• 제목/요약/키워드: Internal discharge

검색결과 652건 처리시간 0.031초

액체 점도에 따른 Y-jet 노즐 내부 유동 및 분무 특성의 변화 (Effect of liquid viscosity on internal flow and spray characteristics of Y-jet atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.4053-4061
    • /
    • 1996
  • Internal flow characteristics within Y-jet atomizers and the local drop size distribution and cross-sectional averaged drop size at the outside were investigated with the liquid and air injection pressures, mixing port length of atomizers, and the liquid properties taken as parameters. To examine the effect of the liquid viscosity, glycerin-water mixtures were used in this study. The liquid viscosity plays only a minor role in determining the internal flow pattern and the spatial distribution shape of drops, but the drop sizes themselves generally increase with increasing of the liquid viscosity. An empirical correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results; the liquid discharge coefficient strongly depends on the liquid flow area at the mixing point which is proportional to the local volumetric quality(.betha.$_{Y}$), and the volumetric quality was included in the correlation. Regardless of the value of the liquid viscosity, the compressible flow through the gas port was well represented by the polytropic expansion process(k=1.2), and the mixing point pressure could be simply correlated to the aspect ratio( $l_{m}$/ $d_{m}$) of the mixing port and the air/liquid mass flow rate ratio( $W_{g}$/ $W_{f}$) as reported in the previous study.udy.udy.y.

3상 전압인가형 중첩방전 오존발생기의 오존생성 상승효과 (Ozone Generation Synergy Effects of Three-Phase Voltage Apply Type Superposed Discharge Ozonizer)

  • 이병준;이상근;송현직;김영훈;박원주;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.468-476
    • /
    • 2000
  • Nowadays, ozone is mainly utilized for water treatment and home equipments. Although the demand for ozone is increasing, the ozone yield of silent discharge type ozonizer is low. Therefore, it is expected to improve the energy efficiency and ozone yield of an ozonizer. In this paper, a new ozone generation system is proposed. The 60[Hz] three-phase voltage is applied to three-phase superposed discharge type ozonizer(3PSDO) which has three electrodes(central, internal and external electrodes). There is no discharge pause time when three-phase voltage is applied due to 120-degree phase difference of applied voltage. The synergy effect of the three-phase superposed discharge type ozonizer is investigated by comparing with the three sort of single-phase discharge type ozonizer(1PDO). So, three-phase superposed discharge type ozonizer is able to obtain high ozone yield, and optimize discharge space, because this can increase the discharge power at low applied voltage.

  • PDF

전류변화에 따른 Over Cut에 관한 실험적 연구

  • 신근하
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 추계학술대회 논문
    • /
    • pp.58-63
    • /
    • 1996
  • A study is drawn up its result's tables and graphs by measuring tools(outside micrometer cylinder gauge and dial caliper gauge) on the difference of diameter volumes from before-discharge and after-discharge under 52 Kind's experimental condition by cupper and graphite electrode of CNC EDM. The EDM is attached with A.V.R. and memory scope for keep up accuracy and the fixed table of work piece is used in order to eliminate the noise by the internal resistance of it and forcing to eradicate the discharge liquid. It is analyzed cutting conditions to compare its wave value and pulse time.(Ton Toff) through voltage and current for decreasing working error.

  • PDF

CAPACITY ANALYSIS OF THE SILVER OXIDE-ZINC CELL (PHASE 1)

  • 이완구
    • 기술사
    • /
    • 제14권4호
    • /
    • pp.15-25
    • /
    • 1981
  • Electrical behaviors of the divalent silver oxide-zinc cell were analyzed for imporving capacity and keeping electrodes from passivation or sharp increases of cell internal resistance in the course of discharge. One of primary factors in relation to lowering performance can be depicted by cell internal resistance increase being created by various routes, first by insufficiency and/or the carbonation of the electrolyte, secondly by barrier blockage, thirdly by electrode passivation which are due to improper material use of wrong processing, and by gassing as fourth cause. The carbonation causes electrobyte to have impedance up as well as poor amalgamation, resulting in vigorous corrosion reaction of copper plated inner top, evolving hydrogen gas. Electrical characteristics of the cell was reviewed to elucidate relationships between the discharge capacity and the cell internal resistance.

  • PDF

납 축전지 병렬운전시 발생하는 전류 불평형 현상분석 및 대책 (Unbalance load current of Operating in Parallel of Lead acid batteries connection condition)

  • 반한식;곽철훈;최규하;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.210-213
    • /
    • 1999
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the necessary voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. The circular-current, however, could be occurred when the system is driven in parallel. As a result, the new batteries are heated by over-change and discharge, and the over charge current makes to increase the rust of the positive grid and consequently the shortened life of the new batteris would be shown. In this paper, the internal resistance of charge and discharge will be balanced, through inserting the resistance into the system by way of calculation of the changed amount of internal resistance.

  • PDF

사판 식 축 피스톤 펌프 밸브블록의 구조개선에 관한 연구(2) (A Study on Structural Improvement of the Swashplate Axial Piston Pump Valve Block (2))

  • 김정화;신미정;김명규
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.76-81
    • /
    • 2018
  • This study aims to provide ways to achieve structural improvements of the internal flow path of the discharge plenum of a swash plate piston pump valve block vulnerable to cracks. This paper corresponds to Part II, which consists of a structural interpretation of the internal flow path of the discharge plenum of the valve block. The simple model result reviewed in Part I was incorporated into the valve block model and five different design changes were reviewed as part of the study on the structural improvement of the internal flow path of the valve block.

초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발 (A development of intelligent spacer built in the Internal type UHF partial discharge sensor)

  • 김동석;황철민;김영노;최재옥;서왕벽;한봉수;최수헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.163-164
    • /
    • 2007
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge ceil.

  • PDF

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

다중방전형 오존발생기의 방전 및 오존생성특성 (Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer)

  • 전병준;문경수;송현직;김긍영;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

중첩방전형 오존방생기의 특성(III) (Characteristics of a Superposed Discharge Type Ozonizer(III))

  • 송현직;이광식;이동인;김기채;이동헌;김금영;이춘하;전영주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF