitative analysis was conducted through a semi-structured interview method, and three themes were found: insufficient cyber security management system, internal noncooperation for cyber security, and problems derived from decision-making system. In the quantitative analysis, multiple regression analysis was conducted on the data obtained through the questionnaire. The perception of cyber threats and internal support among independent variables positively influenced the cyber security management system or the dependent variable. Through this study, internal variables had a causal impact on the cyber security management system rather than external environment variables. This implies that the variables related to the organizational culture such as employees' perception are important. These results are expected to provide practical significance for enhancing the cyber security management system in SMEs.

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis (CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구)

  • Lee, Sung-Hyoun;Yu, Byeong-Kee;Lee, Chan-Jung;Lim, Yeong-Taek
    • Journal of Mushroom
    • /
    • v.15 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • The oyster mushroom cultivation house typically has multiple layers of growing shelves that cause the disturbance of air circulation inside the mushroom house. Due to this instability in the internal environment, growth distinction occurs according to the area of the growing shelves. It is known that minimal air circulation around the mushroom cap facilitates the metabolism of mushrooms and improves their quality. For the purpose of this study, a CFD analysis FLUENT R16 has been carried out to improve the internal environment uniformity of the oyster mushroom cultivation house. It is found that installing a section of the working passage towards the ceiling is to maintain the internal environment uniformity of the oyster mushroom cultivation house. When all the environment control equipment - including a unit cooler, an inlet fan, an outlet fan, an air circulation fan, and a humidifier - were operated simultaneously, the reported Root Mean Square (RMS) valuation the growing shelves were as follows: velocity 23.86%, temperature 6.08%, and humidity 2.72%. However, when only a unit cooler and an air circulation fan operated, improved RMS values on the growing shelves were reported as follows: velocity 23.54%, temperature 0.51%, and humidity 0.41%. Therefore, in order to maintain the internal environment uniformity of the mushroom cultivation house, it is essential to reduce the overall operating time of the inlet fan, outlet fan, and humidifier, while simultaneously appropriately manage the internal environment by using a unit cooler and an air circulation fan.

Comparisons of Models for Thermal Internal Boundary Layer Hight Based on Measurements of the Water Tank Experiment

  • Koo, Youn-Seo;Yoon, Hee-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E2
    • /
    • pp.97-103
    • /
    • 2000
  • A Thermal Internal Boundary Layer(TIBL) develops over the landside from the coast due to the surface temperature difference between the land the sea when sea breeze froms. The TIBL plays an important role in determining the pollutant concentrations where the plume emitted from a tall stack near the coast fumigates to the ground. The fumigation results in the high ground the TIBL height from the available meterological data is very important. The TIBL models avaliable in the literature were analyzed to identify the suitable model to apply in the fumigation. The TIBL heights predicted by the existing models were compared with the measurements in the water tank experiment. The results show that the TIBL models by Raynor is appropriate to predict the height of TIBL.

  • PDF

금강 부여 군수리 충적 대수층 조사를 위한 고해상도 지구물리탐사 - 탄성파 탐사 및 GPR 조사를 중심으로 -

  • 김형수;서만철;이철우;진세화
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.287-291
    • /
    • 2003
  • To delineate the internal structures of alluvial aquifer, high resolution seismic and GPR methods were adopted in Buyeo Gunsu-Ri area. The result of seismic refraction survey shows the water table of the aquifer and the result of seismic reflection reveals the basement and somewhat dominant internal structures of alluvial aquifer. The internal heterogeneity due to variations in channel behavior can be delineated using GPR survey. GPR profiles for the point bar deposits near Buyeo county reveals two different stratigraphic units the lower inclined heterogeneous strata and the upper horizontally stratified strata. According to the increase of demand for water resource using artificial recharge in alluvium, it is believed that the information acquired by high resolution geophysical methods will have an important roles for the effective and sustainable development and usage of groundwater in alluvial aquifer.

  • PDF

Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss (압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가)

  • Park You-me;Kim Rack-woo;Kim Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.