• 제목/요약/키워드: Internal connection

검색결과 441건 처리시간 0.033초

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

임플란트와 상부구조물 사이의 micromotion에 관한 연구 (A study on the micromotion between the dental implant and superstructure)

  • 김지혜;송광엽;장태엽;박주미
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가 (EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

Effects of RHS face deformation on the rigidity of beam-column connection

  • Hadianfard, M.A.;Rahnema, H.
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.489-500
    • /
    • 2010
  • The rigid connections of I-beams to Rectangular Hollow Sections (RHS) in steel structures usually behave as semi-rigid connection. This behavior is directly related to the column face deformation. The deformation in the wall of RHS column in the connection zone causes a relative rotation between beam end and column axis, which consequently reduces the rigidity of beam-column connection. In the present paper, the percentages of connection rigidity reduction for serviceability conditions are evaluated by using the finite element analysis. Such percentages for RHS columns without internal stiffeners are considerable, and can be calculated from presented graphs.

Large Area Plasma Characteristics using Internal Linear ICP (Inductively Coupled Plasma) Source for the FPD processing

  • Kim, Kyong-Nam;Lim, Jong-Hyeuk;Yeom, Geun-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.544-547
    • /
    • 2006
  • In this study, the characteristics of large area internal linear ICP sources of $1,020mm{\times}920mm$ (substrate area is $880mm{\times}660mm$) were investigated using a multiple linear antennas with U-type parallel connection. Using the multiple linear antennas with U-type parallel connection, a high plasma density of $2{\times}10^{11}/cm^3$ and a high power transfer efficiency of about 88% could be obtained at 5kW of RF power and with 20mTorr Ar. A low plasma potential of less than 26V and a low electron temperature of $2.6{\sim}3.2eV$ could be also obtained. The measured plasma uniformity on the substrate size of 4th generation $(880mm{\times}660mm)$ was about 4%, therefore, it is believed that the multiple linear antennas with U-type parallel connection can be successfully applicable to the large area flat panel display processing.

  • PDF

내·외부고객의 병원선택요인이 병원이미지에 미치는 영향 (The Impact of Hospital Selection Factors between Internal and External Customers on Hospital Image)

  • 이현숙
    • 보건행정학회지
    • /
    • 제23권3호
    • /
    • pp.281-288
    • /
    • 2013
  • Background: The purpose of this study is to grasp the factors forming hospital image and to measure evaluation of internal and external customers towards hospital choice factors. Methods: This study is based 4 types of choice factor such as physical, human, accessibility, and connection. Data were assessed using 98 patients and 96 internal employees who work at A general hospital in Seoul and 116 patients and 97 internal employees at B general hospital in Chunkcheongbuk-do. Data were collected with self-administered questionnaires from February 17 to April 29 in 2012 and analyzed SPSS ver. 18.0 by using frequency, t-test, analysis of variance, correlation, and multiple regression. Results: The results of this study show that factors affecting hospital image is significant different between internal and external customers of hospital A and B. Expecially the finding of this study will be applied to improve connection factors in administrative department of hospital for hospital image. Conclusion: This study presents primary data for correct decision making to authorities of local hospitals that have concern about marketing strategy for hospital image.

Finite element study the seismic behavior of connection to replace the continuity plates in (NFT/CFT) steel columns

  • Rezaifar, Omid;Younesi, Adel
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.73-91
    • /
    • 2016
  • The use of box columns has been increased due to the rigidity in rigid orthogonal moment resisting frames. On the other hand, the installation and welding of necessary horizontal continuity plates inside the columns are both labor-consuming and costly tasks. Accordingly, in this paper, a new beam-to-box column connection by trapezoidal external stiffeners and horizontal bar mats is presented to provide seismic parameters. The proposed connection consists of eight external stiffeners in the level of beam flanges and five horizontal bar mats in Concrete Filled Tube (CFT) columns. The new connection effectively alleviates the stress concentration and moves the plastic hinge away from the column face by horizontal external stiffeners. In addition, the result shows that proposed connection has provided the required strength and rigidity of connection, so that the increased strength, 8.08% and rigidity, 3.01% are compared to connection with internal continuity plates, also the results indicate that this connection can offer appropriate ductility and energy dissipation capacity for its potential application in moment resisting frames in seismic region. As a result, the proposed connection can be a good alternative for connection with continuity plates.

Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

  • Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2019
  • PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

시뮬레이션을 이용한 ATM 교환기 연결 절단율 추정 연구 (The Estimation of Cutoff Connection Rates on the ATM Switching System Using Simulation)

  • 정명기
    • 한국시뮬레이션학회논문지
    • /
    • 제6권2호
    • /
    • pp.117-124
    • /
    • 1997
  • A simulation model for the estimation of cutoff connection rate in the asynchronous transfer mode (ATM) switching system under multimedia traffic environments is presented. The simulator is developed by the integration of the AweSim tool with user-written C++ routines that model the internal structures of operational details of the switching system. For the case study, the simulator is applied to the ATM switching system developed by Electronics and Telecommunications Research Institute (ETRI) to compare design alternatives according to the cutoff connection rates.

  • PDF

치과용 임플란트 시스템의 기계적 가공오차에 관한 연구 (Machining Tolerance of Various Implant Systems and their Components)

  • 김형섭;권긍록;한중석
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.57-65
    • /
    • 2008
  • 연구목적 : 본 연구에서는 rotational freedom을 측정할 수 있는 기구를 개발하여 시중에서 유통되고 있는 국산 임플란트 및 다양한 국적의 임플란트들의 기계적인 가공오차들을 측정하여 다양한 임플란트 시스템의 component간의 기계적인 안정성을 평가하고자 한다. 또한 본 연구에서는 더 나아가 최근에 임플란트 abutment로 각광을 받고 있는 각종 ceramic abutment의 절삭 가공오차에 관한 항목을 측정하여 임플란트 제조사 및 임상의들에게 올바른 정보를 제공하고자 한다. 연구재료 및 방법 : 국내에서 유통되는 외부연결구조의 외국산 임플란트 시스템(Nobel Biocare, Anthorgyr)과 국산 시스템(Neobiotec)과 내부연결구조의 임플란트 시스템(외국산:Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply, 국산:Dentium) 별로 임플란트 fixture, abutment, analog를 서로 교차 연결하여 회전각도측정기(rotational angle measuring device)로 freedom of rotational angle을 측정하였다. 국산 외부연결구조의 지르코니아 abutment(ZirAce)를 외부연결구조의 임플란트 시스템(Neobiotec, Nobel Biocare, Anthorgyr)의 fixture와 analog와 교차연결하여 freedom of rotational angle을 측정하였다. 연구결과 : 국산 외부연결구조의 임플란트 시스템은 약 2.67도(fixture와 abutment 연결시), 내부연결구조의 임플란트는 약 4.3도(fixture와 abutment 연결시)의 rotational freedom을 보였다. 국산 지르코니아 abutment는 외국산 및 국산 외부연결구조 임플란트 시스템과 상관없이 3도 이하(fixture와 연결시)의 결과를 보였다. 결 론 : 시제품으로 제작된 디지털 회전각도측정기는 높은 분해능을 갖고 있었으며, 국산 임플란트의 기계적 가공오차는 외국산 임플란트와 거의 유사했다. 국산 세라믹 abutment의 기계적 가공오차는 fixture 제조회사별로 다르게 나타났지만 같은 회사의 절삭가공된 금속 abutment와 비교시 가공오차가 더 적었다.